Multi-slit prompt-gamma camera for locating of distal dose falloff in proton therapy

被引:2
|
作者
Park, Jong Hoon [1 ]
Kim, Sung Hun [1 ]
Ku, Youngmo [1 ]
Kim, Chan Hyeong [1 ]
Lee, Han Rim [2 ]
Jeong, Jong Hwi [3 ]
Lee, Se Byeong [3 ]
Shin, Dong Ho [4 ]
机构
[1] Hanyang Univ, Dept Nucl Engn, 222 Wangsimni Ro, Seoul 04763, South Korea
[2] Korea Atom Energy Res Inst, Neutron Utilizat Technol Div, Daejeon 34129, South Korea
[3] Natl Canc Ctr, Proton Therapy Ctr, Goyang Si 10408, Gyonggi Do, South Korea
[4] Elect & Telecommun Res Inst, IT Convergence Technol Res Lab, Daejeon 34129, South Korea
关键词
Proton therapy; Prompt gamma; Beam range verification; Distal dose falloff; BEAM RANGE VERIFICATION; COMPTON CAMERA; RADIATION HARDNESS; PENCIL BEAMS; SLIT CAMERA; TARGETS; SYSTEM;
D O I
10.1016/j.net.2019.03.008
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In this research, a multi-slit prompt-gamma camera was developed to locate the distal dose falloff of the proton beam spots in spot scanning proton therapy. To see the performance of the developed camera, therapeutic proton beams were delivered to a solid plate phantom and then the prompt gammas from the phantom were measured using the camera. Our results show that the camera locates the 90% distal dose falloff (= d90%), within about 2-3 mm of error for the spots which are composed 3.8 x 10(8) protons or more. The measured location of d90% is not very sensitive to the irradiation depth of the proton beam (i.e., the depth of proton beam from the phantom surface toward which the camera is located). Considering the number of protons per spot for the most distal spots in typical treatment cases (i.e., 2 Gy dose divided in 2 fields), the camera can locate d90% only for a fraction of the spots depending on the treatment cases. However, the information of those spots is still valuable in that, in the multi-slit prompt-gamma camera, the distal dose falloff of the spots is located solely based on prompt gamma measurement, i.e., not referring to Monte Carlo simulation. (C) 2019 Korean Nuclear Society, Published by Elsevier Korea LLC.
引用
收藏
页码:1406 / 1416
页数:11
相关论文
共 50 条
  • [1] Tackling range uncertainty in proton therapy: Development and evaluation of a new multi-slit prompt-gamma camera (MSPGC) system
    Ku, Youngmo
    Choi, Sehoon
    Cho, Jaeho
    Jang, Sehyun
    Jeong, Jong Hwi
    Kim, Sung Hun
    Cho, Sungkoo
    Kim, Chan Hyeong
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2023, 55 (09) : 3140 - 3149
  • [2] Prompt gamma measurements for locating the dose falloff region in the proton therapy
    Min, Chul-Hee
    Kim, Chan Hyeong
    Youn, Min-Young
    Kim, Jong-Won
    APPLIED PHYSICS LETTERS, 2006, 89 (18)
  • [3] New algorithm to estimate proton beam range for multi-slit prompt- gamma camera
    Ku, Youngmo
    Jung, Jaerin
    Kim, Chan Hyeong
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2022, 54 (09) : 3422 - 3428
  • [4] Sensitivity of a prompt-gamma slit-camera to detect range shifts for proton treatment verification
    Nenoff, Lena
    Priegnitz, Marlen
    Janssens, Guillaume
    Petzoldt, Johannes
    Wohlfahrt, Patrick
    Trezza, Anna
    Smeets, Julien
    Pausch, Guntram
    Richter, Christian
    RADIOTHERAPY AND ONCOLOGY, 2017, 125 (03) : 534 - 540
  • [5] Reducing the risk of proton therapy with prompt-gamma
    Patuleia Venancio, Jose Miguel
    PARTICLES AND NUCLEI INTERNATIONAL CONFERENCE 2021, PANIC2021, 2021,
  • [6] Evaluation of strategies for dose reconstruction from prompt-gamma radiation in proton therapy
    Foglia, B.
    Gianoli, C.
    Masuda, T.
    Bortfeld, T.
    Verburg, J.
    Parodi, K.
    Pinto, M.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1540 - S1542
  • [7] Development of a prompt gamma imaging system with multi-slit collimator and BGO plus SiPM detector for proton therapy monitoring
    Ma, Tianyu
    Fan, Peng
    Lu, Wenzhuo
    Zhang, Hongyang
    Zhang, Debin
    Xia, Yan
    Wang, Shi
    Liu, Yaqiang
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [8] Evaluation of a Novel Multi-slit Collimated Detection System for Prompt Gamma-Ray Imaging During Proton Beam Therapy
    Ellin, J.
    Ready, J.
    Negut, V
    Pak, R.
    Haefner, A.
    Mihailescu, L.
    Vetter, K.
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [9] PROMPT GAMMA IMAGING WITH A SLIT CAMERA FOR REAL TIME RANGE CONTROL IN PROTON THERAPY
    Smeets, J.
    Roellinghoff, F.
    Prieels, D.
    Stichelbaut, F.
    Benilov, A.
    Busca, P.
    Fiorini, C.
    Peloso, R.
    Basilavecchia, M.
    Frizzi, T.
    Dehaes, J. C.
    Dubus, A.
    RADIOTHERAPY AND ONCOLOGY, 2012, 102 : S33 - S34
  • [10] Simulation studies on the correlation of distal dose falloff of a 70-MeV proton beam with a prompt gamma distribution
    Kim, Chan Hyeong
    Min, Chul Hee
    Seo, Kyu Seek
    Kim, Jong-Won
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2007, 50 (05) : 1510 - 1513