Prompt gamma measurements for locating the dose falloff region in the proton therapy

被引:310
|
作者
Min, Chul-Hee
Kim, Chan Hyeong
Youn, Min-Young
Kim, Jong-Won
机构
[1] Hanyang Univ, Dept Nucl Engn, Seoul 133791, South Korea
[2] Seoul Natl Univ, Natl Ctr Inter Univ Res Facil, Seoul 151742, South Korea
[3] Natl Canc Ctr, Dept Biomed Engn, Koyang 411764, Kyonggi, South Korea
关键词
D O I
10.1063/1.2378561
中图分类号
O59 [应用物理学];
学科分类号
摘要
The location of the distal falloff in the proton therapy is an important but often uncertain parameter as different tissue elements are traversed by the beam. A multilayered collimator system has been constructed as a practical means to locate the dose ends by measuring prompt gammas. The collimator is designed to moderate and capture fast neutrons and to prevent unwanted gammas from reaching the scintillation detector. The system has been studied using Monte Carlo technique and has been tested in the beam energy range of 100-200 MeV. Measurements clearly indicated correlations between the gamma distributions and the distal falloff regions. (c) 2006 American Institute of Physics.
引用
下载
收藏
页数:3
相关论文
共 50 条
  • [1] Multi-slit prompt-gamma camera for locating of distal dose falloff in proton therapy
    Park, Jong Hoon
    Kim, Sung Hun
    Ku, Youngmo
    Kim, Chan Hyeong
    Lee, Han Rim
    Jeong, Jong Hwi
    Lee, Se Byeong
    Shin, Dong Ho
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2019, 51 (05) : 1406 - 1416
  • [2] Prompt Gamma Measurements for the Verification of Dose Deposition in Proton Therapy
    Kim, J.
    Kubo, H.
    Tanimori, T.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [3] Simulation studies on the correlation of distal dose falloff of a 70-MeV proton beam with a prompt gamma distribution
    Kim, Chan Hyeong
    Min, Chul Hee
    Seo, Kyu Seek
    Kim, Jong-Won
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2007, 50 (05) : 1510 - 1513
  • [4] Monte Carlo Design Study of a Gamma Detector System to Locate Distal Dose Falloff in Proton Therapy
    Kang, Byung-Hwi
    Kim, Jong-Won
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (01) : 46 - 50
  • [5] Limitations of the Dose Weighted LET Concept for Intensity Modulated Proton Therapy in the Distal Falloff Region and Beyond
    Moskvin, V.
    Pirlepesov, F.
    Stewart, R.
    Farr, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3728 - 3728
  • [6] Evaluation of strategies for dose reconstruction from prompt-gamma radiation in proton therapy
    Foglia, B.
    Gianoli, C.
    Masuda, T.
    Bortfeld, T.
    Verburg, J.
    Parodi, K.
    Pinto, M.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1540 - S1542
  • [7] Reducing the risk of proton therapy with prompt-gamma
    Patuleia Venancio, Jose Miguel
    PARTICLES AND NUCLEI INTERNATIONAL CONFERENCE 2021, PANIC2021, 2021,
  • [8] Prompt gamma detection for range verification in proton therapy
    Kurosawa, Shunsuke
    Kubo, Hidetoshi
    Ueno, Kazuki
    Kabuki, Shigeto
    Iwaki, Satoru
    Takahashi, Michiaki
    Taniue, Kojiro
    Higashi, Naoki
    Miuchi, Kentaro
    Tanimori, Toru
    Kim, Dogyun
    Kim, Jongwon
    CURRENT APPLIED PHYSICS, 2012, 12 (02) : 364 - 368
  • [9] Prompt gamma-ray imaging with a nuclear emulsion for in vivo dose verification in proton therapy
    Toshito, Toshiyuki
    Kimura, Mitsuhiro
    Ogino, Hiroyuki
    Shibamoto, Yuta
    Nakamura, Mitsuhiro
    Sato, Osamu
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [10] Experimentally Optimizing Prompt Gamma Detection for Proton Therapy
    Moteabbed, M.
    Binns, P.
    Flanz, J.
    Paganetti, H.
    Riley, K.
    MEDICAL PHYSICS, 2010, 37 (06)