Prompt gamma measurements for locating the dose falloff region in the proton therapy

被引:310
|
作者
Min, Chul-Hee
Kim, Chan Hyeong
Youn, Min-Young
Kim, Jong-Won
机构
[1] Hanyang Univ, Dept Nucl Engn, Seoul 133791, South Korea
[2] Seoul Natl Univ, Natl Ctr Inter Univ Res Facil, Seoul 151742, South Korea
[3] Natl Canc Ctr, Dept Biomed Engn, Koyang 411764, Kyonggi, South Korea
关键词
D O I
10.1063/1.2378561
中图分类号
O59 [应用物理学];
学科分类号
摘要
The location of the distal falloff in the proton therapy is an important but often uncertain parameter as different tissue elements are traversed by the beam. A multilayered collimator system has been constructed as a practical means to locate the dose ends by measuring prompt gammas. The collimator is designed to moderate and capture fast neutrons and to prevent unwanted gammas from reaching the scintillation detector. The system has been studied using Monte Carlo technique and has been tested in the beam energy range of 100-200 MeV. Measurements clearly indicated correlations between the gamma distributions and the distal falloff regions. (c) 2006 American Institute of Physics.
引用
收藏
页数:3
相关论文
共 50 条
  • [21] Comparison of Prompt Gamma and PET Imaging for Range Verification in Proton Therapy
    Moteabbed, M.
    Espana, S.
    Paganetti, H.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [22] Non-radioactive elements for prompt gamma enhancement in proton therapy
    Galanakou, Panagiota
    Leventouri, Theodora
    Muhammad, Wazir
    RADIATION PHYSICS AND CHEMISTRY, 2022, 196
  • [23] Stable Isotopes as Prompt Gamma Rays Enhancement Agents in Proton Therapy
    Galanakou, P.
    Leventouri, T.
    Muhammad, W.
    MEDICAL PHYSICS, 2022, 49 (06) : E704 - E704
  • [24] Progress towards a semiconductor Compton camera for prompt gamma imaging during proton beam therapy for range and dose verification
    Gutierrez, A.
    Baker, C.
    Boston, H.
    Chung, S.
    Judson, D. S.
    Kacperek, A.
    Le Crom, B.
    Moss, R.
    Royle, G.
    Speller, R.
    Boston, A. J.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [25] TWO-DIMENSIONAL PROMPT GAMMA MEASUREMENT SIMULATION FOR IN VIVO DOSE VERIFICATION IN PROTON THERAPY: A MONTE CARLO STUDY
    Min, Chul Hee
    Lee, Han Rim
    Kim, Chan Hyeong
    NUCLEAR TECHNOLOGY, 2011, 175 (01) : 11 - 15
  • [26] Deep Learning Based 3D Dose Estimation from Prompt Gamma Distribution for Proton Therapy Monitoring
    Lu, Wenzhuo
    Ma, Tianyu
    Yang, Tao
    Xu, Shouping
    Liu, Yaqiang
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [27] Dose Measurements at Provision Proton Therapy Center
    Burahmah, Naser
    Heilbronn, Lawrence
    HEALTH PHYSICS, 2024, 126 (04): : 252 - 258
  • [28] Dose profile monitoring with carbon ions by means of prompt-gamma measurements
    Testa, E.
    Bajard, M.
    Chevallier, M.
    Dauvergne, D.
    Le Foulher, F.
    Freud, N.
    Letang, J. M.
    Poizat, J. C.
    Ray, C.
    Testa, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2009, 267 (06): : 993 - 996
  • [29] Prompt Gamma Spectroscopy of Metallic Implants in Proton Therapy: A Monte Carlo Study
    Liu, C.
    MEDICAL PHYSICS, 2020, 47 (06) : E833 - E833
  • [30] Spectroscopic study of prompt-gamma emission for range verification in proton therapy
    Kelleter, Laurent
    Wronska, Aleksandra
    Besuglow, Judith
    Konefal, Adam
    Laihem, Karim
    Leidner, Johannes
    Magiera, Andrzej
    Parodi, Katia
    Rusiecka, Katarzyna
    Stahl, Achim
    Tessonnier, Thomas
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 34 : 7 - 17