Validation of a new noninvasive method to measure blood pressure and assess baroreflex sensitivity in preterm infants during sleep

被引:30
|
作者
Yiallourou, Stephanie R. [1 ]
Walker, Adrian M. [1 ]
Horne, Rosemary S. C. [1 ]
机构
[1] Monash Univ, Monash Inst Med Res, Ritchie Ctr Baby Hlth Res, Melbourne, Vic 3004, Australia
关键词
blood pressure; baroreflex; sleep; cardiovascular control;
D O I
10.1093/sleep/29.8.1083
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Objectives: Accuracy and precision of a noninvasive device for continuously measuring blood pressure (BP) (Finometer (TM), FMS, The Netherlands) during sleep was assessed in preterm infants. Design: Absolute BP beat-to-beat values, interbeat changes, measurement precision, and baroreflex sensitivity were compared with BP measurements from intraarterial catheters. Participants: Ten preterm infants (gestational age 27-36 weeks; birth weight 964-2620 gm) were studied in the neonatal intensive care unit. Measurements and Results: The 2 modes of BP measurement were compared in 2-minute epochs (n = 10-12/infant). Mean arterial pressure, systolic arterial pressure, and diastolic arterial pressure were analyzed beat to beat, and baroreflex sensitivity was assessed using spontaneous sequence analysis. Mean differences for absolute BP (mm Hg) were as follows: mean arterial pressure, 3 (limits of agreement, -1 to 8); systolic arterial pressure, -4 (-8 to 1); and diastolic arterial pressure, 7 (4 to 10). Mean differences and limits of agreement for interbeat changes were essentially 0 for mean arterial pressure, systolic arterial pressure, and diastolic arterial pressure. Precision ( 95% confidence intervals, mm Hg) for the Finometer (TM) were mean arterial pressure +/- 7, systolic arterial pressure 8, and diastolic arterial pressure +/- 6. Precision was greater for the arterial catheter (mean arterial pressure 3, systolic arterial pressure 4, and diastolic arterial pressure 4). Baroreflex sensitivity calculated from the Finometer (TM) BP was (mean +/- SEM, ms/mm Hg) 1.74 +/- 0.23 and, from the catheter system, BP was 1.56 +/- 0.21 (p value NS). Conclusions: The Finometer (TM) provides accurate measurements of beat-to-beat BP and baroreflex sensitivity. The ability to continuously measure BP and baroreflex sensitivity during sleep in infants may provide vital clues into pathologic conditions associated with impaired autonomic control during sleep.
引用
收藏
页码:1083 / 1088
页数:6
相关论文
共 50 条
  • [1] A New Noninvasive Method To Assess Adrenergic Baroreflex Sensitivity
    Singer, Wolfgang
    Low, Phillip
    NEUROLOGY, 2009, 72 (11) : A447 - A447
  • [2] A noninvasive measure of baroreflex sensitivity without blood pressure measurement
    Davies, LC
    Colhoun, H
    Coats, AJS
    Piepoli, M
    Francis, DP
    AMERICAN HEART JOURNAL, 2002, 143 (03) : 441 - 447
  • [3] BAROREFLEX SENSITIVITY(BRS) DURING SLEEP STATES IN PRETERM INFANTS 253
    Véronique Gournay
    Sylvie Nguyen The Tich
    Emmanuel Drouin
    Jean Christophe Rozé
    Pediatric Research, 1997, 41 (Suppl 4) : 45 - 45
  • [4] Noninvasive Assessment of Blood Pressure Variability in Preterm Infants
    Peter Andriessen
    Rick L M Schoffelen
    Ralph C M Berendsen
    Nicole A M de Beer
    S Guid Oei
    Pieter F F Wijn
    Carlos E Blanco
    Pediatric Research, 2004, 55 : 220 - 223
  • [5] Noninvasive assessment of blood pressure variability in preterm infants
    Andriessen, P
    Schoffelen, RLM
    Berendsen, RCM
    De Beer, NAM
    Oei, SG
    Wijn, PFF
    Blanco, CE
    PEDIATRIC RESEARCH, 2004, 55 (02) : 220 - 223
  • [6] Baroreflex Sensitivity During Sleep in Infants: Impact of Sleeping Position and Sleep State
    Yiallourou, Stephanie R.
    Sands, Scott A.
    Walker, Adrian M.
    Horne, Rosemary S. C.
    SLEEP, 2011, 34 (06) : 725 - 732
  • [7] A new noninvasive method to measure blood pressure - Results of a multicenter trial
    Belani, K
    Ozaki, M
    Hynson, J
    Hartmann, T
    Reyford, H
    Martino, JM
    Poliac, M
    Miller, R
    ANESTHESIOLOGY, 1999, 91 (03) : 686 - 692
  • [8] New method to measure and improve consistency of baroreflex sensitivity values
    Bernardi, Luciano
    De Barbieri, Giacomo
    Rosengard-Barlund, Milla
    Makinen, Ville-Petteri
    Porta, Cesare
    Groop, Per-Henrik
    CLINICAL AUTONOMIC RESEARCH, 2010, 20 (06) : 353 - 361
  • [9] REFLEX REGULATION OF ARTERIAL PRESSURE DURING SLEEP IN MAN - A QUANTITATIVE METHOD OF ASSESSING BAROREFLEX SENSITIVITY
    SMYTH, HS
    SLEIGHT, P
    PICKERING, GW
    CIRCULATION RESEARCH, 1969, 24 (01) : 109 - +
  • [10] New method to measure and improve consistency of baroreflex sensitivity values
    Luciano Bernardi
    Giacomo De Barbieri
    Milla Rosengård-Bärlund
    Ville-Petteri Mäkinen
    Cesare Porta
    Per-Henrik Groop
    Clinical Autonomic Research, 2010, 20 : 353 - 361