Rapid evaluation of FDG imaging alternatives using head-to-head comparisons of full ring and gamma camera based PET scanners -: a systematic review

被引:4
|
作者
Haslinghuis-Bajan, LM
Hooft, L
van Lingen, A
van Tulder, M
Devillé, W
Mijnhout, GS
Teule, GJJ
Hoekstra, OS
机构
[1] Vrije Univ Amsterdam, Med Ctr, Dept Nucl Med, NL-1007 MB Amsterdam, Netherlands
[2] Vrije Univ Amsterdam, Med Ctr, Dept Clin Epidemiol & Biostat, NL-1007 MB Amsterdam, Netherlands
[3] Vrije Univ Amsterdam, Med Ctr, Inst Res Extramural Med, NL-1007 MB Amsterdam, Netherlands
来源
NUKLEARMEDIZIN-NUCLEAR MEDICINE | 2002年 / 41卷 / 05期
关键词
PET; coincidence detection; F-18-FDG; neoplasma;
D O I
10.1055/s-0038-1625288
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim: While FDG full ring PET (FRPET) has been gradually accepted in oncology, the role of the cheaper gamma camera based alternatives (GCPET) is less clear. Since technology is evolving rapidly, "tracker trials" would be most helpful to provide a first approximation of the relative merits of these alternatives. As difference in scanner sensitivity is the key variable, head-to-head comparison with FRPET is an attractive study design. This systematic review summarises such studies. Methods: Nine studies were identified until July 1, 2000. Two observers assessed the methodological quality (Cochrane criteria), and extracted data. Results: The studies comprised a variety of tumours and indications. The reported GC- and FRPET agreement for detection of malignant lesions ranged from 55 to 100%, but with methodological limitations (blinding, standardisation, limited patient spectrum). Mean lesion diameter was 2.9 cm (SD 1.8), with only about 20% <1.5 cm. The 3 studies with the highest quality reported concordances of 74-79%, for the studied lesion spectrum. Contrast at GCPET was lower than that of FRPET, contrast and detection agreement were positively related. Logistic regression analysis suggested that pre-test indicators might be used to predict FRPET-GCPET concordance. Conclusion: In spite of methodological limitations, "first generation" GCPET devices detected sufficient FRPET positive lesions to allow prospective evaluation in clinical situations where the impact of FRPET is not confined to detection of small lesions (<1.5 cm). The efficiency of head-to-head comparative studies would benefit from application in a clinically relevant patient spectrum, with proper blinding and standardisation of acquisition procedures.
引用
收藏
页码:208 / 213
页数:6
相关论文
共 50 条
  • [1] Head-to-head comparison of full ring and gamma camera based PET scanners: A systematic review
    Haslinghuis-Bajan, LM
    Hooft, L
    Van Lingen, A
    Van Tulder, M
    Deville, W
    Mijnhout, GS
    Hoekstra, OS
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (08): : 1080 - 1080
  • [2] Head-to-Head Comparison of FDG and Radiolabeled FAPI PET: A Systematic Review of the Literature
    Guglielmo, Priscilla
    Alongi, Pierpaolo
    Baratto, Lucia
    Abenavoli, Elisabetta
    Buschiazzo, Ambra
    Celesti, Greta
    Conte, Miriam
    Filice, Rossella
    Gorica, Joana
    Jonghi-Lavarini, Lorenzo
    Lanzafame, Helena
    Laudicella, Riccardo
    Librando, Maria
    Linguanti, Flavia
    Mattana, Francesco
    Miceli, Alberto
    Olivari, Laura
    Piscopo, Leandra
    Romagnolo, Cinzia
    Santo, Giulia
    Vento, Antonio
    Volpe, Fabio
    Evangelista, Laura
    LIFE-BASEL, 2023, 13 (09):
  • [3] PET imaging using a triple-head gamma camera
    Kuikka, JT
    Sohlberg, A
    Husso-Saastamoinen, M
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2002, 22 (05) : 328 - 331
  • [4] FAPI PET versus FDG PET, CT or MRI for Staging Pancreatic-, Gastric- and Cholangiocarcinoma: Systematic Review and Head-to-Head Comparisons of Diagnostic Performances
    Veldhuijzen van Zanten, Sophie E. M.
    Pieterman, Kay J.
    Wijnhoven, Bas P. L.
    Pruis, Ilanah J.
    Groot Koerkamp, Bas
    van Driel, Lydi M. J. W.
    Verburg, Frederik A.
    Thomeer, Maarten G. J.
    DIAGNOSTICS, 2022, 12 (08)
  • [5] Staging of esophageal cancer using PET/MRI: a systematic review with head-to-head comparison
    Mohebbi, Alisa
    Mohammadzadeh, Saeed
    Moradi, Zahra
    Mohammadi, Afshin
    Poustchi, Hossein
    Tavangar, Seyed Mohammad
    BMC MEDICAL IMAGING, 2025, 25 (01):
  • [6] Head-to-Head Comparison of the Diagnostic Performance of FDG PET/CT and FDG PET/MRI in Patients With Cancer: A Systematic Review and Meta-Analysis
    Singnurkar, Amit
    Poon, Raymond
    Metser, Ur
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2024, 223 (03)
  • [7] Head-to-Head Comparison between Peptide-Based Radiopharmaceutical for PET and SPECT in the Evaluation of Neuroendocrine Tumors: A Systematic Review
    Poletto, Giulia
    Cecchin, Diego
    Sperti, Stefania
    Filippi, Luca
    Realdon, Nicola
    Evangelista, Laura
    CURRENT ISSUES IN MOLECULAR BIOLOGY, 2022, 44 (11) : 5516 - 5530
  • [8] Dual head coincidence gamma camera FDG imaging: Comparison with FOG PET in oncologic diagnosis
    Shreve, PD
    Steventon, RS
    Deters, E
    Gross, MD
    Wahl, RL
    RADIOLOGY, 1997, 205 : 341 - 341
  • [9] Feasibility of fluorodeoxyglucose dual-head gamma camera coincidence imaging in the evaluation of lung cancer: Comparison with FDG PET
    Tatsumi, M
    Yutani, K
    Watanabe, Y
    Miyoshi, S
    Tomiyama, N
    Johkoh, T
    Kusuoka, H
    Nakamura, H
    Nishimura, T
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (04) : 566 - 573
  • [10] F-18-FDG PET using a dual-head gamma camera in head and neck tumors.
    Pai, MS
    Park, CH
    Koh, JW
    Suh, JH
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 237P - 238P