Rapid evaluation of FDG imaging alternatives using head-to-head comparisons of full ring and gamma camera based PET scanners -: a systematic review

被引:4
|
作者
Haslinghuis-Bajan, LM
Hooft, L
van Lingen, A
van Tulder, M
Devillé, W
Mijnhout, GS
Teule, GJJ
Hoekstra, OS
机构
[1] Vrije Univ Amsterdam, Med Ctr, Dept Nucl Med, NL-1007 MB Amsterdam, Netherlands
[2] Vrije Univ Amsterdam, Med Ctr, Dept Clin Epidemiol & Biostat, NL-1007 MB Amsterdam, Netherlands
[3] Vrije Univ Amsterdam, Med Ctr, Inst Res Extramural Med, NL-1007 MB Amsterdam, Netherlands
来源
NUKLEARMEDIZIN-NUCLEAR MEDICINE | 2002年 / 41卷 / 05期
关键词
PET; coincidence detection; F-18-FDG; neoplasma;
D O I
10.1055/s-0038-1625288
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim: While FDG full ring PET (FRPET) has been gradually accepted in oncology, the role of the cheaper gamma camera based alternatives (GCPET) is less clear. Since technology is evolving rapidly, "tracker trials" would be most helpful to provide a first approximation of the relative merits of these alternatives. As difference in scanner sensitivity is the key variable, head-to-head comparison with FRPET is an attractive study design. This systematic review summarises such studies. Methods: Nine studies were identified until July 1, 2000. Two observers assessed the methodological quality (Cochrane criteria), and extracted data. Results: The studies comprised a variety of tumours and indications. The reported GC- and FRPET agreement for detection of malignant lesions ranged from 55 to 100%, but with methodological limitations (blinding, standardisation, limited patient spectrum). Mean lesion diameter was 2.9 cm (SD 1.8), with only about 20% <1.5 cm. The 3 studies with the highest quality reported concordances of 74-79%, for the studied lesion spectrum. Contrast at GCPET was lower than that of FRPET, contrast and detection agreement were positively related. Logistic regression analysis suggested that pre-test indicators might be used to predict FRPET-GCPET concordance. Conclusion: In spite of methodological limitations, "first generation" GCPET devices detected sufficient FRPET positive lesions to allow prospective evaluation in clinical situations where the impact of FRPET is not confined to detection of small lesions (<1.5 cm). The efficiency of head-to-head comparative studies would benefit from application in a clinically relevant patient spectrum, with proper blinding and standardisation of acquisition procedures.
引用
收藏
页码:208 / 213
页数:6
相关论文
共 50 条
  • [31] Evaluation of the Prognostic Value of FDG PET/CT Parameters for Patients With Surgically Treated Head and Neck Cancer: A Systematic Review
    Creff, Gwenaelle
    Devillers, Anne
    Depeursinge, Adrien
    Palard-Novello, Xavier
    Acosta, Oscar
    Jegoux, Franck
    Castelli, Joel
    JAMA OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2020, 146 (05) : 471 - 479
  • [32] Head-to-head comparison between 18F-FDG PET/low-dose CT and 18F-FDG PET/contrast-enhanced CT in relapsing ovarian carcinoma: a systematic review and meta-analysis
    Massollo, Michela
    Treglia, Giorgio
    Trimboli, Pierpaolo
    Fiz, Francesco
    Ugolini, Martina
    Piccardo, Arnoldo
    CLINICAL AND TRANSLATIONAL IMAGING, 2021, 9 (01) : 73 - 81
  • [33] Head-to-head comparison between 18F-FDG PET/low-dose CT and 18F-FDG PET/contrast-enhanced CT in relapsing ovarian carcinoma: a systematic review and meta-analysis
    Michela Massollo
    Giorgio Treglia
    Pierpaolo Trimboli
    Francesco Fiz
    Martina Ugolini
    Arnoldo Piccardo
    Clinical and Translational Imaging, 2021, 9 : 73 - 81
  • [34] Head-to-Head Comparison between 18F-FES PET/CT and 18F-FDG PET/CT in Oestrogen Receptor-Positive Breast Cancer: A Systematic Review and Meta-Analysis
    Piccardo, Arnoldo
    Fiz, Francesco
    Treglia, Giorgio
    Bottoni, Gianluca
    Trimboli, Pierpaolo
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (07)
  • [35] Head-to-head comparison of [68Ga]Ga-FAPI PET and [18F]FDG PET in the detection of bone and lymph node metastasis in various cancers: A systematic review and meta-analysis
    Wu, Guiyou
    Wang, Daofeng
    Zhang, Wupeng
    Jia, Zhengfeng
    Li, Jiantao
    Zhang, Licheng
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 171
  • [36] A systematic performance evaluation of head motion correction techniques for3 commercial PET scanners using a reproducible experimental acquisition protocol
    Inomata, Takato
    Watanuki, Shoichi
    Odagiri, Hayato
    Nambu, Takeyuki
    Karakatsanis, Nicolas A.
    Ito, Hiroshi
    Watabe, Hiroshi
    Tashiro, Manabu
    Shidahara, Miho
    ANNALS OF NUCLEAR MEDICINE, 2019, 33 (07) : 459 - 470
  • [37] Evaluation of an adrenal mass in a patient with lung cancer by FDG coincidence positron emission tomography using a dual-head gamma camera
    Pai, MS
    Park, CH
    Yoon, SN
    Kim, S
    Whang, KH
    CLINICAL NUCLEAR MEDICINE, 2000, 25 (11) : 924 - 925
  • [38] Comparative impact of standard approach, FDG PET and FDG dual-head coincidence gamma camera imaging in preoperative staging of patients with non-small-cell lung cancer
    Delahaye, N
    Crestani, B
    Rakotonirina, H
    Lebtahi, R
    Sarda, L
    Girard, P
    Charpentier, E
    Fery-Lemonnier, E
    Syrota, A
    Aubier, M
    LE Guludec, D
    Fdg, FP
    NUCLEAR MEDICINE COMMUNICATIONS, 2003, 24 (12) : 1215 - 1224
  • [39] F-18FDG imaging with coincidence dual-head gamma camera (Co-PET) in diagnosis, staging and management of lung cancer.
    Lin, PC
    Chu, JM
    Pocock, N
    Quach, T
    Sorensen, B
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 135P - 135P
  • [40] Evaluation of pulmonary nodules: comparison of a prototype dual crystal (LSO/NAI) dual head coincidence camera and full ring positron emission tomography (PET)
    Joshi, U
    Raijmakers, PGHM
    van Lingen, A
    Comans, EFI
    Pijpers, R
    Teule, GJJ
    Hoekstra, OS
    EUROPEAN JOURNAL OF RADIOLOGY, 2005, 55 (02) : 250 - 254