PET imaging using a triple-head gamma camera

被引:3
|
作者
Kuikka, JT [1 ]
Sohlberg, A
Husso-Saastamoinen, M
机构
[1] Kuopio Univ Hosp, Dept Clin Physiol & Nucl Med, FIN-70210 Kuopio, Finland
[2] Univ Kuopio, FIN-70211 Kuopio, Finland
[3] Niuvanniemi Hosp, Kuopio, Finland
关键词
coincidence imaging; fluorodeoxyglucose; gamma camera; physical performance;
D O I
10.1046/j.1475-097X.2002.00439.x
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Interest in clinical fluorodeoxyglucose (FDG) imaging with multiple-head gamma cameras is growing. To improve sensitivity, triple-head coincidence imaging has been proposed. We report our initial experiences with a triple-head coincidence gamma camera with 19 mm sodium iodide crystal thickness. Several positron emission tomography-image quality parameters were evaluated using a Carlson and line source phantom. The system sensitivity with two-dimensional axial shields was 830 cps kBq(-1) ml(-1) and maximum noise equivalent count rate 1900 cps for an F-18-activity of 50 MBq. The imaging resolution was in central axial 7.0 mm and in central transaxial 7.6 mm, respectively. The average scatter fraction in scattered media was 29%. Clinical brain, heart and whole body images studies with [F-18]FDG were acquired and they show good correlation with the phantom image quality. As a conclusion, triple-head coincidence gamma camera provides relatively high-count rate imaging with good contrast and resolution.
引用
收藏
页码:328 / 331
页数:4
相关论文
共 50 条
  • [1] Triple-head gamma camera PET: system overview and performance characteristics
    Grosev, D
    Loncaric, S
    Vandenberghe, S
    Dodig, D
    NUCLEAR MEDICINE COMMUNICATIONS, 2002, 23 (08) : 809 - 814
  • [2] Randoms distributions for triple-head gamma-camera PET systems
    Kolthammer, JA
    Matthews, CG
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1185 - 1189
  • [3] Conicidence PET with triple-head gamma camera using F-18FDG in oncolgy
    Oresic, B.
    Grosev, D.
    Jurasinovic, Z.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S380 - S380
  • [4] Cone-beam SPECT brain imaging using helical orbit and triple-head gamma camera: optimization studies
    Vogelsang, L.
    Krol, A.
    Lipson, E.
    Feiglin, D.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S388 - S388
  • [5] Triple-head coincidence imaging
    Matthews, CG
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 907 - 909
  • [6] A Monte Carlo simulation study to evaluate septal spacing using triple-head hybrid PET imaging
    Groiselle, CJ
    D'Asseler, Y
    Kolthammer, JA
    Matthews, CG
    Glick, SJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) : 1339 - 1346
  • [7] Evaluation of spatial resolution and image contrast of a triple-head gamma camera with coincidence detection.
    Bonniaud, G
    Petegnief, Y
    Grahek, D
    Talbot, JN
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 227P - 227P
  • [8] A Monte-Carlo simulation study to evaluate septal spacing using triple-head hybrid PET imaging
    Groiselle, CJ
    Kolthammer, JA
    Matthews, CG
    Glick, SJ
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1190 - 1194
  • [9] Optimization of SPECT imaging performance of a triple-head gamma camera with combined cone- and fan-beam collimators and circular orbit acquisition for brain imaging
    Vogelsang, Levon
    Krol, Andrzej
    Lipson, Edward
    Feiglin, David
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [10] Pulmonary scintigraphy with a triple-head camera for evaluation of acute pulmonary embolism
    Gerard S.K.
    Hsu T.-C.
    Harrison C.
    Emergency Radiology, 1999, 6 (1) : 17 - 23