Interest in clinical fluorodeoxyglucose (FDG) imaging with multiple-head gamma cameras is growing. To improve sensitivity, triple-head coincidence imaging has been proposed. We report our initial experiences with a triple-head coincidence gamma camera with 19 mm sodium iodide crystal thickness. Several positron emission tomography-image quality parameters were evaluated using a Carlson and line source phantom. The system sensitivity with two-dimensional axial shields was 830 cps kBq(-1) ml(-1) and maximum noise equivalent count rate 1900 cps for an F-18-activity of 50 MBq. The imaging resolution was in central axial 7.0 mm and in central transaxial 7.6 mm, respectively. The average scatter fraction in scattered media was 29%. Clinical brain, heart and whole body images studies with [F-18]FDG were acquired and they show good correlation with the phantom image quality. As a conclusion, triple-head coincidence gamma camera provides relatively high-count rate imaging with good contrast and resolution.
引用
收藏
页码:328 / 331
页数:4
相关论文
共 50 条
  • [31] A data acquisition system for coincidence imaging using a conventional dual head gamma camera
    Lewellen, TK
    Miyaoka, RS
    Jansen, F
    Kaplan, MS
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) : 1214 - 1218
  • [32] Cardiac imaging with gamma camera coincidence (hybrid) PET.
    Smith, MF
    Brown, BP
    Driver, DR
    Dilsizian, V
    Schraml, FV
    Carson, JM
    Bacharach, SL
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 178P - 178P
  • [33] Physical evaluation of 511 keV imaging with gamma camera and PET
    Vandenberghe, S
    D'Asseler, Y
    Koole, M
    Monsieurs, M
    Van de Walle, R
    Lemahieu, I
    Dierckx, RA
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1057 - 1061
  • [34] F-18-FDG PET using a dual-head gamma camera in head and neck tumors.
    Pai, MS
    Park, CH
    Koh, JW
    Suh, JH
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 237P - 238P
  • [35] The use of noise equivalent count rates for optimisation of FDG imaging using gamma camera PET
    Visvikis, D
    Fryer, TD
    Downey, S
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (09): : 1184 - 1184
  • [36] PET imaging using gamma cameras
    D'Asseler, Y
    Vandenberghe, S
    De Winter, F
    Van de Walle, R
    Koole, M
    Bouwens, L
    Lemahieu, I
    Dierckx, RA
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2001, 25 (02) : 87 - 96
  • [37] Investigation of Noise Equivalent Count rate in positron imaging using a dual head gamma camera
    Brasse, D
    Tararine, M
    Lamer, O
    Bendriem, B
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 1223 - 1227
  • [38] Investigation of noise equivalent count rate in positron imaging using a dual head gamma camera
    Brasse, D
    Tararine, M
    Lamer, O
    Bendriem, B
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 438 - 442
  • [39] FDG PET and dual-head gamma camera positron coincidence detection imaging of suspected malignancies and brain disorders
    Delbeke, D
    Patton, JA
    Martin, WH
    Sandler, MP
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (01) : 110 - 117
  • [40] Feasibility of fluorodeoxyglucose dual-head gamma camera coincidence imaging in the evaluation of lung cancer: Comparison with FDG PET
    Tatsumi, M
    Yutani, K
    Watanabe, Y
    Miyoshi, S
    Tomiyama, N
    Johkoh, T
    Kusuoka, H
    Nakamura, H
    Nishimura, T
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (04) : 566 - 573