Scatter correction method for X-ray CT using primary modulation: Theory and preliminary results

被引:192
|
作者
Zhu, Lei [1 ]
Bennett, N. Robert
Fahrig, Rebecca
机构
[1] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
关键词
cone-beam CT; primary modulation; scatter correction; X-ray scatter;
D O I
10.1109/TMI.2006.884636
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
An X-ray system with a large area detector has high scatter-to-primary ratios (SPRs), which result in severe artifacts in reconstructed computed tomography (CT) images. A scatter correction algorithm is introduced that provides effective scatter correction but does not require additional patient exposure. The key hypothesis of the algorithm is that the high-frequency components of the X-ray spatial distribution do not result in strong high-frequency signals in the scatter. A calibration sheet with a checkerboard pattern of semitransparent blockers (a "primary modulator") is inserted between the X-ray source and the object. The primary distribution is partially modulated by a high-frequency function, while the scatter distribution still has dominant low-frequency components, based on the hypothesis. Filtering and demodulation techniques suffice to extract the low-frequency components of the primary and hence obtain the scatter estimation. The hypothesis was validated using Monte Carlo (MC) simulation, and the algorithm was evaluated by both MC simulations and physical experiments. Reconstructions of a software humanoid phantom suggested system parameters in the physical implementation and showed that the proposed method reduced the relative mean square error of the reconstructed image in the central region of interest from 74.2% to below 1%. In preliminary physical experiments on the standard evaluation phantom, this error was reduced from 31.8% to 2.3%, and it was also demonstrated that the algorithm has no noticeable impact on the resolution of the reconstructed image in spite of the filter-based approach. Although the proposed scatter correction technique was implemented for X-ray CT, it can also be used in other X-ray imaging applications, as long as a primary modulator can be inserted between the X-ray source and the imaged object.
引用
收藏
页码:1573 / 1587
页数:15
相关论文
共 50 条
  • [1] Scatter Correction Method by Temporal Primary Modulation in X-Ray CT
    Schoerner, Karsten
    Goldammer, Matthias
    Stierstorfer, Karl
    Stephan, Juergen
    Boeni, Peter
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (06) : 3278 - 3285
  • [2] Scatter correction method for x-ray CT using primary modulation: Phantom studies
    Gao, Hewei
    Fahrig, Rebecca
    Bennett, N. Robert
    Sun, Mingshan
    Star-Lack, Josh
    Zhu, Lei
    MEDICAL PHYSICS, 2010, 37 (02) : 934 - 946
  • [3] Virtual scatter modulation for X-ray CT scatter correction using primary modulator
    Gao, Hewei
    Zhu, Lei
    Fahrig, Rebecca
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2017, 25 (06) : 869 - 885
  • [4] Improved scatter correction for X-ray conebeam CT using primary modulation
    Zhu, Lei
    StarLack, Josh
    Bennett, N. Robert
    Li, Tianfang
    Xing, Lei
    Fahrig, Rebecca
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [5] Evaluation of an Erbium Modulator in X-ray Scatter Correction Using Primary Modulation
    Gao, Hewei
    Niu, Tianye
    Zhu, Lei
    Fahrig, Rebecca
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [6] Modulator design for x-ray scatter correction using primary modulation: Material selection
    Gao, Hewei
    Zhu, Lei
    Fahrig, Rebecca
    MEDICAL PHYSICS, 2010, 37 (08) : 4029 - 4037
  • [7] Scatter Correction for X-ray Imaging Using Primary Modulation: A Phantom Study for CBCT
    Zhu, Lei
    Bennett, Robert
    Fahrig, Rebecca
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1372 - +
  • [8] Analysis of primary modulation based x-ray scatter correction methods
    Horvath, Aron
    Hadhazi, Daniel
    Horvath, Gabor
    MEDICAL PHYSICS, 2016, 43 (11) : 5794 - 5807
  • [9] Optimization of System Parameters for Modulator Design in X-ray Scatter Correction Using Primary Modulation
    Gao, Hewei
    Zhu, Lei
    Fahrig, Rebecca
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [10] An analysis of scatter characteristics in x-ray CT spectral correction
    Zhang, Tao
    Chen, Zhiqiang
    Zhou, Hao
    Bennett, N. Robert
    Wang, Adam S.
    Gao, Hewei
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (07):