An amperometric glucose biosensor based on a MnO2/graphene composite modified electrode

被引:43
|
作者
Liu, Yuge [1 ]
Zhang, Xiumei [1 ]
He, Dongning [2 ]
Ma, Feiyue [1 ]
Fua, Qiong [1 ]
Hu, Yun [3 ]
机构
[1] Chinese Acad Trop Agr Sci, South Subtrop Crop Res Inst, Key Lab Trop Fruit Biol, Minist Agr, Zhanjiang 524091, Peoples R China
[2] Univ So Queensland, Ctr Excellence Engineered Fibre Composites, Toowoomba, Qld 4350, Australia
[3] China Tobacco Guizhou Ind Co Ltd, Ctr Technol, Guiyang 550002, Peoples R China
基金
中国国家自然科学基金;
关键词
DIRECT ELECTROCHEMISTRY; OXIDASE; GRAPHENE; NANOPARTICLES; IMMOBILIZATION; HEMOGLOBIN; NAFION; FILM; PERFORMANCE;
D O I
10.1039/c6ra02680j
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this paper, a novel composite of graphene/MnO2 (GR/MnO2) was successfully synthesized by a simple one-step hydrothermal method. The as-synthesized MnO2 and the composite were characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS) and Fourier transform infrared spectroscopy (FTIR). The results showed that MnO2 was nanorods and the two materials were perfectly composited. The composite was decorated on a glassy carbon electrode (GCE) and used for the entrapment of glucose oxidase (GOD). Electrochemical results showed that the composite modified electrode showed a pair of well-defined redox peaks, and the direct electron transfer between GOD and the electrode surface was accelerated. The sensor fabricated by the composite modified electrode showed an excellent response to the oxidation of glucose with a wide linear range (0.04 to 2 mM), low detection limit (10 mM), and high sensitivity (3.3 mu A mM(-1) cm(-2)). The sensor also exhibited excellent reproducibility, stability and selectivity, and it can be used in the determination of glucose in real samples.
引用
收藏
页码:18654 / 18661
页数:8
相关论文
共 50 条
  • [31] Study on the amperometric glucose biosensor based on tin oxide electrode
    Liao, Cheng-Wei
    Chou, Jung-Chuan
    Sun, Tai-Ping
    Hsiung, Shen-Kan
    Hsieh, Jui-Hsiang
    RARE METAL MATERIALS AND ENGINEERING, 2006, 35 : 291 - 294
  • [32] An amperometric glucose biosensor based on the immobilization of glucose oxidase on the platinum electrode modified with NiO doped ZnO nanorods
    Chu, Xiangfeng
    Zhu, Xiaohua
    Dong, Yongping
    Chen, Tongyun
    Ye, Mingfu
    Sun, Wenqi
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2012, 676 : 20 - 26
  • [33] Amperometric glucose biosensor based on adsorption of glucose oxidase at platinum nanoparticle-modified carbon nanotube electrode
    Tang, H
    Chen, JH
    Yao, SZ
    Nie, LH
    Deng, GH
    Kuang, YF
    ANALYTICAL BIOCHEMISTRY, 2004, 331 (01) : 89 - 97
  • [34] Electrochemical Synthesis of Graphene/MnO2 Nano-Composite for Application to Supercapacitor Electrode
    Jeong, Kwang Ho
    Lee, Hyeon Jeong
    Simpson, Michael F.
    Jeong, Sang Mun
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2016, 16 (05) : 4620 - 4625
  • [35] Effect of Reducing Agent on Preparation and Electroactivity of MnO2/Graphene Composite Electrode for Capacitors
    Byun, Sang-Chul
    Jung, Yongju
    Kim, Seok
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2018, 18 (10) : 7128 - 7131
  • [36] Amperometric determination of bonded glucose with an MnO2 and glucose oxidase bulk-modified screen-printed electrode using flow-injection analysis
    Turkusic, E
    Kalcher, J
    Kahrovic, E
    Beyene, NW
    Moderegger, H
    Sofic, E
    Begic, S
    Kalcher, K
    TALANTA, 2005, 65 (02) : 559 - 564
  • [37] A glucose biosensor based on TiO2-Graphene composite
    Jang, Hee Dong
    Kim, Sun Kyung
    Chang, Hankwon
    Roh, Ki-Min
    Choi, Jeong-Woo
    Huang, Jiaxing
    BIOSENSORS & BIOELECTRONICS, 2012, 38 (01): : 184 - 188
  • [38] A Non-Enzymatic Glucose Sensor Based on Ni/MnO2 Nanocomposite Modified Glassy Carbon Electrode
    Wang, Yan
    Bai, Wushuang
    Nie, Fei
    Zheng, Jianbin
    ELECTROANALYSIS, 2015, 27 (10) : 2399 - 2405
  • [39] Polyaniline–MnO2 Composite Electrode for Electrochemical Supercapacitor
    V. V. Abalyaeva
    O. N. Efimov
    N. N. Dremova
    E. N. Kabachkov
    Russian Journal of Electrochemistry, 2021, 57 : 996 - 1007
  • [40] Glucose microbiosensor based on MnO2 and glucose oxidase modified carbon fiber microelectrode
    Hocevar, SB
    Ogorevc, B
    Schachl, K
    Kalcher, K
    ELECTROANALYSIS, 2004, 16 (20) : 1711 - 1716