An amperometric glucose biosensor based on a MnO2/graphene composite modified electrode

被引:43
|
作者
Liu, Yuge [1 ]
Zhang, Xiumei [1 ]
He, Dongning [2 ]
Ma, Feiyue [1 ]
Fua, Qiong [1 ]
Hu, Yun [3 ]
机构
[1] Chinese Acad Trop Agr Sci, South Subtrop Crop Res Inst, Key Lab Trop Fruit Biol, Minist Agr, Zhanjiang 524091, Peoples R China
[2] Univ So Queensland, Ctr Excellence Engineered Fibre Composites, Toowoomba, Qld 4350, Australia
[3] China Tobacco Guizhou Ind Co Ltd, Ctr Technol, Guiyang 550002, Peoples R China
基金
中国国家自然科学基金;
关键词
DIRECT ELECTROCHEMISTRY; OXIDASE; GRAPHENE; NANOPARTICLES; IMMOBILIZATION; HEMOGLOBIN; NAFION; FILM; PERFORMANCE;
D O I
10.1039/c6ra02680j
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this paper, a novel composite of graphene/MnO2 (GR/MnO2) was successfully synthesized by a simple one-step hydrothermal method. The as-synthesized MnO2 and the composite were characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS) and Fourier transform infrared spectroscopy (FTIR). The results showed that MnO2 was nanorods and the two materials were perfectly composited. The composite was decorated on a glassy carbon electrode (GCE) and used for the entrapment of glucose oxidase (GOD). Electrochemical results showed that the composite modified electrode showed a pair of well-defined redox peaks, and the direct electron transfer between GOD and the electrode surface was accelerated. The sensor fabricated by the composite modified electrode showed an excellent response to the oxidation of glucose with a wide linear range (0.04 to 2 mM), low detection limit (10 mM), and high sensitivity (3.3 mu A mM(-1) cm(-2)). The sensor also exhibited excellent reproducibility, stability and selectivity, and it can be used in the determination of glucose in real samples.
引用
收藏
页码:18654 / 18661
页数:8
相关论文
共 50 条
  • [21] An amperometric glucose biosensor based on the immobilization of glucose oxidase on the CuGeO3 nanowire modified electrode
    Yong Ping Dong
    Li Huang
    Xiang Feng Chu
    Li Zhai Pei
    Russian Journal of Electrochemistry, 2013, 49 : 571 - 576
  • [22] Amperometric Glucose Biosensor Based on Titanium Electrode Modified with Prussian Blue Layer and Immobilized Glucose Oxidase
    Valiuniene, A.
    Virbickas, P.
    Rekertaite, A.
    Ramanavicius, A.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2017, 164 (14) : B781 - B784
  • [23] An Amperometric Glucose Biosensor Based on the Immobilization of Glucose Oxidase on the CuGeO3 Nanowire Modified Electrode
    Dong, Yong Ping
    Huang, Li
    Chu, Xiang Feng
    Pei, Li Zhai
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2013, 49 (06) : 571 - 576
  • [24] Amperometric Glucose Biosensor Based on AuPd Modified Reduced Graphene Oxide/Polyimide Film with Glucose Oxidase
    Shen, Xuan
    Xia, Xiaohong
    Du, Yongling
    Ye, Weichun
    Wang, Chunming
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2017, 164 (06) : B285 - B291
  • [25] An amperometric biosensor based on laccase immobilized onto MnO2NPs/cMWCNT/PANI modified Au electrode
    Rawal, Rachna
    Chawla, Sheetal
    Malik, Poonam
    Pundir, C. S.
    INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2012, 51 (1-2) : 175 - 181
  • [26] Amperometric sensor for L-ascorbic acid determination based on MnO2 bulk modified screen printed electrode
    Turkusic, E
    Milicevic, V
    Tahmiscija, H
    Vehabovic, M
    Basic, S
    Amidzic, V
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 368 (05): : 466 - 470
  • [27] Amperometric sensor for L-ascorbic acid determination based on MnO2 bulk modified screen printed electrode
    E. Turkusic
    V. Milicevic
    H. Tahmiscija
    M. Vehabovic
    S. Basic
    V. Amidzic
    Fresenius' Journal of Analytical Chemistry, 2000, 368 : 466 - 470
  • [28] Electrochemical properties of graphene/MnO2 composite
    Xu, X. (liudao_zhongsheng@163.com), 1600, Chinese Ceramic Society (41):
  • [29] A method for determination of glucose by an amperometric bienzyme biosensor based on silver nanocubes modified Au electrode
    Yang, Penghao
    Wang, Lisha
    Wu, Qi
    Chen, Zhichun
    Lin, Xianfu
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 194 : 71 - 78
  • [30] Study on the Amperometric Glucose Biosensor Based on Tin Oxide Electrode
    JungChuan Chou
    ShenKan Hsiung
    JuiHsiang Hsieh
    稀有金属材料与工程, 2006, (S3) : 291 - 294