Evaluation of the Abbott ARCHITECT Toxo IgM assay

被引:9
|
作者
Sickinger, Eva [2 ]
Braun, Hans-Bertram [2 ]
Praast, Gerald [2 ]
Stieler, Myriam [2 ]
Gundlach, Cordelia [2 ]
Birkenbach, Claudia [2 ]
Prostko, John [1 ]
Palafox, Mary Ann [1 ]
Frias, Edwin [1 ]
Hsu, Stephen [1 ]
Matias, Matthew [1 ]
Pucci, Dominick [1 ]
Hausmann, Michael [2 ]
Sagel, Ulrich [3 ]
Smith, Darwin [1 ]
机构
[1] Abbott Diagnost, Abbott Pk, IL 60064 USA
[2] Abbott GmbH & Co KG, D-65205 Wiesbaden, Germany
[3] Austrian Agcy Hlth & Food Safety AGES, Inst Med Microbiol & Hyg, A-1096 Vienna, Austria
关键词
Toxoplasmosis; Toxo IgM; Acute infection; TOXOPLASMA-GONDII INFECTION; IMMUNOGLOBULIN-M ANTIBODIES; AGGLUTINATION-TEST; PREGNANT-WOMEN; RISK-FACTORS; AVIDITY; DIAGNOSIS; SYSTEM;
D O I
10.1016/j.diagmicrobio.2009.03.016
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Development of the ARCHITECT Toxo IgM assay has been done to assist the clinician in acute Toxoplasma gondii infection detection, especially in pregnant women. Its use, in conjunction with ARCHITECT Toxo IgG and Toxo Avidity assays, will provide an array of assays particularly useful in the monitoring of pregnant females to determine the risk of maternal transmission of the parasite. Specificity results from 2 testing sites, using populations of pregnant females, hospital patients, and blood donors, demonstrated that the assay has an overall resolved relative specificity of 99.89% (confidence interval, 99.68-99.98%). Relative specificity for pregnant female specimens was 99.95% (n = 2031). Excellent seroconversion sensitivity was observed for the ARCHITECT Toxo IgM assay, which was similar to the Abbott AxSYM Toxo IgM assay (Abbott Laboratories, Abbott Park, IL). In more than 90% of the panels tested, the 1st bleed detected in the serial bleeds was the same for both assays. (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:275 / 282
页数:8
相关论文
共 50 条
  • [41] Evaluation of an assay in development for placental growth factor (P/GF) on the Abbott ARCHITECT® analyzer
    Laird, D. M.
    Bacani, M.
    Eng, K.
    Gardiner, M.
    Pucci, D.
    CLINICAL CHEMISTRY, 2007, 53 (06) : A231 - A231
  • [42] Analytical evaluation of the new Abbott Architect 25-OH vitamin D assay
    Cavalier, Etienne
    Carlisi, Agnes
    Bekaert, Anne-Catherine
    Rousselle, Olivier
    Chapelle, Jean-Paul
    Souberbielle, Jean-Claude
    CLINICAL BIOCHEMISTRY, 2012, 45 (06) : 505 - 508
  • [43] Development and evaluation of an assay for intact parathyroid hormone (PTH) on the Abbott ARCHITECT® immunoassay system
    Martens, M
    Megens, M
    van Wanrooij, M
    van Doorn, D
    Dhein, J
    Eppinger-Albrecht, M
    Hausmann, M
    Jenne, N
    CLINICA CHIMICA ACTA, 2005, 355 : S254 - S255
  • [44] Analytical evaluation of the automated galectin-3 assay on the Abbott ARCHITECT immunoassay instruments
    Gaze, David C.
    Prante, Christian
    Dreier, Jens
    Knabbe, Cornelius
    Collet, Corinne
    Launay, Jean-Marie
    Franekova, Janka
    Jabor, Antonin
    Lennartz, Lieselotte
    Shih, Jessie
    del Rey, Jose Manuel
    Zaninotto, Martina
    Plebani, Mario
    Collinson, Paul O.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2014, 52 (06) : 919 - 926
  • [45] Longitudinal evaluation of the Abbott ARCHITECT SARS-CoV-2 IgM and IgG assays in a pediatric population
    Interiano, Cristina
    Muze, Sheicho
    Turner, Brian
    Gonzalez, Mark
    Rogers, Beverly
    Jerris, Robert
    Weinzierl, Elizabeth
    Elkhalifa, Mohamed
    Van Leung-Pineda
    PRACTICAL LABORATORY MEDICINE, 2021, 25
  • [46] Performance of Abbott ARCHITECT® HAVAB®-M assay for the US
    Brotherton, D.
    Grasso, K.
    Demers, L.
    Heffner, J.
    Himmelsbach, M.
    Adamczyk, J.
    Schwebel, P.
    Rufo, G.
    Bartko, K.
    Mazin, A.
    Xue, M.
    Gawel, S.
    Rios, A.
    Williams, G.
    Mohammad, A. A.
    CLINICAL CHEMISTRY, 2007, 53 (06) : A66 - A66
  • [47] Performance evaluation of the re-standardized Abbott Architect anti-HBs assay
    Wong, Ann H.
    Ho, Yolanda I. I.
    Lai, Raymond W. M.
    JOURNAL OF CLINICAL VIROLOGY, 2019, 111 : 1 - 3
  • [48] T-Uptake assay on the abbott ARCHITECT® iSYSTEM
    Engle, T. L.
    Shull, B. C.
    Bowman, N.
    Verdun, R.
    Arabshahi, L.
    CLINICAL CHEMISTRY, 2006, 52 (06) : A89 - A89
  • [49] Bicentric evaluation of Access Toxo immunoglobulin M (IgM) and IgG assays and IMx Toxo IgM and IgG assays and comparison with platelia Toro IgM and IgG assays
    Decoster, A
    Lecolier, B
    JOURNAL OF CLINICAL MICROBIOLOGY, 1996, 34 (07) : 1606 - 1609
  • [50] Performance of a Toxo IgM prototype assay for the diagnosis of maternal and congenital Toxoplasma infections
    Wallon, Martine
    Fricker-Hidalgo, Helene
    Chapey, Emmanuelle
    Bailet, Claire
    Dard, Celine
    Brenier-Pinchart, Marie-Pierre
    Pelloux, Herve
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2020, 58 (11) : 1959 - 1964