Evaluation of the Abbott ARCHITECT Toxo IgM assay

被引:9
|
作者
Sickinger, Eva [2 ]
Braun, Hans-Bertram [2 ]
Praast, Gerald [2 ]
Stieler, Myriam [2 ]
Gundlach, Cordelia [2 ]
Birkenbach, Claudia [2 ]
Prostko, John [1 ]
Palafox, Mary Ann [1 ]
Frias, Edwin [1 ]
Hsu, Stephen [1 ]
Matias, Matthew [1 ]
Pucci, Dominick [1 ]
Hausmann, Michael [2 ]
Sagel, Ulrich [3 ]
Smith, Darwin [1 ]
机构
[1] Abbott Diagnost, Abbott Pk, IL 60064 USA
[2] Abbott GmbH & Co KG, D-65205 Wiesbaden, Germany
[3] Austrian Agcy Hlth & Food Safety AGES, Inst Med Microbiol & Hyg, A-1096 Vienna, Austria
关键词
Toxoplasmosis; Toxo IgM; Acute infection; TOXOPLASMA-GONDII INFECTION; IMMUNOGLOBULIN-M ANTIBODIES; AGGLUTINATION-TEST; PREGNANT-WOMEN; RISK-FACTORS; AVIDITY; DIAGNOSIS; SYSTEM;
D O I
10.1016/j.diagmicrobio.2009.03.016
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Development of the ARCHITECT Toxo IgM assay has been done to assist the clinician in acute Toxoplasma gondii infection detection, especially in pregnant women. Its use, in conjunction with ARCHITECT Toxo IgG and Toxo Avidity assays, will provide an array of assays particularly useful in the monitoring of pregnant females to determine the risk of maternal transmission of the parasite. Specificity results from 2 testing sites, using populations of pregnant females, hospital patients, and blood donors, demonstrated that the assay has an overall resolved relative specificity of 99.89% (confidence interval, 99.68-99.98%). Relative specificity for pregnant female specimens was 99.95% (n = 2031). Excellent seroconversion sensitivity was observed for the ARCHITECT Toxo IgM assay, which was similar to the Abbott AxSYM Toxo IgM assay (Abbott Laboratories, Abbott Park, IL). In more than 90% of the panels tested, the 1st bleed detected in the serial bleeds was the same for both assays. (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:275 / 282
页数:8
相关论文
共 50 条
  • [31] Analytical performance of the Abbott ARCHITECT® ProGRP assay
    Meany, D. L.
    Dua, R.
    Elliott, D. J.
    Yamada, T.
    Kinukawa, H.
    Chan, S.
    Dowell, B.
    Chan, D. W.
    Sokoll, L. J.
    CLINICAL CHEMISTRY, 2008, 54 (06) : A131 - A131
  • [32] Performance of Abbott ARCHITECT® AUSAB® assay for the US
    Wiesner, D. C.
    Dellamorte, M.
    Kramer, C.
    Rodriguez, T.
    Herrmann, R.
    Rios, A.
    Bartko, K.
    Williams, G.
    CLINICAL CHEMISTRY, 2006, 52 (06) : A49 - A49
  • [33] Performance characteristics of the Abbott ARCHITECT® Progesterone assay
    Rufo, G
    Brookhart, P
    Barnes, W
    Frels, M
    Sheu, M
    White, M
    Chan, S
    Lauren, L
    McHale, P
    Bartko, K
    CLINICAL CHEMISTRY, 2005, 51 : A235 - A235
  • [34] Evaluation of an assay in development for intact parathyroid hormone (PTH) on the Abbott ARCHITECT® analyzer
    Martens, M
    Megens, M
    van Wanrooij, M
    van Doorn, D
    Dhein, J
    Eppinger-Albrecht, M
    Hausmann, M
    Jenne, N
    CLINICAL CHEMISTRY, 2005, 51 : A242 - A242
  • [35] Evaluation of procalcitonin assay on the Abbott Architect i2000 SR® analyzer
    El Mouatani, Ahmed
    Rotaru, Irina
    Beaudeux, Jean-Louis
    Hennequin, Carole
    ANNALES DE BIOLOGIE CLINIQUE, 2018, 76 (03) : 308 - 312
  • [36] Evaluation of the new digoxin assay on the Abbott architect analyser and its correlation with the AxSYM Digoxin II assay
    Outeda-Macias, M.
    Salvador-Garrido, P.
    Espana Valino, L.
    Garcia Queiruga, M.
    Pedreira Vazquez, I
    THERAPEUTIC DRUG MONITORING, 2011, 33 (04) : 502 - 502
  • [37] Next generation direct bilirubin assay for the Abbott AEROSET and Abbott ARCHITECT cSystems
    Muthukumar, A.
    Runnels, L.
    Satomura, S.
    Tanimoto, K.
    Bozimowski, D.
    CLINICAL CHEMISTRY, 2008, 54 (06) : A234 - A234
  • [38] Performance evaluation and clinical experience with the Abbott ARCHITECT STAT Troponin-I assay
    Black, M
    Lam, Q
    Spilsbury, H
    Youdell, O
    Schneider, HG
    CLINICA CHIMICA ACTA, 2005, 355 : S88 - S88
  • [39] Assay performance evaluation of a new immunoassay analyzer, the Abbott ARCHITECT® i1000.
    Patel, R
    Wiviott, M
    Chorazy, J
    Bell, S
    Spear, K
    Badertscher, J
    Lu, M
    Tang, M
    Massie, D
    CLINICAL CHEMISTRY, 2001, 47 (06) : A117 - A117
  • [40] Evaluation of Abbott Architect high-sensitivity troponin I assay for haemolysis interference
    Ryan, J. B.
    Wallace, J.
    Sies, C. W.
    Florkowski, C. M.
    George, P. M.
    PATHOLOGY, 2015, 47 (07) : 716 - 718