Bicentric evaluation of Access Toxo immunoglobulin M (IgM) and IgG assays and IMx Toxo IgM and IgG assays and comparison with platelia Toro IgM and IgG assays

被引:13
|
作者
Decoster, A [1 ]
Lecolier, B [1 ]
机构
[1] HOP NOTRE DAME DE BON SECOURS,F-75674 PARIS 14,FRANCE
关键词
D O I
10.1128/JCM.34.7.1606-1609.1996
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
The recent Access immunoanalysis system (Sanofi Diagnostics Pasteur) for the serological diagnosis of toxoplasmosis was compared with the Abbott Toxo IMx EIA system, taking the Platelia Toxo immunoglobulin G (IgG) and Platelia Toxo IgM systems as references and using as confirmation methods an indirect fluorescence assay or a dye test for IgG and an immunosorbent agglutination assay (ISAGA) for IgM. A total of 1,461 serum samples were studied, of which 128 were collected from 42 recently seroconverted patients. Sensitivity and specificity rates of the Access system were 97.7 and 99.5%, respectively, for IgM and 98.6 and 100%, respectively, for IgG. Sensitivity and specificity rates of the Abbott IMx EIA system were 91 and 100%, respectively, for IgM and 92.5 and 100%, respectively, for IgG. The Access Toxo IgG and IgM EIA systems were found to be more sensitive than the Abbott Toxo IgG and IgM IMx EIA systems.
引用
收藏
页码:1606 / 1609
页数:4
相关论文
共 50 条
  • [1] Toxoplasmosis serodiagnosis:: evaluation of Access® Toxo IgM II assay compared to Axsym® Toxo IgM and Vidas® Toxo IgM assays
    Decoster, A
    Lambert, N
    Germaneau, C
    Masson, C
    [J]. ANNALES DE BIOLOGIE CLINIQUE, 2000, 58 (06) : 721 - 727
  • [2] Laboratory evaluation of the new Access® cytomegalovirus immunoglobulin IgM and IgG assays
    Carlier, Pol
    Harika, Nawal
    Bailly, Ronald
    Vranken, Guido
    [J]. JOURNAL OF CLINICAL VIROLOGY, 2010, 49 (03) : 192 - 197
  • [3] Evaluation of the New Architect Cytomegalovirus Immunoglobulin M (IgM), IgG, and IgG Avidity Assays
    Lagrou, K.
    Bodeus, M.
    Van Ranst, M.
    Goubau, P.
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2009, 47 (06) : 1695 - 1699
  • [4] Performance characteristics of the new ARCHITECT Toxo IgG and Toxo IgG Avidity assays
    Sickinger, Eva
    Gay-Anddrieu, Francoise
    Jonas, Gesa
    Schultess, Jan
    Stieler, Myriam
    Smith, Darwin
    Hausmann, Michael
    Stricker, Rene
    Stricker, Reto
    Dhein, Jens
    Braun, Hans-Bertram
    [J]. DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2008, 62 (03) : 235 - 244
  • [5] Performance of Elecsys® Toxo IgG and IgM Immunoassays
    van Helden, Josef
    [J]. CLINICAL LABORATORY, 2009, 55 (7-8) : 267 - 273
  • [6] Comparative evaluation of the ARCHITECT Toxo IgG, IgM, and IgG Avidity assays for anti-Toxoplasma antibodies detection in pregnant women sera
    Gay-Andrieu, Francoise
    Fricker-Hidalgo, Helene
    Sickinger, Eva
    Espern, Anne
    Brenier-Pinchart, Marie-Pierre
    Braun, Hans-Bertram
    Pelloux, Herve
    [J]. DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2009, 65 (03) : 279 - 287
  • [7] COMPARISON OF THE BECKMAN COULTER ACCESS® CMV IGG AND CMV IGM ASSAYS TO THE ROCHE ELECSYS CMV IGG AND CMV IGM ASSAYS IN ROUTINE LABORATORIES
    Van Helden, J.
    Martin, M.
    Vauloup-Fellous, C.
    Bouniort, F.
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S693 - S693
  • [8] Specificity of low anti-toxoplasma IgG titers with IMx and AxSYM toxo IgG assays
    Cimon, B
    Marty, P
    Morin, O
    Bessières, MH
    Marx-Chemla, C
    Gay-Andrieu, F
    Thulliez, P
    [J]. DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 1998, 32 (01) : 65 - 67
  • [9] Performance evaluation of the VidiaTM toxoplasmosis IgG and IgM assays
    Calderaro, A.
    Piccolo, G.
    Peruzzi, S.
    Dettori, G.
    Chezzi, C.
    [J]. INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 2007, 29 : S489 - S489
  • [10] ELISA ASSAYS FOR IGM AND IGG RHEUMATOID FACTORS
    FAITH, A
    PONTESILLI, O
    UNGER, A
    PANAYI, GS
    JOHNS, P
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 1982, 55 (02) : 169 - 177