Investigation and evaluation of building energy flexibility with energy storage system in hot summer and cold winter zones

被引:22
|
作者
Liu, Jiangyang [1 ]
Yang, Xu [3 ]
Liu, Zhongbing [1 ,2 ]
Zou, Juan [3 ]
Wu, Yaling [1 ]
Zhang, Ling [1 ,2 ]
Zhang, Yelin [1 ,4 ]
Xiao, Hui [5 ]
机构
[1] Hunan Univ, Coll Civil Engn, Changsha 410082, Peoples R China
[2] Hunan Univ, Key Lab Bldg Safety & Energy Efficiency, Minist Educ, Changsha 410082, Peoples R China
[3] Xiangtan Univ, Key Lab Intelligent Comp & Informat Proc, Minist Educ, Informat Engn Coll, Xiangtan, Hunan, Peoples R China
[4] City Univ Hong Kong, Dept Architecture & Civil Engn, Hong Kong, Peoples R China
[5] Changsha Univ Sci & Technol, Dept Elect Engn, Changsha, Peoples R China
关键词
Energy flexibility; Energy storage; Multi-objective optimization; Load coefficient; AIR-CONDITIONING SYSTEM; DEMAND RESPONSE; OPTIMIZATION; PERFORMANCE; MANAGEMENT; DESIGN;
D O I
10.1016/j.est.2021.103877
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The dramatically increasing energy demand of building air-conditioning in hot summer and cold winter zones fluctuates greatly, especially during the period of cooling and heating in summer and winter, which exerts strict operation burden and challenge on power-grid system stability. In order to realize building energy flexibility, this paper proposes a type of energy utilization system including electricity chiller, gas-boiler, electricity heater, cold and thermal energy storage tank (case II), on the basis of electricity chiller and gas-boiler for cooling and heating demand (case I), which is commonly used as cold and heat source in hot summer and cold winter zones. The total cost of the whole life period and annual carbon emission of energy systems are served as objective function is optimized. Furthermore, the system capacity confirmation and load demand management control are analyzed and discussed, the characteristics of energy-flexibility with and without energy storage are presented, the load coefficient is introduced to evaluate the impact of case II on building energy flexibility. Compared with case I, with the deployment of cold and thermal energy storage, the cost-effectiveness of case II is 16.5% and carbon emission is reduced by 30.9% compared with case I .In case II, the load coefficient of electricity chiller and electricity heater is 83.34% and 30.65% respectively, which means that energy storage system enables to promote building energy flexibility improvement and grid-friendliness enhancement. This paper provides methods and theoretical guidance for the planning-operation of building energy system and building energy flexibility in hot summer and cold winter zones.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Performance investigation of a net-zero energy building in hot summer and cold winter zone
    Dong, Zhao
    Zhao, Kang
    Liu, Yueqin
    Ge, Jian
    [J]. JOURNAL OF BUILDING ENGINEERING, 2021, 43
  • [2] Analysis of Building Energy Consumption in a Hospital in the Hot Summer and Cold Winter Area
    Shen, Chenyao
    Zhao, Kang
    Ge, Jian
    Zhou, Qingli
    [J]. INNOVATIVE SOLUTIONS FOR ENERGY TRANSITIONS, 2019, 158 : 3735 - 3740
  • [3] Effect of Building Orientation on Energy Consumption in Hot Summer and Cold Winter Zone
    Li, Tian
    Ni, Jiafei
    Zhang, Ke
    Yao, Jian
    [J]. 2011 INTERNATIONAL CONFERENCE ON MACHINE INTELLIGENCE (ICMI 2011), PT 1, 2011, 3 : 252 - 255
  • [4] Study on Residential Building Energy-saving Comprehensive Evaluation System in Hot Summer and Cold Winter Zone Based on AHP
    Tu, Jinsong
    Li, Ruixia
    Qin, Fengyan
    [J]. SUSTAINABLE ENVIRONMENT AND TRANSPORTATION, PTS 1-4, 2012, 178-181 : 102 - +
  • [5] Analysis of building energy efficiency strategies for the hot summer and cold winter zone in China
    Xie, Dongming
    Zhang, Guoqiang
    Zhou, Jin
    Zhang, Quan
    [J]. BUILDING SIMULATION 2007, VOLS 1-3, PROCEEDINGS, 2007, : 1877 - 1882
  • [6] Thermal design standards for energy efficiency of residential buildings in hot summer/cold winter zones
    Feng, Y
    [J]. ENERGY AND BUILDINGS, 2004, 36 (12) : 1309 - 1312
  • [7] Analysis of the Applicability of a Phase-Change Energy Storage Wall for Public Buildings in Hot Summer and Cold Winter Climate Zones
    Hu, Haowei
    Zhang, Yubin
    Li, Qin
    Shui, Taotao
    He, Jing
    [J]. HEAT TRANSFER ENGINEERING, 2024,
  • [8] Energy-saving Strategy of Building Skins System in Hot-summer and Cold-winter Zone
    Wang, Chongjie
    Zhang, Hong
    Tang, Bing
    Li, Jie
    [J]. PROCEEDINGS OF THE 2018 3RD INTERNATIONAL CONFERENCE ON MODELLING, SIMULATION AND APPLIED MATHEMATICS (MSAM 2018), 2018, 160 : 298 - 300
  • [9] Energy Consumption and Carbon Emissions of Nearly Zero-Energy Buildings in Hot Summer and Cold Winter Zones of China
    Ke, Zikang
    Liu, Xiaoxin
    Zhang, Hui
    Jia, Xueying
    Zeng, Wei
    Yan, Junle
    Hu, Hao
    Hien, Wong Nyuk
    [J]. SUSTAINABILITY, 2023, 15 (14)
  • [10] Adaptability Analysis of Passive Building Energy Efficiency Technology in Hot Summer and Cold Winter Region
    Tong, Qing-gui
    [J]. SUSTAINABLE DEVELOPMENT AND ENVIRONMENT II, PTS 1 AND 2, 2013, 409-410 : 651 - 654