Investigation and evaluation of building energy flexibility with energy storage system in hot summer and cold winter zones

被引:22
|
作者
Liu, Jiangyang [1 ]
Yang, Xu [3 ]
Liu, Zhongbing [1 ,2 ]
Zou, Juan [3 ]
Wu, Yaling [1 ]
Zhang, Ling [1 ,2 ]
Zhang, Yelin [1 ,4 ]
Xiao, Hui [5 ]
机构
[1] Hunan Univ, Coll Civil Engn, Changsha 410082, Peoples R China
[2] Hunan Univ, Key Lab Bldg Safety & Energy Efficiency, Minist Educ, Changsha 410082, Peoples R China
[3] Xiangtan Univ, Key Lab Intelligent Comp & Informat Proc, Minist Educ, Informat Engn Coll, Xiangtan, Hunan, Peoples R China
[4] City Univ Hong Kong, Dept Architecture & Civil Engn, Hong Kong, Peoples R China
[5] Changsha Univ Sci & Technol, Dept Elect Engn, Changsha, Peoples R China
关键词
Energy flexibility; Energy storage; Multi-objective optimization; Load coefficient; AIR-CONDITIONING SYSTEM; DEMAND RESPONSE; OPTIMIZATION; PERFORMANCE; MANAGEMENT; DESIGN;
D O I
10.1016/j.est.2021.103877
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The dramatically increasing energy demand of building air-conditioning in hot summer and cold winter zones fluctuates greatly, especially during the period of cooling and heating in summer and winter, which exerts strict operation burden and challenge on power-grid system stability. In order to realize building energy flexibility, this paper proposes a type of energy utilization system including electricity chiller, gas-boiler, electricity heater, cold and thermal energy storage tank (case II), on the basis of electricity chiller and gas-boiler for cooling and heating demand (case I), which is commonly used as cold and heat source in hot summer and cold winter zones. The total cost of the whole life period and annual carbon emission of energy systems are served as objective function is optimized. Furthermore, the system capacity confirmation and load demand management control are analyzed and discussed, the characteristics of energy-flexibility with and without energy storage are presented, the load coefficient is introduced to evaluate the impact of case II on building energy flexibility. Compared with case I, with the deployment of cold and thermal energy storage, the cost-effectiveness of case II is 16.5% and carbon emission is reduced by 30.9% compared with case I .In case II, the load coefficient of electricity chiller and electricity heater is 83.34% and 30.65% respectively, which means that energy storage system enables to promote building energy flexibility improvement and grid-friendliness enhancement. This paper provides methods and theoretical guidance for the planning-operation of building energy system and building energy flexibility in hot summer and cold winter zones.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Research on Climate Adaptability of Energy Conservation Building with Renewable Energy Sources in Hot-summer and Cold-winter Zone of China
    Hui Zhang
    Zhuang Yu
    RENEWABLE ENERGY AND ENVIRONMENTAL TECHNOLOGY, PTS 1-6, 2014, 448-453 : 1289 - 1296
  • [32] Analysis of small and medium-sized public building energy consumption in hot summer and cold winter area
    He, Changquan
    Journal of Chemical and Pharmaceutical Research, 2014, 6 (04) : 498 - 503
  • [33] Study on Daylighting and Energy Conservation Design of Transparent Envelope for office building in Hot Summer and Cold Winter Zone
    Yu, Jinghua
    Liu, Yu
    Xiong, Chao
    Huang, Jun Chao
    9TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING (ISHVAC) JOINT WITH THE 3RD INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT (COBEE), 2015, 121 : 1642 - 1649
  • [34] ENERGY-EFFICIENT DESIGN OF SUPER HIGH-RISE BUILDING IN HOT SUMMER AND COLD WINTER ZONE
    Qu, Wanying
    SUSTAINABLE CITIES DEVELOPMENT AND ENVIRONMENT PROTECTION, PTS 1-3, 2013, 361-363 : 408 - 413
  • [35] Systematic evaluation of the thermal performance of building envelopes in hot summer and cold winter zone
    College of Civil Engineering, Hunan Univ., Changsha 410082, China
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2008, 35 (10): : 16 - 20
  • [36] Air conditioning energy consumption measurement and saving strategy analysis for an office building in hot summer and cold winter area
    Ran, Bin
    Qiu, Shuting
    Zhang, Ying
    Zeng, Li
    Zhu, Jianming
    Xiang, Zhifeng
    Long, Jibo
    ADVANCES IN BUILDING ENERGY RESEARCH, 2023, 17 (01) : 73 - 97
  • [37] Building energy conservation in atrium spaces based on ECOTECT simulation software in hot summer and cold winter zone in Iran
    Amani, Nima
    INTERNATIONAL JOURNAL OF ENERGY SECTOR MANAGEMENT, 2018, 12 (03) : 298 - 313
  • [38] Building Energy Impacts of Simple Green Roofs in the Hot Summer and Cold Winter Climate Zone: Suzhou as a Study Case
    Tian, Zhen
    Lei, Yaping
    Gu, Xin
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 2918 - 2924
  • [39] Annual energy consumption evaluation of naturally ventilated double skin facade in hot summer and cold winter zone
    Chen, Youming
    Li, Cong
    Wang, Yanjin
    PROCEEDINGS OF BUILDING SIMULATION 2019: 16TH CONFERENCE OF IBPSA, 2020, : 4369 - 4375
  • [40] Research on Flexibility Evaluation of Microgrid System with Energy Storage
    Shi, Tao
    Si, Xuezheng
    Li, Zhaohui
    RECENT ADVANCES IN ELECTRICAL & ELECTRONIC ENGINEERING, 2021, 14 (05) : 525 - 534