Performance investigation of a net-zero energy building in hot summer and cold winter zone

被引:16
|
作者
Dong, Zhao [1 ,2 ]
Zhao, Kang [1 ,3 ]
Liu, Yueqin [4 ]
Ge, Jian [1 ,2 ]
机构
[1] Zhejiang Univ, Dept Architecture, Hangzhou 310058, Peoples R China
[2] Zhejiang Univ, Ctr Balance Architecture, Hangzhou 310007, Peoples R China
[3] Zhejiang Univ Co Ltd, Architectural Design & Res Inst, Hangzhou 310007, Peoples R China
[4] RUNPAQ Technol Co Ltd, Hangzhou 311305, Peoples R China
来源
关键词
Net-zero energy building; Carbon emissions; Life cycle assessment; Operational performance; PV system; LIFE-CYCLE ASSESSMENT; DUST DEPOSITION; CLIMATE; DESIGN; HOUSE; DEGRADATION; METHODOLOGY; EFFICIENCY; QUALITY;
D O I
10.1016/j.jobe.2021.103192
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The net-zero energy building (NZEB) is spreading rapidly as an integrated solution to address energy saving and carbon emissions reduction in the building sector. However, few studies pay close attention to the operational performance of NZEBs as well as their life cycle impact on the environment. This study investigates the operational performance of NZEBs, analyzes the influence factors in achieving net-zero energy, and explores the pathway to reduce the building life cycle carbon emission via a case study conducted from March 2017 to February 2018 in the hot summer and cold winter climate zone of China. The one-year investigation results show that the case building, where energy-efficient technologies and renewable energy were integrated, achieved net-zero energy with good indoor environmental quality. Based on the investigation, influence factors in achieving net-zero energy were analyzed via DesignBuilder: the minimum area per capita was 42 m(2)/person under the circumstance of net-zero energy; when operational strategy was changed, the air-conditioning energy use reduction was less than 5%. Additionally, in order to achieve net-zero energy, an equation was proposed to estimate the area ratio of installed photovoltaic (PV) panels to that of the building roof, thereby providing guidance for NZEBs design. Furthermore, life cycle carbon emissions of the project were evaluated. Based on the foregoing results, it can be concluded that by increasing carbon offsets of the PV system appropriately, an NZEB can be transformed into a life-cycle zero-emission building. Moreover, it is necessary to mention that the life cycle carbon emissions of the PV system should be considered.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Effect of Building Orientation on Energy Consumption in Hot Summer and Cold Winter Zone
    Li, Tian
    Ni, Jiafei
    Zhang, Ke
    Yao, Jian
    2011 INTERNATIONAL CONFERENCE ON MACHINE INTELLIGENCE (ICMI 2011), PT 1, 2011, 3 : 252 - 255
  • [2] Analysis of building energy efficiency strategies for the hot summer and cold winter zone in China
    Xie, Dongming
    Zhang, Guoqiang
    Zhou, Jin
    Zhang, Quan
    BUILDING SIMULATION 2007, VOLS 1-3, PROCEEDINGS, 2007, : 1877 - 1882
  • [3] Systematic evaluation of the thermal performance of building envelopes in hot summer and cold winter zone
    College of Civil Engineering, Hunan Univ., Changsha 410082, China
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2008, 35 (10): : 16 - 20
  • [4] Net-zero energy building schools
    Zeiler, Wim
    Boxem, Gert
    RENEWABLE ENERGY, 2013, 49 : 282 - 286
  • [5] Predicting energy performance of a net-zero energy building: A statistical approach
    Kneifel, Joshua
    Webb, David
    APPLIED ENERGY, 2016, 178 : 468 - 483
  • [6] Green Industrial Building Design For Hot Summer And Cold Winter Zone
    Xiong, Lin
    Mao, Danfei
    ARCHITECTURE, BUILDING MATERIALS AND ENGINEERING MANAGEMENT, PTS 1-4, 2013, 357-360 : 543 - 546
  • [7] Energy performance of net-zero and near net-zero energy homes in New England
    Thomas, Walter D.
    Duffy, John J.
    ENERGY AND BUILDINGS, 2013, 67 : 551 - 558
  • [8] Design of renewable energy systems for near-zero energy residence in hot summer and cold winter zone
    Chen S.-Q.
    Yu A.
    Ming Y.
    Ding D.
    Yang Y.
    Zhejiang Daxue Xuebao (Gongxue Ban)/Journal of Zhejiang University (Engineering Science), 2023, 57 (04): : 795 - 804
  • [9] Indoor Humidity Environment Analysis of Nearly Zero Energy Residence in Hot Summer and Cold Winter Zone
    Su X.
    Tian S.
    Tongji Daxue Xuebao/Journal of Tongji University, 2020, 48 (05): : 725 - 732
  • [10] Investigation and evaluation of building energy flexibility with energy storage system in hot summer and cold winter zones
    Liu, Jiangyang
    Yang, Xu
    Liu, Zhongbing
    Zou, Juan
    Wu, Yaling
    Zhang, Ling
    Zhang, Yelin
    Xiao, Hui
    JOURNAL OF ENERGY STORAGE, 2022, 46