Performance investigation of a net-zero energy building in hot summer and cold winter zone

被引:16
|
作者
Dong, Zhao [1 ,2 ]
Zhao, Kang [1 ,3 ]
Liu, Yueqin [4 ]
Ge, Jian [1 ,2 ]
机构
[1] Zhejiang Univ, Dept Architecture, Hangzhou 310058, Peoples R China
[2] Zhejiang Univ, Ctr Balance Architecture, Hangzhou 310007, Peoples R China
[3] Zhejiang Univ Co Ltd, Architectural Design & Res Inst, Hangzhou 310007, Peoples R China
[4] RUNPAQ Technol Co Ltd, Hangzhou 311305, Peoples R China
来源
关键词
Net-zero energy building; Carbon emissions; Life cycle assessment; Operational performance; PV system; LIFE-CYCLE ASSESSMENT; DUST DEPOSITION; CLIMATE; DESIGN; HOUSE; DEGRADATION; METHODOLOGY; EFFICIENCY; QUALITY;
D O I
10.1016/j.jobe.2021.103192
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The net-zero energy building (NZEB) is spreading rapidly as an integrated solution to address energy saving and carbon emissions reduction in the building sector. However, few studies pay close attention to the operational performance of NZEBs as well as their life cycle impact on the environment. This study investigates the operational performance of NZEBs, analyzes the influence factors in achieving net-zero energy, and explores the pathway to reduce the building life cycle carbon emission via a case study conducted from March 2017 to February 2018 in the hot summer and cold winter climate zone of China. The one-year investigation results show that the case building, where energy-efficient technologies and renewable energy were integrated, achieved net-zero energy with good indoor environmental quality. Based on the investigation, influence factors in achieving net-zero energy were analyzed via DesignBuilder: the minimum area per capita was 42 m(2)/person under the circumstance of net-zero energy; when operational strategy was changed, the air-conditioning energy use reduction was less than 5%. Additionally, in order to achieve net-zero energy, an equation was proposed to estimate the area ratio of installed photovoltaic (PV) panels to that of the building roof, thereby providing guidance for NZEBs design. Furthermore, life cycle carbon emissions of the project were evaluated. Based on the foregoing results, it can be concluded that by increasing carbon offsets of the PV system appropriately, an NZEB can be transformed into a life-cycle zero-emission building. Moreover, it is necessary to mention that the life cycle carbon emissions of the PV system should be considered.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Performance simulation of underground seasonal solar energy storage in hot summer and cold winter zone in china
    Li, Yong
    Chen, Xudong
    Ipposhi, Shigetoshi
    Nomura, Yasumitsu
    Wang, Ruzhu
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2019, 25 (07) : 925 - 934
  • [32] Energy and Economic Performance of Solar Cooling Systems in the Hot-Summer and Cold-Winter Zone
    Huang, Li
    Zheng, Rongyue
    BUILDINGS, 2018, 8 (03)
  • [33] Research on Energy-Saving Performance of Intermittent Heating for Rooms in Hot Summer & Cold Winter Zone
    Yu G.
    Fang N.
    Hu D.
    Zhao W.
    Energy Engineering: Journal of the Association of Energy Engineering, 2023, 120 (07): : 1563 - 1582
  • [34] Thermal performance evaluation model for VDSF in hot summer and cold winter zone
    Bi, Yuan
    Chen, Youming
    Zhou, Juan
    Lu, Xiang
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2015, 36 (07): : 1724 - 1730
  • [35] Analysis of Building Energy Consumption in a Hospital in the Hot Summer and Cold Winter Area
    Shen, Chenyao
    Zhao, Kang
    Ge, Jian
    Zhou, Qingli
    INNOVATIVE SOLUTIONS FOR ENERGY TRANSITIONS, 2019, 158 : 3735 - 3740
  • [36] Building energy saving potential in Hot Summer and Cold Winter (HSCW) Zone, China-Influence of building energy efficiency standards and implications
    Xu, Luyi
    Liu, Junjie
    Pei, Jingjing
    Han, Xu
    ENERGY POLICY, 2013, 57 : 253 - 262
  • [37] Investigation on building external insulation facade system energy saving techniques in 'hot summer/warm winter' zone
    Li, Zhi-Sheng
    Lu, Shao-Hui
    Zhang, Guo-Qiang
    Li, Li-Xin
    Mei, Sheng
    Li, Dong-Mei
    Journal of Harbin Institute of Technology (New Series), 2007, 14 (SUPPL.) : 51 - 53
  • [38] Multi-objective optimization of energy, visual, and thermal performance for building envelopes in China?s hot summer and cold winter climate zone
    Wu, Haoran
    Zhang, Tong
    JOURNAL OF BUILDING ENGINEERING, 2022, 59
  • [39] Evaluation of the energy performance of a net zero energy building in a hot and humid climate
    Shin, Minjae
    Baltazar, Juan-Carlos
    Haberl, Jeff S.
    Frazier, Edwin
    Lynn, Bobby
    ENERGY AND BUILDINGS, 2019, 204
  • [40] Building Energy Impacts of Simple Green Roofs in the Hot Summer and Cold Winter Climate Zone: Suzhou as a Study Case
    Tian, Zhen
    Lei, Yaping
    Gu, Xin
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 2918 - 2924