LROC assessment of non-linear filtering methods in Ga-67SPECT imaging.

被引:0
|
作者
De Clercq, Stijn [1 ]
Staelens, Steven [1 ]
De Beenhouwer, Jan [1 ]
D'Asseler, Yves [1 ]
Lemahieu, Ignace [1 ]
机构
[1] Univ Ghent, ELIS MEDISIP, Sint Pietersnieustr 41, B-9000 Ghent, Belgium
关键词
LROC; edge-preserving filtering; gallium SPECT; bootstrap;
D O I
10.1117/12.655897
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In emission tomography, iterative reconstruction is usually followed by a linear smoothing filter to make such images more appropriate for visual inspection and diagnosis by a physician. This will result in a global blurring of the images, smoothing across edges and possibly discarding valuable image information for detection tasks. The purpose of this study is to investigate which possible advantages a non-linear, edge-preserving postfilter could have on lesion detection in Ga-67 SPECT imaging. Image quality can be defined based on the task that has to be performed on the image. This study used LROC observer studies based on a dataset created by CPU-intensive Gate Monte Carlo simulations of a voxelized digital phantom. The filters considered in this study were a linear Gaussian filter, a bilateral filter, the Perona-Malik anisotropic diffusion filter and the Catte filtering scheme. The 3D MCAT software phantom was used to simulate the distribution of Ga-67 citrate in the abdomen. Tumor-present cases had a 1-cm diameter tumor randomly placed near the edges of the anatomical boundaries of the kidneys, bone, liver and spleen. Our data set was generated out of a single noisy background simulation using the bootstrap method, to significantly reduce the simulation time and to allow for a larger observer data set. Lesions were simulated separately and added to the background afterwards. These were then reconstructed with an iterative approach, using a sufficiently large number of MLEM iterations to establish convergence. The output of a numerical observer was used in a simplex optimization method to estimate an optimal set of parameters for each postfilter. No significant improvement was found for using edge-preserving filtering techniques over standard linear Gaussian filtering.
引用
收藏
页数:14
相关论文
共 43 条
  • [31] A 3-D non-linear registration algorithm for functional SPECT brain imaging using optical flow.
    Janicki, C
    Meunier, J
    Soucy, JP
    Imbert, B
    Guimond, A
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 508 - 508
  • [32] COMPUTER STUDIES OF LINEAR AND NON-LINEAR PROCESSING FOR REFLECTION TOMOGRAPHIC DATA - EXTENSION OF SYNTHETIC FOCUS IMAGING METHODS FOR MEDICINE
    JOHNSON, SA
    GREENLEAF, JF
    RAJAGOPALAN, B
    TANAKA, M
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1978, 64 : S177 - S177
  • [33] BIDIRECTIONAL ULTRASOUND ELASTOGRAPHIC IMAGING FRAMEWORK FOR NON-INVASIVE ASSESSMENT OF THE NON-LINEAR BEHAVIOR OF A PHYSIOLOGICALLY PRESSURIZED ARTERY
    Wang, Yahua
    Li, He
    Guo, Yuexin
    Lee, Wei-Ning
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (05): : 1184 - 1196
  • [34] Non-linear dynamic techniques v. equivalent conicity methods for rail vehicle stability assessment
    Goodall, RM
    Iwnicki, SD
    [J]. DYNAMICS OF VEHICLES ON ROADS AND ON TRACKS, 2003, : 791 - 799
  • [35] Online NIRS analysis for the routine assessment of the nitrate content in spinach plants in the processing industry using linear and non-linear methods
    Vega-Castellote, Miguel
    Perez-Marin, Dolores
    Torres, Irina
    Sanchez, Maria-Teresa
    [J]. LWT-FOOD SCIENCE AND TECHNOLOGY, 2021, 151
  • [36] An Assessment of Deep Learning Versus Massively Parallel, Non-Linear Methods for Highly-Efficient MIMO Detection
    Ducoing, J. C. De Luna
    Jayawardena, Chathura
    Nikitopoulos, Konstantinos
    [J]. IEEE ACCESS, 2023, 11 : 97493 - 97502
  • [37] CORRECTION OF NON-LINEAR PROPAGATION ARTIFACT IN CONTRAST-ENHANCED ULTRASOUND IMAGING OF CAROTID ARTERIES: METHODS AND IN VITRO EVALUATION
    Yildiz, Yesna O.
    Eckersley, Robert J.
    Senior, Roxy
    Lim, Adrian K. P.
    Cosgrove, David
    Tang, Meng-Xing
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (07): : 1938 - 1947
  • [38] Assessment of murine colorectal cancer by micro-ultrasound using three dimensional reconstruction and non-linear contrast imaging
    Freeling, Jessica L.
    Rezvani, Khosrow
    [J]. MOLECULAR THERAPY-METHODS & CLINICAL DEVELOPMENT, 2016, 3 : 16070
  • [39] Determination of Sugar, pH, and Anthocyanin Contents in Port Wine Grape Berries through Hyperspectral Imaging: An Extensive Comparison of Linear and Non-Linear Predictive Methods
    Gomes, Veronique
    Rendall, Ricardo
    Reis, Marco Seabra
    Mendes-Ferreira, Ana
    Melo-Pinto, Pedro
    [J]. APPLIED SCIENCES-BASEL, 2021, 11 (21):
  • [40] Beyond endoscopic assessment in inflammatory bowel disease: real-time histology of disease activity by non-linear multimodal imaging
    Chernavskaia, Olga
    Heuke, Sandro
    Vieth, Michael
    Friedrich, Oliver
    Schuermann, Sebastian
    Atreya, Raja
    Stallmach, Andreas
    Neurath, Markus F.
    Waldner, Maximilian
    Petersen, Iver
    Schmitt, Michael
    Bocklitz, Thomas
    Popp, Juergen
    [J]. SCIENTIFIC REPORTS, 2016, 6