LROC assessment of non-linear filtering methods in Ga-67SPECT imaging.

被引:0
|
作者
De Clercq, Stijn [1 ]
Staelens, Steven [1 ]
De Beenhouwer, Jan [1 ]
D'Asseler, Yves [1 ]
Lemahieu, Ignace [1 ]
机构
[1] Univ Ghent, ELIS MEDISIP, Sint Pietersnieustr 41, B-9000 Ghent, Belgium
关键词
LROC; edge-preserving filtering; gallium SPECT; bootstrap;
D O I
10.1117/12.655897
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In emission tomography, iterative reconstruction is usually followed by a linear smoothing filter to make such images more appropriate for visual inspection and diagnosis by a physician. This will result in a global blurring of the images, smoothing across edges and possibly discarding valuable image information for detection tasks. The purpose of this study is to investigate which possible advantages a non-linear, edge-preserving postfilter could have on lesion detection in Ga-67 SPECT imaging. Image quality can be defined based on the task that has to be performed on the image. This study used LROC observer studies based on a dataset created by CPU-intensive Gate Monte Carlo simulations of a voxelized digital phantom. The filters considered in this study were a linear Gaussian filter, a bilateral filter, the Perona-Malik anisotropic diffusion filter and the Catte filtering scheme. The 3D MCAT software phantom was used to simulate the distribution of Ga-67 citrate in the abdomen. Tumor-present cases had a 1-cm diameter tumor randomly placed near the edges of the anatomical boundaries of the kidneys, bone, liver and spleen. Our data set was generated out of a single noisy background simulation using the bootstrap method, to significantly reduce the simulation time and to allow for a larger observer data set. Lesions were simulated separately and added to the background afterwards. These were then reconstructed with an iterative approach, using a sufficiently large number of MLEM iterations to establish convergence. The output of a numerical observer was used in a simplex optimization method to estimate an optimal set of parameters for each postfilter. No significant improvement was found for using edge-preserving filtering techniques over standard linear Gaussian filtering.
引用
收藏
页数:14
相关论文
共 43 条
  • [21] Adjoint field methods for non-linear tomographic medical imaging problems
    Boverman, G
    Miller, E
    [J]. 2002 INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOL II, PROCEEDINGS, 2002, : 633 - 636
  • [22] On non-linear methods of bogie stability assessment using computer simulations
    Polach, O
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART F-JOURNAL OF RAIL AND RAPID TRANSIT, 2006, 220 (01) : 13 - 27
  • [23] Non-linear Methods for the Assessment of Seismic Vulnerability of Masonry Historical Buildings
    Croce, Pietro
    Landi, Filippo
    Formichi, Paolo
    Beconcini, Maria Luisa
    Puccini, Benedetta
    Zotti, Vincenzo
    [J]. PROTECTION OF HISTORICAL CONSTRUCTIONS, PROHITECH 2021, 2022, 209 : 651 - 670
  • [24] Analyzing specific and nonspecific tissue uptake of antibodies by SPECT imaging and non-linear compartmental modeling
    Cho, Nicholas
    Spinosa, Phillip
    Mandikian, Danielle
    Del Rosario, Geoffrey
    Yu, Shang-Fan
    Ho, Jason
    Ferl, Greg
    Boswell, Charles A.
    [J]. CANCER RESEARCH, 2024, 84 (06)
  • [25] APPLICATION PECULIARITIES OF NON-LINEAR SCAN FILTERING METHODS IN CSP AND DSS DATA-PROCESSING
    CHEKHUTSKY, GA
    [J]. OKEANOLOGIYA, 1983, 23 (04): : 688 - 693
  • [26] The efficacy of 2D, non-linear noise reduction filtering in cardiac imaging: a pilot study
    De Geer, Jakob
    Sandborg, Michael
    Smedby, Orjan
    Persson, Anders
    [J]. ACTA RADIOLOGICA, 2011, 52 (07) : 716 - 722
  • [27] Wheat Flour Quality Assessment by Fundamental Non-Linear Rheological Methods: A Critical Review
    Yazar, Gamze
    [J]. FOODS, 2023, 12 (18)
  • [28] Biomechanical Assessment Methods Used in Chronic Stroke: A Scoping Review of Non-Linear Approaches
    Freitas, Marta
    Pinho, Francisco
    Pinho, Liliana
    Silva, Sandra
    Figueira, Vania
    Vilas-Boas, Joao Paulo
    Silva, Augusta
    [J]. SENSORS, 2024, 24 (07)
  • [29] A 3-D non-linear registration algorithm for brain SPECT imaging within the Talairach reference system
    Meunier, J
    Imbert, B
    Janicki, C
    Guimond, A
    Soucy, JP
    [J]. IMAGE PROCESSING - MEDICAL IMAGING 1997, PTS 1 AND 2, 1997, 3034 : 919 - 930
  • [30] Ground Photometric Measurements Inversion Methods for Space Object Characteristics Based on Non-linear Filtering: A Short Review
    Wang Y.
    Du X.
    Xu C.
    Ma Z.
    Yin Z.
    [J]. Recent Advances in Computer Science and Communications, 2022, 15 (09) : 1184 - 1193