Assessment of a Virtual Functional Prototyping Process for the Rapid Manufacture of Passive-Dynamic Ankle-Foot Orthoses

被引:53
|
作者
Schrank, Elisa S. [1 ]
Hitch, Lester [2 ]
Wallace, Kevin [2 ]
Moore, Richard [2 ]
Stanhope, Steven J. [3 ]
机构
[1] Univ Delaware, Dept Kinesiol & Appl Physiol, Newark, DE 19711 USA
[2] US Army Edgewood Chem Biol Ctr, Adv Design & Mfg Div, Edgewood, MD 21010 USA
[3] Univ Delaware, Dept Kinesiol & Appl Physiol, Biomech & Movement Sci Interdisciplinary Program, Dept Mech Engn,Dept Biomed Engn, Newark, DE 19711 USA
基金
美国国家科学基金会;
关键词
ankle; computer-aided design; customization; finite element analysis; fused deposition modeling; orthosis; orthotics; rehabilitation; bending stiffness; virtual functional prototyping; PROSTHETIC SOCKET; MECHANICAL PROPERTY; STIFFNESS; ORTHOTICS; CUSTOMIZATION; POLYPROPYLENE; FABRICATION; TECHNOLOGY; ACCURACY; DESIGN;
D O I
10.1115/1.4024825
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Passive-dynamic ankle-foot orthosis (PD-AFO) bending stiffness is a key functional characteristic for achieving enhanced gait function. However, current orthosis customization methods inhibit objective premanufacture tuning of the PD-AFO bending stiffness, making optimization of orthosis function challenging. We have developed a novel virtual functional prototyping (VFP) process, which harnesses the strengths of computer aided design (CAD) model parameterization and finite element analysis, to quantitatively tune and predict the functional characteristics of a PD-AFO, which is rapidly manufactured via fused deposition modeling (FDM). The purpose of this study was to assess the VFP process for PD-AFO bending stiffness. A PD-AFO CAD model was customized for a healthy subject and tuned to four bending stiffness values via VFP. Two sets of each tuned model were fabricated via FDM using medical-grade polycarbonate (PC-ISO). Dimensional accuracy of the fabricated orthoses was excellent (average 0.51 +/- 0.39 mm). Manufacturing precision ranged from 0.0 to 0.74 Nm/deg (average 0.30 +/- 0.36 Nm/deg). Bending stiffness prediction accuracy was within 1 Nm/deg using the manufacturer provided PC-ISO elastic modulus (average 0.48 +/- 0.35 Nm/deg). Using an experimentally derived PC-ISO elastic modulus improved the optimized bending stiffness prediction accuracy (average 0.29 +/- 0.57 Nm/deg). Robustness of the derived modulus was tested by carrying out the VFP process for a disparate subject, tuning the PD-AFO model to five bending stiffness values. For this disparate subject, bending stiffness prediction accuracy was strong (average 0.20 +/- 0.14 Nm/deg). Overall, the VFP process had excellent dimensional accuracy, good manufacturing precision, and strong prediction accuracy with the derived modulus. Implementing VFP as part of our PD-AFO customization and manufacturing framework, which also includes fit customization, provides a novel and powerful method to predictably tune and precisely manufacture orthoses with objectively customized fit and functional characteristics.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Assessment of Appropriate Ankle-Foot Orthoses Models for Patients with Charcot-Marie-Tooth Disease
    Guillebastre, Bastien
    Calmels, Paul
    Rougier, Patrice R.
    [J]. AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2011, 90 (08) : 619 - 627
  • [42] The effects of dynamic ankle-foot orthoses on functional ambulation activities, weight bearing and spatio-temporal characteristics of hemiparetic gait
    Suat, Erel
    Fatma, Uygur
    Nilgun, Bek
    [J]. DISABILITY AND REHABILITATION, 2011, 33 (25-26) : 2605 - 2611
  • [43] CORR Insights®: Military Service Members with Major Lower Extremity Fractures Return to Running with a Passive-dynamic Ankle-foot Orthosis: Comparison with a Normative Population
    Potter, Benjamin K.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2021, 479 (11) : 2385 - 2387
  • [44] A Clinical Practice Guideline for the Use of Ankle-Foot Orthoses and Functional Electrical Stimulation Post-Stroke
    Johnston, Therese E.
    Keller, Sarah
    Denzer-Weiler, Caitlin
    Brown, Lisa
    [J]. JOURNAL OF NEUROLOGIC PHYSICAL THERAPY, 2021, 45 (02): : 112 - 196
  • [45] Letter to the Editor: Military Service Members With Major Lower Extremity Fractures Return to Running With a Passive-dynamic Ankle-foot Orthosis: Comparison With a Normative Population
    Ekinci, Safak
    Ozyigit, Elif
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2022, 480 (08) : 1618 - 1618
  • [46] Human-Robot Joint Misalignment, Physical Interaction, and Gait Kinematic Assessment in Ankle-Foot Orthoses
    Andrade, Ricardo Luis
    Figueiredo, Joana
    Fonseca, Pedro
    Vilas-Boas, Joao P.
    Silva, Miguel T.
    Santos, Cristina P.
    [J]. SENSORS, 2024, 24 (01)
  • [47] Analyzing Effects of Ankle-Foot Parameters on Passive Bipeds Based on Dynamic Walking Modeling
    Mai, Jingeng
    Gao, Yue
    Huang, Yan
    Wang, Qining
    Zhang, Lin
    [J]. ASIASIM 2012, PT I, 2012, 323 : 135 - +
  • [48] Effect of ankle-foot orthoses on functional outcome measurements in individuals with stroke: a systematic review and meta-analysis
    Daryabor, Aliyeh
    Kobayashi, Toshiki
    Yamamoto, Sumiko
    Lyons, Samuel M.
    Orendurff, Michael
    Baghban, Alireza Akbarzadeh
    [J]. DISABILITY AND REHABILITATION, 2022, 44 (22) : 6566 - 6581
  • [49] A Survey of Clinical Practice Patterns of Physical Therapists for the Use of Ankle-Foot Orthoses or Functional Electrical Stimulation Poststroke
    Brown, Lisa
    Johnston, Therese E.
    Keller, Sarah
    Denzer-Weiler, Caitlin
    [J]. JOURNAL OF PROSTHETICS AND ORTHOTICS, 2024, 36 (02) : 124 - 132
  • [50] Six-Minute Walk Test Performance in Persons With Multiple Sclerosis While Using Passive or Powered Ankle-Foot Orthoses
    Boes, Morgan K.
    Bollaert, Rachel E.
    Kesler, Richard M.
    Learmonth, Yvonne C.
    Islam, Mazharul
    Petrucci, Matthew N.
    Motl, Robert W.
    Hsiao-Wecksler, Elizabeth T.
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2018, 99 (03): : 484 - 490