Assessment of a Virtual Functional Prototyping Process for the Rapid Manufacture of Passive-Dynamic Ankle-Foot Orthoses

被引:53
|
作者
Schrank, Elisa S. [1 ]
Hitch, Lester [2 ]
Wallace, Kevin [2 ]
Moore, Richard [2 ]
Stanhope, Steven J. [3 ]
机构
[1] Univ Delaware, Dept Kinesiol & Appl Physiol, Newark, DE 19711 USA
[2] US Army Edgewood Chem Biol Ctr, Adv Design & Mfg Div, Edgewood, MD 21010 USA
[3] Univ Delaware, Dept Kinesiol & Appl Physiol, Biomech & Movement Sci Interdisciplinary Program, Dept Mech Engn,Dept Biomed Engn, Newark, DE 19711 USA
基金
美国国家科学基金会;
关键词
ankle; computer-aided design; customization; finite element analysis; fused deposition modeling; orthosis; orthotics; rehabilitation; bending stiffness; virtual functional prototyping; PROSTHETIC SOCKET; MECHANICAL PROPERTY; STIFFNESS; ORTHOTICS; CUSTOMIZATION; POLYPROPYLENE; FABRICATION; TECHNOLOGY; ACCURACY; DESIGN;
D O I
10.1115/1.4024825
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Passive-dynamic ankle-foot orthosis (PD-AFO) bending stiffness is a key functional characteristic for achieving enhanced gait function. However, current orthosis customization methods inhibit objective premanufacture tuning of the PD-AFO bending stiffness, making optimization of orthosis function challenging. We have developed a novel virtual functional prototyping (VFP) process, which harnesses the strengths of computer aided design (CAD) model parameterization and finite element analysis, to quantitatively tune and predict the functional characteristics of a PD-AFO, which is rapidly manufactured via fused deposition modeling (FDM). The purpose of this study was to assess the VFP process for PD-AFO bending stiffness. A PD-AFO CAD model was customized for a healthy subject and tuned to four bending stiffness values via VFP. Two sets of each tuned model were fabricated via FDM using medical-grade polycarbonate (PC-ISO). Dimensional accuracy of the fabricated orthoses was excellent (average 0.51 +/- 0.39 mm). Manufacturing precision ranged from 0.0 to 0.74 Nm/deg (average 0.30 +/- 0.36 Nm/deg). Bending stiffness prediction accuracy was within 1 Nm/deg using the manufacturer provided PC-ISO elastic modulus (average 0.48 +/- 0.35 Nm/deg). Using an experimentally derived PC-ISO elastic modulus improved the optimized bending stiffness prediction accuracy (average 0.29 +/- 0.57 Nm/deg). Robustness of the derived modulus was tested by carrying out the VFP process for a disparate subject, tuning the PD-AFO model to five bending stiffness values. For this disparate subject, bending stiffness prediction accuracy was strong (average 0.20 +/- 0.14 Nm/deg). Overall, the VFP process had excellent dimensional accuracy, good manufacturing precision, and strong prediction accuracy with the derived modulus. Implementing VFP as part of our PD-AFO customization and manufacturing framework, which also includes fit customization, provides a novel and powerful method to predictably tune and precisely manufacture orthoses with objectively customized fit and functional characteristics.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] The influence of passive-dynamic ankle-foot orthosis bending axis location on gait performance in individuals with lower-limb impairments
    Ranz, Ellyn C.
    Esposito, Elizabeth Russell
    Wilken, Jason M.
    Neptune, Richard R.
    [J]. CLINICAL BIOMECHANICS, 2016, 37 : 13 - 21
  • [32] Military Service Members with Major Lower Extremity Fractures Return to Running with a Passive-dynamic Ankle-foot Orthosis: Comparison with a Normative Population
    Peterson, Shian Liu
    Kingsbury, Trevor D.
    Djafar, Tatiana
    Stewart, Julianne
    Kuhn, Kevin M.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2021, 479 (11) : 2375 - 2384
  • [33] Passive Articulated and Non-Articulated Ankle-Foot Orthoses for Gait Rehabilitation: A Narrative Review
    Nazha, Hasan Mhd
    Szavai, Szabolcs
    Darwich, Mhd Ayham
    Juhre, Daniel
    [J]. HEALTHCARE, 2023, 11 (07)
  • [34] Effects of Ankle-Foot Orthoses for Children with Hemiplegia on Weight-Bearing and Functional Ability
    O'Reilly, Tara
    Hunt, Adrienne
    Thomas, Bronwyn
    Harris, Lynne
    Burns, Joshua
    [J]. PEDIATRIC PHYSICAL THERAPY, 2009, 21 (03) : 225 - 234
  • [35] A comparison of gait with solid, dynamic, and no ankle-foot orthoses in children with spastic cerebral palsy
    Radtka, SA
    Skinner, SR
    Dixon, DM
    Johanson, ME
    [J]. PHYSICAL THERAPY, 1997, 77 (04): : 395 - 409
  • [36] Evaluation of various design concepts in passive ankle-foot orthoses using finite element analysis
    Surmen, Hasan Kemal
    Arslan, Yunus Ziya
    [J]. ENGINEERING SCIENCE AND TECHNOLOGY-AN INTERNATIONAL JOURNAL-JESTECH, 2021, 24 (06): : 1301 - 1307
  • [37] Effects of dynamic ankle-foot orthoses on standing in children with severe spastic diplegia COMMENTARY
    Sussman, Michael
    [J]. INTERNATIONAL JOURNAL OF THERAPY AND REHABILITATION, 2005, 12 (05): : 207 - 207
  • [38] EFFECTS OF ANKLE-FOOT ORTHOSES ON FUNCTIONAL MOTOR-PERFORMANCE IN A CHILD WITH SPASTIC DIPLEGIA
    TAYLOR, CL
    HARRIS, SR
    [J]. AMERICAN JOURNAL OF OCCUPATIONAL THERAPY, 1986, 40 (07): : 492 - 494
  • [39] Design principles, manufacturing and evaluation techniques of custom dynamic ankle-foot orthoses: a review study
    Rogati, Giulia
    Caravaggi, Paolo
    Leardini, Alberto
    [J]. JOURNAL OF FOOT AND ANKLE RESEARCH, 2022, 15 (01)
  • [40] Design principles, manufacturing and evaluation techniques of custom dynamic ankle-foot orthoses: a review study
    Giulia Rogati
    Paolo Caravaggi
    Alberto Leardini
    [J]. Journal of Foot and Ankle Research, 15