Assessment of a Virtual Functional Prototyping Process for the Rapid Manufacture of Passive-Dynamic Ankle-Foot Orthoses

被引:53
|
作者
Schrank, Elisa S. [1 ]
Hitch, Lester [2 ]
Wallace, Kevin [2 ]
Moore, Richard [2 ]
Stanhope, Steven J. [3 ]
机构
[1] Univ Delaware, Dept Kinesiol & Appl Physiol, Newark, DE 19711 USA
[2] US Army Edgewood Chem Biol Ctr, Adv Design & Mfg Div, Edgewood, MD 21010 USA
[3] Univ Delaware, Dept Kinesiol & Appl Physiol, Biomech & Movement Sci Interdisciplinary Program, Dept Mech Engn,Dept Biomed Engn, Newark, DE 19711 USA
基金
美国国家科学基金会;
关键词
ankle; computer-aided design; customization; finite element analysis; fused deposition modeling; orthosis; orthotics; rehabilitation; bending stiffness; virtual functional prototyping; PROSTHETIC SOCKET; MECHANICAL PROPERTY; STIFFNESS; ORTHOTICS; CUSTOMIZATION; POLYPROPYLENE; FABRICATION; TECHNOLOGY; ACCURACY; DESIGN;
D O I
10.1115/1.4024825
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Passive-dynamic ankle-foot orthosis (PD-AFO) bending stiffness is a key functional characteristic for achieving enhanced gait function. However, current orthosis customization methods inhibit objective premanufacture tuning of the PD-AFO bending stiffness, making optimization of orthosis function challenging. We have developed a novel virtual functional prototyping (VFP) process, which harnesses the strengths of computer aided design (CAD) model parameterization and finite element analysis, to quantitatively tune and predict the functional characteristics of a PD-AFO, which is rapidly manufactured via fused deposition modeling (FDM). The purpose of this study was to assess the VFP process for PD-AFO bending stiffness. A PD-AFO CAD model was customized for a healthy subject and tuned to four bending stiffness values via VFP. Two sets of each tuned model were fabricated via FDM using medical-grade polycarbonate (PC-ISO). Dimensional accuracy of the fabricated orthoses was excellent (average 0.51 +/- 0.39 mm). Manufacturing precision ranged from 0.0 to 0.74 Nm/deg (average 0.30 +/- 0.36 Nm/deg). Bending stiffness prediction accuracy was within 1 Nm/deg using the manufacturer provided PC-ISO elastic modulus (average 0.48 +/- 0.35 Nm/deg). Using an experimentally derived PC-ISO elastic modulus improved the optimized bending stiffness prediction accuracy (average 0.29 +/- 0.57 Nm/deg). Robustness of the derived modulus was tested by carrying out the VFP process for a disparate subject, tuning the PD-AFO model to five bending stiffness values. For this disparate subject, bending stiffness prediction accuracy was strong (average 0.20 +/- 0.14 Nm/deg). Overall, the VFP process had excellent dimensional accuracy, good manufacturing precision, and strong prediction accuracy with the derived modulus. Implementing VFP as part of our PD-AFO customization and manufacturing framework, which also includes fit customization, provides a novel and powerful method to predictably tune and precisely manufacture orthoses with objectively customized fit and functional characteristics.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] A Novel Dorsal Trimline Approach for Passive-Dynamic Ankle-Foot Orthoses
    Surmen, Hasan Kemal
    Akalan, Nazif Ekin
    Fetvaci, Mahmut Cuneyt
    Arslan, Yunus Ziya
    [J]. STROJNISKI VESTNIK-JOURNAL OF MECHANICAL ENGINEERING, 2018, 64 (03): : 185 - 194
  • [2] Passive-Dynamic Ankle-Foot Orthoses Affect Walking Stability on Sloped Terrain
    Esposito, Elizabeth Russell
    Rabago, Christopher A.
    Wilken, Jason M.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2016, 48 (05): : 721 - 721
  • [3] Manufacture of passive dynamic ankle-foot orthoses using selective laser sintering
    Faustini, Mario C.
    Neptune, Richard R.
    Crawford, Richard H.
    Stanhope, Steven J.
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (02) : 784 - 790
  • [4] Patient specific ankle-foot orthoses using rapid prototyping
    Mavroidis, Constantinos
    Ranky, Richard G.
    Sivak, Mark L.
    Patritti, Benjamin L.
    DiPisa, Joseph
    Caddle, Alyssa
    Gilhooly, Kara
    Govoni, Lauren
    Sivak, Seth
    Lancia, Michael
    Drillio, Robert
    Bonato, Paolo
    [J]. JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2011, 8
  • [5] Patient specific ankle-foot orthoses using rapid prototyping
    Constantinos Mavroidis
    Richard G Ranky
    Mark L Sivak
    Benjamin L Patritti
    Joseph DiPisa
    Alyssa Caddle
    Kara Gilhooly
    Lauren Govoni
    Seth Sivak
    Michael Lancia
    Robert Drillio
    Paolo Bonato
    [J]. Journal of NeuroEngineering and Rehabilitation, 8
  • [6] Passive-Dynamic Ankle-Foot Orthoses Substitute for Ankle Strength While Causing Adaptive Gait Strategies: A Feasibility Study
    Arch, Elisa S.
    Stanhope, Steven J.
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2015, 43 (02) : 442 - 450
  • [7] A PREDICTABLE AND REPEATABLE METHOD TO RAPIDLY MANUFACTURE FUNCTION-CUSTOMIZED PASSIVE-DYNAMIC ANKLE FOOT ORTHOSES
    Schrank, Elisa S.
    Razzook, Alexander
    Takahashi, Kota
    Tierney, John
    Gillespie, John W., Jr.
    Hitch, Lester
    Wallace, Kevin
    Moore, Rick
    Higginson, Jill S.
    Stanhope, Steven J.
    [J]. PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE, PTS A AND B, 2012, : 1237 - 1238
  • [8] State of the Prescription Process for Dynamic Ankle-Foot Orthoses
    Koller C.
    Arch E.S.
    [J]. Current Physical Medicine and Rehabilitation Reports, 2018, 6 (1) : 55 - 61
  • [9] A modified passive-dynamic ankle-foot orthosis: can it prevent amputation and arthrodesis in patients with ankle-foot trauma?
    Jonkergouw, Niels
    de Kruijff, Loes G. M.
    Bongers, Rogier E. G.
    Swaan, Michiel W.
    Holtslag, Herman R.
    van der Meer, Alfred
    van der Wurff, Peter
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2022, 142 (10) : 2719 - 2726
  • [10] Passive-dynamic ankle-foot orthoses change post-stroke lower extremity constituent work profile
    Skigen, Jacob T.
    Koller, Corey A.
    Reisman, Darcy S.
    McKee, Zahra N.
    Pinhey, Shay R.
    Wilken, Jason M.
    Arch, Elisa S.
    [J]. Journal of Biomechanics, 2024, 177