MEASUREMENT OF WALL SHEAR STRESS EXERTED BY FLOWING BLOOD IN THE HUMAN CAROTID ARTERY: ULTRASOUND DOPPLER VELOCIMETRY AND ECHO PARTICLE IMAGE VELOCIMETRY

被引:39
|
作者
Gates, Phillip E. [1 ,2 ]
Gurung, Arati [3 ]
Mazzaro, Luciano [3 ]
Aizawa, Kuni [1 ,2 ]
Elyas, Salim [1 ,2 ]
Strain, William D. [1 ,2 ]
Shore, Angela C. [1 ,2 ]
Shandas, Robin [3 ]
机构
[1] Univ Exeter, Sch Med, Natl Inst Hlth Res NIHR, Exeter Clin Res Facil, Exeter, Devon, England
[2] Univ Exeter, Sch Med, Diabet & Vasc Med Res Ctr, Exeter, Devon, England
[3] Univ Colorado Denver, Dept Bioengn, Aurora, CO USA
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2018年 / 44卷 / 07期
基金
美国国家卫生研究院;
关键词
Ultrasound; Echo particle image velocimetry; Ultrasound imaging velocimetry; Blood flow; Hemodynamics; Vasculr; VASCULAR ENDOTHELIAL-CELLS; IN-VIVO VALIDATION; SPATIAL GRADIENTS; STEADY SHEAR; VELOCITY; VITRO; ATHEROSCLEROSIS; SYSTEM; MRI; PIV;
D O I
10.1016/j.ultrasmedbio.2018.02.013
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Vascular endothelial cells lining the arteries are sensitive to wall shear stress (WSS) exerted by flowing blood. An important component of the pathophysiology of vascular diseases, WSS is commonly estimated by centerline ultrasound Doppler velocimetry (UDV). However, the accuracy of this method is uncertain. We have previously validated the use of a novel, ultrasound-based, particle image velocimetry technique (echo PIV) to compute 2-D velocity vector fields, which can easily be converted into WSS data. We compared WSS data derived from UDV and echo PIV in the common carotid artery of 27 healthy participants. Compared with echo PIV, time-averaged WSS was lower using UDV (28 +/- 35%). Echo PIV revealed that this was due to considerable spatiotemporal variation in the flow velocity profile, contrary to the assumption that flow is steady and the velocity profile is parabolic throughout the cardiac cycle. The largest WSS underestimation by UDV was found during peak systole (118 +/- 16%) and the smallest during mid-diastole (4.3 +/- 46%). The UDV method underestimated WSS for the accelerating and decelerating systolic measurements (68 +/- 30% and 24 +/- 51%), whereas WSS was overestimated for end-diastolic measurements (-44 +/- 55%). Our data indicate that UDV estimates of WSS provided limited and largely inaccurate information about WSS and that the complex spatiotemporal flow patterns do not fit well with traditional assumptions about blood flow in arteries. Echo PIV-derived WSS provides detailed information about this important but poorly understood stimulus that influences vascular endothelial pathophysiology. (c) 2018 World Federation for Ultrasound in Medicine & Biology. All rights reserved.
引用
收藏
页码:1392 / 1401
页数:10
相关论文
共 50 条
  • [41] Micro-ultrasound biofluid imaging and multi-component velocity measurement with Micro Echo Particle Image Velocimetry technique
    Qian, Ming
    Yan, Liang
    Niu, Lili
    Jin, Qiaofeng
    Ling, Tao
    Chen, Yun
    Zheng, Hairong
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 451 - +
  • [42] Time-Resolved Particle Image Velocimetry Measurements with Wall Shear Stress and Uncertainty Quantification for the FDA Nozzle Model
    Raben, Jaime S.
    Hariharan, Prasanna
    Robinson, Ronald
    Malinauskas, Richard
    Vlachos, Pavlos P.
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2016, 7 (01) : 7 - 22
  • [43] Transitional flow analysis in the carotid artery bifurcation by proper orthogonal decomposition and particle image velocimetry
    Kefayati, Sarah
    Poepping, Tamie L.
    MEDICAL ENGINEERING & PHYSICS, 2013, 35 (07) : 898 - 909
  • [44] Investigation of flow and turbulence in carotid artery models of varying compliance using particle image velocimetry
    DiCarlo, A. L.
    Poepping, T.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 1743 - 1746
  • [45] Optimized Time-Resolved Echo Particle Image Velocimetry-Particle Tracking Velocimetry Measurements Elucidate Blood Flow in Patients With Left Ventricular Thrombus
    Sampath, Kaushik
    Harfi, Thura T.
    George, Richard T.
    Katz, Joseph
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2018, 140 (04):
  • [46] Advantages in using multi-frequency driving ultrasound for optimizing echo particle image velocimetry techniques
    Zheng, HR
    Mukdadi, O
    Hertzberg, J
    Shandas, R
    BIOMEDICAL SCIENCES INSTRUMENTATION, VOL 40, 2004, 449 : 371 - 376
  • [47] Estimation of the turbulent viscous shear stress in a centrifugal rotary blood pump by the large eddy particle image velocimetry method
    Jing-jing Ji
    Hao-yuan Li
    Qing-yu Wu
    Yu Zhang
    Xian-wu Luo
    Journal of Hydrodynamics, 2020, 32 : 486 - 496
  • [48] Estimation of the turbulent viscous shear stress in a centrifugal rotary blood pump by the large eddy particle image velocimetry method
    Ji, Jing-jing
    Li, Hao-yuan
    Wu, Qing-yu
    Zhang, Yu
    Luo, Xian-wu
    JOURNAL OF HYDRODYNAMICS, 2020, 32 (03) : 486 - 496
  • [49] ACCOUNTING FOR DIFFERENCES BETWEEN ECHO PARTICLE IMAGE VELOCIMETRY (EPIV) AND PULSE WAVE DOPPLER (PWD) VELOCITY MEASUREMENTS
    Walker, Andrew M.
    Johnston, Clifton R.
    Dobson, Gary M.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2009, PT A AND B, 2009, : 1085 - 1086
  • [50] In-Vitro Investigation of three-dimensional Carotid Artery Haemodynamics by Tomographic Particle Image Velocimetry
    Buchmann, N. A.
    Atkinson, C. H.
    Jermy, M. C.
    Soria, J.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 1665 - 1668