MEASUREMENT OF WALL SHEAR STRESS EXERTED BY FLOWING BLOOD IN THE HUMAN CAROTID ARTERY: ULTRASOUND DOPPLER VELOCIMETRY AND ECHO PARTICLE IMAGE VELOCIMETRY

被引:39
|
作者
Gates, Phillip E. [1 ,2 ]
Gurung, Arati [3 ]
Mazzaro, Luciano [3 ]
Aizawa, Kuni [1 ,2 ]
Elyas, Salim [1 ,2 ]
Strain, William D. [1 ,2 ]
Shore, Angela C. [1 ,2 ]
Shandas, Robin [3 ]
机构
[1] Univ Exeter, Sch Med, Natl Inst Hlth Res NIHR, Exeter Clin Res Facil, Exeter, Devon, England
[2] Univ Exeter, Sch Med, Diabet & Vasc Med Res Ctr, Exeter, Devon, England
[3] Univ Colorado Denver, Dept Bioengn, Aurora, CO USA
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2018年 / 44卷 / 07期
基金
美国国家卫生研究院;
关键词
Ultrasound; Echo particle image velocimetry; Ultrasound imaging velocimetry; Blood flow; Hemodynamics; Vasculr; VASCULAR ENDOTHELIAL-CELLS; IN-VIVO VALIDATION; SPATIAL GRADIENTS; STEADY SHEAR; VELOCITY; VITRO; ATHEROSCLEROSIS; SYSTEM; MRI; PIV;
D O I
10.1016/j.ultrasmedbio.2018.02.013
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Vascular endothelial cells lining the arteries are sensitive to wall shear stress (WSS) exerted by flowing blood. An important component of the pathophysiology of vascular diseases, WSS is commonly estimated by centerline ultrasound Doppler velocimetry (UDV). However, the accuracy of this method is uncertain. We have previously validated the use of a novel, ultrasound-based, particle image velocimetry technique (echo PIV) to compute 2-D velocity vector fields, which can easily be converted into WSS data. We compared WSS data derived from UDV and echo PIV in the common carotid artery of 27 healthy participants. Compared with echo PIV, time-averaged WSS was lower using UDV (28 +/- 35%). Echo PIV revealed that this was due to considerable spatiotemporal variation in the flow velocity profile, contrary to the assumption that flow is steady and the velocity profile is parabolic throughout the cardiac cycle. The largest WSS underestimation by UDV was found during peak systole (118 +/- 16%) and the smallest during mid-diastole (4.3 +/- 46%). The UDV method underestimated WSS for the accelerating and decelerating systolic measurements (68 +/- 30% and 24 +/- 51%), whereas WSS was overestimated for end-diastolic measurements (-44 +/- 55%). Our data indicate that UDV estimates of WSS provided limited and largely inaccurate information about WSS and that the complex spatiotemporal flow patterns do not fit well with traditional assumptions about blood flow in arteries. Echo PIV-derived WSS provides detailed information about this important but poorly understood stimulus that influences vascular endothelial pathophysiology. (c) 2018 World Federation for Ultrasound in Medicine & Biology. All rights reserved.
引用
收藏
页码:1392 / 1401
页数:10
相关论文
共 50 条
  • [21] Ultrasound flow phantom for transcranial Doppler: An assessment of angular mismatch effect on blood velocity measurement in comparison to optical particle image velocimetry
    Hashuro, Muhammad Shiddiq Sayyid
    Daibo, Kotaro
    Ishii, Takuro
    Saijo, Yoshifumi
    Ohta, Makoto
    FRONTIERS IN PHYSICS, 2023, 11
  • [22] In Vitro Shear Stress Measurements Using Particle Image Velocimetry in a Family of Carotid Artery Models: Effect of Stenosis Severity, Plaque Eccentricity, and Ulceration
    Kefayati, Sarah
    Milner, Jaques S.
    Holdsworth, David W.
    Poepping, Tamie L.
    PLOS ONE, 2014, 9 (07):
  • [23] A novel technique towards investigating wall shear stress within the stent struts using particle image velocimetry
    Freidoonimehr, Navid
    Arjomandi, Maziar
    Zander, Anthony
    Chin, Rey
    EXPERIMENTS IN FLUIDS, 2021, 62 (06)
  • [24] A novel technique towards investigating wall shear stress within the stent struts using particle image velocimetry
    Navid Freidoonimehr
    Maziar Arjomandi
    Anthony Zander
    Rey Chin
    Experiments in Fluids, 2021, 62
  • [25] Particle Image Velocimetry Measurements of Bed-Shear Stress Induced By Wall-Bounded Swirling Jets
    Wei, Maoxing
    Chiew, Yee-Meng
    Cheng, Nian-Sheng
    JOURNAL OF ENGINEERING MECHANICS, 2020, 146 (06)
  • [26] In vitro high-frame-rate contrast-enhanced ultrasound particle image velocimetry in a carotid artery stent
    Hoving, Astrid M.
    Voorneveld, Jason
    de Vries, Evelien E.
    Jebbink, Erik Groot
    Versluis, Michel
    Bosch, Johan G.
    de Jong, Nico
    Mikhal, Julia
    de Borst, Gert J.
    Slump, Cornelis H.
    MEDICAL IMAGING 2018: ULTRASONIC IMAGING AND TOMOGRAPHY, 2018, 10580
  • [27] Ultra-fast ultrasound blood flow velocimetry for carotid artery with deep learning
    He, Bingbing
    Lei, Jian
    Lang, Xun
    Li, Zhiyao
    Cui, Wang
    Zhang, Yufeng
    ARTIFICIAL INTELLIGENCE IN MEDICINE, 2023, 144
  • [28] MEASUREMENT OF AIRFLOW IN TRACHEA USING PARTICLE IMAGE VELOCIMETRY AND LASER-DOPPLER ANEMOMETRY
    Belka, M.
    Jedelsky, J.
    Boiron, O.
    Bailly, L.
    Bertrand, E.
    Zaremba, M.
    Maly, M.
    Lizal, F.
    ENGINEERING MECHANICS 2014, 2014, : 72 - 75
  • [29] Ultrasound wave propagation in tissue and scattering from microbubbles for echo particle image velocimetry technique
    Mukdadi, O
    Shandas, R
    BIOMEDICAL SCIENCES INSTRUMENTATION, VOL 40, 2004, 449 : 364 - 370
  • [30] Determining Haemodynamic Wall Shear Stress in the Rabbit Aorta In Vivo Using Contrast-Enhanced Ultrasound Image Velocimetry
    Riemer, K.
    Rowland, E. M.
    Leow, C. H.
    Tang, M. X.
    Weinberg, P. D.
    ANNALS OF BIOMEDICAL ENGINEERING, 2020, 48 (06) : 1728 - 1739