MEASUREMENT OF WALL SHEAR STRESS EXERTED BY FLOWING BLOOD IN THE HUMAN CAROTID ARTERY: ULTRASOUND DOPPLER VELOCIMETRY AND ECHO PARTICLE IMAGE VELOCIMETRY

被引:39
|
作者
Gates, Phillip E. [1 ,2 ]
Gurung, Arati [3 ]
Mazzaro, Luciano [3 ]
Aizawa, Kuni [1 ,2 ]
Elyas, Salim [1 ,2 ]
Strain, William D. [1 ,2 ]
Shore, Angela C. [1 ,2 ]
Shandas, Robin [3 ]
机构
[1] Univ Exeter, Sch Med, Natl Inst Hlth Res NIHR, Exeter Clin Res Facil, Exeter, Devon, England
[2] Univ Exeter, Sch Med, Diabet & Vasc Med Res Ctr, Exeter, Devon, England
[3] Univ Colorado Denver, Dept Bioengn, Aurora, CO USA
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2018年 / 44卷 / 07期
基金
美国国家卫生研究院;
关键词
Ultrasound; Echo particle image velocimetry; Ultrasound imaging velocimetry; Blood flow; Hemodynamics; Vasculr; VASCULAR ENDOTHELIAL-CELLS; IN-VIVO VALIDATION; SPATIAL GRADIENTS; STEADY SHEAR; VELOCITY; VITRO; ATHEROSCLEROSIS; SYSTEM; MRI; PIV;
D O I
10.1016/j.ultrasmedbio.2018.02.013
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Vascular endothelial cells lining the arteries are sensitive to wall shear stress (WSS) exerted by flowing blood. An important component of the pathophysiology of vascular diseases, WSS is commonly estimated by centerline ultrasound Doppler velocimetry (UDV). However, the accuracy of this method is uncertain. We have previously validated the use of a novel, ultrasound-based, particle image velocimetry technique (echo PIV) to compute 2-D velocity vector fields, which can easily be converted into WSS data. We compared WSS data derived from UDV and echo PIV in the common carotid artery of 27 healthy participants. Compared with echo PIV, time-averaged WSS was lower using UDV (28 +/- 35%). Echo PIV revealed that this was due to considerable spatiotemporal variation in the flow velocity profile, contrary to the assumption that flow is steady and the velocity profile is parabolic throughout the cardiac cycle. The largest WSS underestimation by UDV was found during peak systole (118 +/- 16%) and the smallest during mid-diastole (4.3 +/- 46%). The UDV method underestimated WSS for the accelerating and decelerating systolic measurements (68 +/- 30% and 24 +/- 51%), whereas WSS was overestimated for end-diastolic measurements (-44 +/- 55%). Our data indicate that UDV estimates of WSS provided limited and largely inaccurate information about WSS and that the complex spatiotemporal flow patterns do not fit well with traditional assumptions about blood flow in arteries. Echo PIV-derived WSS provides detailed information about this important but poorly understood stimulus that influences vascular endothelial pathophysiology. (c) 2018 World Federation for Ultrasound in Medicine & Biology. All rights reserved.
引用
收藏
页码:1392 / 1401
页数:10
相关论文
共 50 条
  • [11] Tomographic particle image velocimetry investigation of the flow in a modeled human carotid artery bifurcation
    Buchmann, N. A.
    Atkinson, C.
    Jeremy, M. C.
    Soria, J.
    EXPERIMENTS IN FLUIDS, 2011, 50 (04) : 1131 - 1151
  • [12] Tomographic particle image velocimetry investigation of the flow in a modeled human carotid artery bifurcation
    N. A. Buchmann
    C. Atkinson
    M. C. Jeremy
    J. Soria
    Experiments in Fluids, 2011, 50 : 1131 - 1151
  • [13] Shear rates derived from ultrasound images and particle image velocimetry
    Clifton Johnston
    Melissa Lui
    Kogan Lee
    Andrew Walker
    Gary Dobson
    Canadian Journal of Anaesthesia, 2008, 55 (Suppl 1) : 4753841 - 4753842
  • [14] Ultrasound imaging velocimetry: Toward reliable wall shear stress measurements
    Poelma, C.
    van der Mijle, R. M. E.
    Mari, J. M.
    Tang, M. -X.
    Weinberg, P. D.
    Westerweel, J.
    EUROPEAN JOURNAL OF MECHANICS B-FLUIDS, 2012, 35 : 70 - 75
  • [15] Wall shear stress measurement of near-wall flow over inclined and curved boundaries by stereo interfacial particle image velocimetry
    Nguyen, Thien Duy
    Wells, John Craig
    Nguyen, Chuong Vinh
    INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2010, 31 (03) : 442 - 449
  • [16] Study of the effect of stenosis severity and non-Newtonian viscosity on multidirectional wall shear stress and flow disturbances in the carotid artery using particle image velocimetry
    DiCarlo, Amanda L.
    Holdsworth, David W.
    Poepping, Tamie L.
    MEDICAL ENGINEERING & PHYSICS, 2019, 65 : 8 - 23
  • [17] IN VITRO AND PRELIMINARY IN VIVO VALIDATION OF ECHO PARTICLE IMAGE VELOCIMETRY IN CAROTID VASCULAR IMAGING
    Zhang, Fuxing
    Lanning, Craig
    Mazzaro, Luciano
    Barker, Alex J.
    Gates, Phillip E.
    Strain, W. David
    Fulford, Jonathan
    Gosling, Oliver E.
    Shore, Angela C.
    Bellenger, Nick G.
    Rech, Bryan
    Chen, Jiusheng
    Chen, James
    Shandas, Robin
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2011, 37 (03): : 450 - 464
  • [18] MEASUREMENT OF CORONARY AND PERIPHERAL ARTERY FLOW BY INTRAVASCULAR ULTRASOUND AND PULSED DOPPLER VELOCIMETRY
    EICHHORN, EJ
    ALVAREZ, LG
    JESSEN, ME
    FASS, SM
    CHAO, RY
    HAAGEN, D
    GRAYBURN, PA
    AMERICAN JOURNAL OF CARDIOLOGY, 1992, 70 (04): : 542 - 545
  • [19] CONTRAST AGENT-FREE ASSESSMENT OF BLOOD FLOW AND WALL SHEAR STRESS IN THE RABBIT AORTA USING ULTRASOUND IMAGE VELOCIMETRY
    Riemer, Kai
    Rowland, Ethan M.
    Broughton-Venner, Jacob
    Leow, Chee Hau
    Tang, Mengxing
    Weinberg, P. D.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2022, 48 (03): : 437 - 449
  • [20] IN VIVO VALIDATION OF ECHO PARTICLE IMAGE VELOCIMETRY (ECHO PIV) IN HUMAN CAROTID ARTERIES USING PHASE-CONTRAST MRI
    Zhang, Fuxing
    Barker, Alex J.
    Gates, Phillip E.
    Strain, W. David
    Fulford, Jonathan
    Mazzaro, Luciano
    Shore, Angela C.
    Bellenger, Nick G.
    Lanning, Craig
    Shandas, Robin
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2009, PT A AND B, 2009, : 991 - 992