MEASUREMENT OF WALL SHEAR STRESS EXERTED BY FLOWING BLOOD IN THE HUMAN CAROTID ARTERY: ULTRASOUND DOPPLER VELOCIMETRY AND ECHO PARTICLE IMAGE VELOCIMETRY

被引:39
|
作者
Gates, Phillip E. [1 ,2 ]
Gurung, Arati [3 ]
Mazzaro, Luciano [3 ]
Aizawa, Kuni [1 ,2 ]
Elyas, Salim [1 ,2 ]
Strain, William D. [1 ,2 ]
Shore, Angela C. [1 ,2 ]
Shandas, Robin [3 ]
机构
[1] Univ Exeter, Sch Med, Natl Inst Hlth Res NIHR, Exeter Clin Res Facil, Exeter, Devon, England
[2] Univ Exeter, Sch Med, Diabet & Vasc Med Res Ctr, Exeter, Devon, England
[3] Univ Colorado Denver, Dept Bioengn, Aurora, CO USA
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2018年 / 44卷 / 07期
基金
美国国家卫生研究院;
关键词
Ultrasound; Echo particle image velocimetry; Ultrasound imaging velocimetry; Blood flow; Hemodynamics; Vasculr; VASCULAR ENDOTHELIAL-CELLS; IN-VIVO VALIDATION; SPATIAL GRADIENTS; STEADY SHEAR; VELOCITY; VITRO; ATHEROSCLEROSIS; SYSTEM; MRI; PIV;
D O I
10.1016/j.ultrasmedbio.2018.02.013
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Vascular endothelial cells lining the arteries are sensitive to wall shear stress (WSS) exerted by flowing blood. An important component of the pathophysiology of vascular diseases, WSS is commonly estimated by centerline ultrasound Doppler velocimetry (UDV). However, the accuracy of this method is uncertain. We have previously validated the use of a novel, ultrasound-based, particle image velocimetry technique (echo PIV) to compute 2-D velocity vector fields, which can easily be converted into WSS data. We compared WSS data derived from UDV and echo PIV in the common carotid artery of 27 healthy participants. Compared with echo PIV, time-averaged WSS was lower using UDV (28 +/- 35%). Echo PIV revealed that this was due to considerable spatiotemporal variation in the flow velocity profile, contrary to the assumption that flow is steady and the velocity profile is parabolic throughout the cardiac cycle. The largest WSS underestimation by UDV was found during peak systole (118 +/- 16%) and the smallest during mid-diastole (4.3 +/- 46%). The UDV method underestimated WSS for the accelerating and decelerating systolic measurements (68 +/- 30% and 24 +/- 51%), whereas WSS was overestimated for end-diastolic measurements (-44 +/- 55%). Our data indicate that UDV estimates of WSS provided limited and largely inaccurate information about WSS and that the complex spatiotemporal flow patterns do not fit well with traditional assumptions about blood flow in arteries. Echo PIV-derived WSS provides detailed information about this important but poorly understood stimulus that influences vascular endothelial pathophysiology. (c) 2018 World Federation for Ultrasound in Medicine & Biology. All rights reserved.
引用
收藏
页码:1392 / 1401
页数:10
相关论文
共 50 条
  • [1] ECHO PARTICLE IMAGE VELOCIMETRY (ECHO PIV): A NOVEL ULTRASOUND-BASED METHOD FOR THE IN VIVO MEASUREMENT OF WALL SHEAR STRESS IN HUMAN CAROTID ARTERIES
    Gates, P. E.
    Zhang, F.
    Strain, W. D.
    Gosling, O. E.
    Mazzaro, L.
    Barker, A. J.
    Fulford, J.
    Shore, A. C.
    Bellenger, N. G.
    Lanning, C.
    Shandas, R.
    HYPERTENSION, 2009, 54 (05) : 1171 - 1171
  • [2] Arterial Wall Shear Stress Measurement In Vivo Using Echo Particle Image Velocimetry (Echo PIV)
    Aizawa, Kunihiko
    Gates, Phillip E.
    Strain, W. David
    Gosling, Oliver E.
    Mazzaro, Luciano
    Zhang, Fuxing
    Barker, Alex J.
    Fulford, Jon
    Shore, Angela C.
    Bellenger, Nick G.
    Lanning, Craig
    Shandas, Robin
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2011, 43 (05): : 743 - 744
  • [3] Wall shear stress measurement in a turbulent pipe flow using ultrasound Doppler velocimetry
    Nowak, M
    EXPERIMENTS IN FLUIDS, 2002, 33 (02) : 249 - 255
  • [4] Wall shear stress measurement in a turbulent pipe flow using ultrasound Doppler velocimetry
    M. Nowak
    Experiments in Fluids, 2002, 33 : 249 - 255
  • [5] ECHO PARTICLE IMAGE VELOCIMETRY FOR ESTIMATION OF CAROTID ARTERY WALL SHEAR STRESS: REPEATABILITY, REPRODUCIBILITY AND COMPARISON WITH PHASE-CONTRAST MAGNETIC RESONANCE IMAGING
    Gurung, Arati
    Gates, Phillip E.
    Mazzaro, Luciano
    Fulford, Jonathan
    Zhang, Fuxing
    Barker, Alex J.
    Hertzberg, Jean
    Aizawa, Kunihiko
    Strain, William D.
    Elyas, Salim
    Shore, Angela C.
    Shandas, Robin
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (08): : 1618 - 1627
  • [6] Measuring wall shear stress distribution in the carotid artery in an African population: Computational fluid dynamics versus ultrasound doppler velocimetry
    Onwuzu, S. W. I.
    Ugwu, A. C.
    Mbah, G. C. E.
    Elo, I. S.
    RADIOGRAPHY, 2021, 27 (02) : 581 - 588
  • [7] Blood flow velocity and wall shear stress estimation in forward-viewing intravascular ultrasound imaging: Comparison of Doppler and Particle Image Velocimetry (PIV) approaches
    Kim, Saeyoung
    Jing, Bowen
    Veneziani, Alessandro
    Lindsey, Brooks D.
    INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS 2021), 2021,
  • [8] Investigation of the effect of geometrical features of carotid artery plaque on turbulence intensity using Doppler ultrasound and particle image velocimetry
    Kefayati, Sarah
    Powell, Janet L.
    Wong, Emily Y.
    Poepping, Tamie L.
    2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012, : 1607 - 1610
  • [9] 4D Blood Flow and Wall Shear Stress measured using Volumetric Ultrasound Image Velocimetry
    Riemer, K.
    Toulemonde, M.
    Rowland, E. M.
    Leow, C. H.
    Tang, M-X
    Weinberg, P. D.
    PROCEEDINGS OF THE 2020 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2020,
  • [10] A Novel Ultrasound-based Wall Shear Stress Biomarker (Echo Particle Image Velocimetry) to Generate Hemodynamic Vascular Profiles in Carotid Arteries: Clinical Studies on 16 Healthy Subjects
    Zhang, Fuxing
    Gates, Phillip E.
    Strain, W. D.
    Gosling, Oliver E.
    Mazzaro, Luciano
    Barker, Alex J.
    Fulford, Jonathan
    Shore, Angela C.
    Bellenger, Nick G.
    Lanning, Craig
    Shandas, Robin
    CIRCULATION, 2009, 120 (18) : S1037 - S1037