Minimizing Pedicle Screw Pullout Risks A Detailed Biomechanical Analysis of Screw Design and Placement

被引:80
|
作者
Bianco, Rohan-Jean [1 ,2 ,3 ]
Arnoux, Pierre-Jean [3 ]
Wagnac, Eric [1 ,3 ]
Mac-Thiong, Jean-Marc [2 ,4 ,5 ]
Aubin, Carl-Eric [1 ,2 ,4 ]
机构
[1] Polytech Montreal, Dept Mech Engn, Montreal, PQ, Canada
[2] Sainte Justine Univ Hosp Ctr, Montreal, PQ, Canada
[3] Univ Aix Marseille 1, Lab Biomcca Appl, UMRT24 IFSTTAR, Marseille, France
[4] Univ Montreal, Dept Surg, Montreal, PQ, Canada
[5] Hop Sacre Coeur, Dept Surg, Montreal, PQ, Canada
来源
CLINICAL SPINE SURGERY | 2017年 / 30卷 / 03期
基金
加拿大自然科学与工程研究理事会;
关键词
finite element analysis; pedicle screw; pullout test; spinal instrumentation; FINITE-ELEMENT MODEL; INSERTIONAL TORQUE; FIXATION; BONE; INSTRUMENTATION; CALIBRATION; SCOLIOSIS; STRENGTH; FAILURE; TESTS;
D O I
10.1097/BSD.0000000000000151
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design: Detailed biomechanical analysis of the anchorage performance provided by different pedicle screw designs and placement strategies under pullout loading. Objective: To biomechanically characterize the specific effects of surgeon-specific pedicle screw design parameters on anchorage performance using a finite element model. Summary of Background Data: Pedicle screw fixation is commonly used in the treatment of spinal pathologies. However, there is little consensus on the selection of an optimal screw type, size, and insertion trajectory depending on vertebra dimension and shape. Methods: Different screw diameters and lengths, threads, and insertion trajectories were computationally tested using a design of experiment approach. A detailed finite element model of an L3 vertebra was created including elastoplastic bone properties and contact interactions with the screws. Loads and boundary conditions were applied to the screws to simulate axial pullout tests. Force-displacement responses and internal stresses were analyzed to determine the specific effects of each parameter. Results: The design of experiment analysis revealed significant effects (P<0.01) for all tested principal parameters along with the interactions between diameter and trajectory. Screw diameter had the greatest impact on anchorage performance. The best insertion trajectory to resist pullout involved placing the screw threads closer to the pedicle walls using the straightforward insertion technique, which showed the importance of the cortical layer grip. The simulated cylindrical single-lead thread screws presented better biomechanical anchorage than the conical dual-lead thread screws in axial loading conditions. Conclusions: The model made it possible to quantitatively measure the effects of both screw design characteristics and surgical choices, enabling to recommend strategies to improve single pedicle screw performance under axial loading.
引用
收藏
页码:E226 / E232
页数:7
相关论文
共 50 条
  • [31] Pedicle screw placement in patients with variant atlas pedicle
    Zhang, Qiang-Hua
    Li, Hai-Dong
    Min, Ji-Kang
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2016, 44 (04) : 931 - 939
  • [32] BIOMECHANICAL STUDY OF PEDICLE SCREW FIXATION STRENGTH: ASSOCIATION OF SCREW MALPOSITION AND SCREW INSERTION TORQUE
    Tsai, Tsung-Ting
    Chen, Yu-Hung
    Liao, Chao-Yaug
    Lin, Hsin-Tzu
    Liu, Mu-Yi
    Chen, Jin-Kai
    Lai, Po-Liang
    Tai, Ching-Lung
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2019, 19 (02)
  • [33] Static and cyclical biomechanical analysis of pedicle screw spinal constructs
    Cunningham, BW
    Sefter, JC
    Shono, Y
    McAfee, PC
    SPINE, 2000, 25 (06) : 1S - 12S
  • [34] STATIC AND CYCLICAL BIOMECHANICAL ANALYSIS OF PEDICLE SCREW SPINAL CONSTRUCTS
    CUNNINGHAM, BW
    SEFTER, JC
    SHONO, Y
    MCAFEE, PC
    SPINE, 1993, 18 (12) : 1677 - 1688
  • [35] BIOMECHANICAL ANALYSIS OF PEDICLE SCREW INSTRUMENTATION SYSTEMS IN A CORPECTOMY MODEL
    ASHMAN, RB
    GALPIN, RD
    CORIN, JD
    JOHNSTON, CE
    SPINE, 1989, 14 (12) : 1398 - 1405
  • [36] Biomechanical analysis of pedicle screw density in posterior spine instrumentation
    Vaudreuil, Nicholas
    Xue, Jingbo
    Bell, Kevin
    Dede, Ozgur
    CURRENT ORTHOPAEDIC PRACTICE, 2019, 30 (04): : 312 - 317
  • [37] Biomechanical Analysis of Pedicle Screw Fixation for Thoracolumbar Burst Fractures
    McDonnell, Matthew
    Shah, Kalpit N.
    Paller, David J.
    Thakur, Nikhil A.
    Koruprolu, Sarath
    Palumbo, Mark A.
    Daniels, Alan H.
    ORTHOPEDICS, 2016, 39 (03) : E514 - E518
  • [38] Biomechanical evaluation and preliminary clinical experience with an expansive pedicle screw design
    Cook, SD
    Salkeld, SL
    Whitecloud, TS
    Barbera, J
    JOURNAL OF SPINAL DISORDERS, 2000, 13 (03): : 230 - 236
  • [39] Biomechanical Problems Related to the Pedicle Screw System
    Mizuno, Tetsutaro
    Sakakibara, Toshihiko
    Yoshikawa, Takamasa
    Inaba, Tadashi
    Kato, Takaya
    Kasai, Yuichi
    TURKISH NEUROSURGERY, 2019, 29 (01) : 53 - 58
  • [40] Biomechanical study of rotational micromovement of the pedicle screw
    Mizuno, Tetsutaro
    Kasai, Yuichi
    Sakakibara, Toshihiko
    Yoshikawa, Takamasa
    Inaba, Tadashi
    SPRINGERPLUS, 2016, 5