BIOMECHANICAL ANALYSIS OF PEDICLE SCREW INSTRUMENTATION SYSTEMS IN A CORPECTOMY MODEL

被引:87
|
作者
ASHMAN, RB
GALPIN, RD
CORIN, JD
JOHNSTON, CE
机构
关键词
D O I
10.1097/00007632-198912000-00019
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
引用
收藏
页码:1398 / 1405
页数:8
相关论文
共 50 条
  • [1] Biomechanical analysis of pedicle screw density in posterior spine instrumentation
    Vaudreuil, Nicholas
    Xue, Jingbo
    Bell, Kevin
    Dede, Ozgur
    [J]. CURRENT ORTHOPAEDIC PRACTICE, 2019, 30 (04): : 312 - 317
  • [2] Biomechanical study of lumbar pedicle screws in a corpectomy model assessing significance of screw height
    Mikles, MR
    Asghar, FA
    Frankenburg, EP
    Scott, DS
    Graziano, GP
    [J]. JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2004, 17 (04): : 272 - 276
  • [3] Biomechanical evaluation of diagonal fixation in pedicle screw instrumentation
    Lim, TH
    Kim, JG
    Fujiwara, A
    Yoon, TT
    Lee, SC
    Ha, JW
    An, HS
    [J]. SPINE, 2001, 26 (22) : 2498 - 2503
  • [4] Biomechanical analysis of anterior instrumentation for lumbar corpectomy
    Faro, FD
    White, KK
    Ahn, JS
    Oka, RS
    Mahar, AT
    Bawa, M
    Farnsworth, CL
    Garfin, SR
    Newton, PO
    [J]. SPINE, 2003, 28 (22) : E468 - E471
  • [5] BIOMECHANICAL ANALYSIS OF ANTERIOR AND POSTERIOR INSTRUMENTATION SYSTEMS AFTER CORPECTOMY - A CALF-SPINE MODEL
    GURR, KR
    MCAFEE, PC
    SHIH, CM
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (08): : 1182 - 1192
  • [6] Biomechanical analysis of pedicle screw density in spinal instrumentation for scoliosis treatment: first results
    Wang, Xiaoyu
    Aubin, Carl-Eric
    Larson, A. Noelle
    Labelle, Hubert
    Parent, Stefan
    [J]. RESEARCH INTO SPINAL DEFORMITIES 8, 2012, 176 : 303 - 306
  • [7] Pedicle screw instrumentation of thoracolumbar burst fractures: Biomechanical evaluation of screw configuration with pedicle screws at the level of the fracture
    Bolesta, Michael J.
    Caron, Troy
    Chinthakunta, Suresh R.
    Vazifeh, Pedram Niknam
    Khalil, Saif
    [J]. INTERNATIONAL JOURNAL OF SPINE SURGERY, 2012, 6 : 200 - 205
  • [8] Double pedicle screw instrumentation in the osteoporotic spine - A biomechanical feasibility study
    Jiang, Liang
    Arlet, Vincent
    Beckman, Lorne
    Steffen, Thomas
    [J]. JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2007, 20 (06): : 430 - 435
  • [9] Biomechanical analysis of pedicle screw pullout strength
    Bianco, R-J.
    Arnoux, P-J.
    Mac-Thiong, J-M.
    Wagnac, E.
    Aubin, C-E.
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2013, 16 : 246 - 248
  • [10] Biomechanical evaluation of monosegmental pedicle instrumentation in a calf spine model and the role of fractured vertebrae in screw stability
    Wei, Fuxin
    Zhou, Zhiyu
    Wang, Le
    Liu, Shaoyu
    Zhong, Rui
    Liu, Xizhe
    Cui, Shangbin
    Pan, Ximin
    Gao, Manman
    Zhao, Yajing
    [J]. BMC VETERINARY RESEARCH, 2016, 12