Pseudodynamic tests on a full-scale 3-storey precast concrete building: Behavior of the mechanical connections and floor diaphragms

被引:107
|
作者
Bournas, Dionysios A. [1 ]
Negro, Paolo [2 ]
Molina, Francisco J. [2 ]
机构
[1] Univ Nottingham, Dep Civil Engn, Nottingham NG7 2RD, England
[2] Commiss European Communities, Joint Res Ctr, Inst Protect & Secur Citizen, European Lab Struct Assessment, I-21020 Ispra, VA, Italy
关键词
Precast concrete structures; Pseudodynamic tests; Safecast project; Beam-column joints; Diaphragm; Dry connections; Mechanical connections; Shear walls;
D O I
10.1016/j.engstruct.2013.05.046
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A full-scale three-storey precast building was tested under seismic conditions at the European Laboratory for Structural Assessment in the framework of the SAFECAST project. The unique research opportunity of testing a complete structural system was exploited to the maximum extent by subjecting the structure to a series of pseudodynamic (PsD) tests and by using four different structural layouts of the same mock-up, while 160 sensors were used to monitor the global and local response of each layout. Dry mechanical connections were adopted to realize the joints between: floor-to-floor, floor-to-beam, wall-to-structure; column (and wall)-to-foundation and beam-to-column. Particular emphasis was given to the seismic behavior of mechanical beam-column connections, as well as to the response of floor diaphragms. Thus, the in-plane rigidity of three pretopped diaphragms with or without openings was assessed. In addition, two types of beam-to-column connections were investigated experimentally, namely hinged beam-column connections by means of dowel bar and emulative beam-column joints by means of dry innovative mechanical connections. Therefore, the seismic behavior of floor diaphragms and pinned beam-column connections in a multi-storey precast building was addressed experimentally. The results demonstrated that the proposed new beam-to-column connection system is a viable solution toward enhancing the response of precast RC frames subjected to seismic loads, in particular when the system is applied to all joints and quality measures are enforced in the execution of the joints. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:609 / 627
页数:19
相关论文
共 50 条
  • [41] Thermo-mechanical behavior of driven energy piles from full-scale load tests
    Jiang, Gang
    Lin, Cheng
    Shao, Dong
    Huang, Mian
    Lu, Hongwei
    Chen, Gen
    Zong, Chenfeng
    ENERGY AND BUILDINGS, 2021, 233
  • [42] Full-scale experimental study on shear behavior of multiple-keyed epoxy joints in precast concrete segmental bridges
    Zhang, Yongping
    Zhang, Zhihao
    Hu, Fangjian
    Du, Xiaoqing
    Lu, Yuanchun
    Zhu, Jiongyi
    STRUCTURES, 2022, 45 : 437 - 447
  • [43] Finite element analysis and load tests of full-scale, variable-thickness precast, prestressed concrete pavement on granular base
    Alwehaidah, Nasser M.
    Russell, Bruce W.
    PCI JOURNAL, 2018, : 54 - 61
  • [44] Shake-Table Test of a Full-Scale 4-Story Precast Concrete Building. II: Analytical Studies
    Gavridou, Sofia
    Wallace, John W.
    Nagae, Takuya
    Matsumori, Taizo
    Tahara, Kenich
    Fukuyama, Kunio
    JOURNAL OF STRUCTURAL ENGINEERING, 2017, 143 (06)
  • [45] Low-Cyclic Reversed Loading Tests on Full-Scale Precast Concrete Composite Wall Connected by Tooth Groove and Grouted Sleeve
    Luo, Xiaoyong
    Chen, Qi
    Deng, Chao
    Luo, Wangcheng
    He, Yang
    MATERIALS, 2024, 17 (02)
  • [46] Shake-Table Test of a Full-Scale 4-Story Precast Concrete Building. I: Overview and Experimental Results
    Gavridou, Sofia
    Wallace, John W.
    Nagae, Takuya
    Matsumori, Taizo
    Tahara, Kenich
    Fukuyama, Kunio
    JOURNAL OF STRUCTURAL ENGINEERING, 2017, 143 (06)
  • [47] Full scale tests and a progressive failure model to simulate full mechanical behavior of concrete tunnel segmental lining joints
    Qiu, Yue
    Hu, Xiongyu
    Walton, Gabriel
    He, Cong
    He, Chuan
    Ju, J. Woody
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2021, 110
  • [48] Dynamic tests of the 9-story R/C full-scale building with an additional isolated upper floor acting as a vibration damper
    Melkumian, MG
    STRUCTURAL DYNAMICS, VOLS. 1 & 2, 1996, : 557 - 560
  • [49] Horizontal mechanical behavior of elastomeric bearings under eccentric vertical loading: Full-scale tests and analytical modeling
    Zhu Hongping
    Zhang Zixiang
    Zhou Fangyuan
    Luo Hui
    Deng Xuan
    CONSTRUCTION AND BUILDING MATERIALS, 2016, 125 : 574 - 584
  • [50] Flexural behavior of full-scale circular concrete members reinforced with basalt FRP bars and spirals: Tests and theoretical studies
    Mousa, Salaheldin
    Mohamed, Hamdy M.
    Benmokrane, Brahim
    Ferrier, Emmanuel
    COMPOSITE STRUCTURES, 2018, 203 : 217 - 232