Pseudodynamic tests on a full-scale 3-storey precast concrete building: Behavior of the mechanical connections and floor diaphragms

被引:107
|
作者
Bournas, Dionysios A. [1 ]
Negro, Paolo [2 ]
Molina, Francisco J. [2 ]
机构
[1] Univ Nottingham, Dep Civil Engn, Nottingham NG7 2RD, England
[2] Commiss European Communities, Joint Res Ctr, Inst Protect & Secur Citizen, European Lab Struct Assessment, I-21020 Ispra, VA, Italy
关键词
Precast concrete structures; Pseudodynamic tests; Safecast project; Beam-column joints; Diaphragm; Dry connections; Mechanical connections; Shear walls;
D O I
10.1016/j.engstruct.2013.05.046
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A full-scale three-storey precast building was tested under seismic conditions at the European Laboratory for Structural Assessment in the framework of the SAFECAST project. The unique research opportunity of testing a complete structural system was exploited to the maximum extent by subjecting the structure to a series of pseudodynamic (PsD) tests and by using four different structural layouts of the same mock-up, while 160 sensors were used to monitor the global and local response of each layout. Dry mechanical connections were adopted to realize the joints between: floor-to-floor, floor-to-beam, wall-to-structure; column (and wall)-to-foundation and beam-to-column. Particular emphasis was given to the seismic behavior of mechanical beam-column connections, as well as to the response of floor diaphragms. Thus, the in-plane rigidity of three pretopped diaphragms with or without openings was assessed. In addition, two types of beam-to-column connections were investigated experimentally, namely hinged beam-column connections by means of dowel bar and emulative beam-column joints by means of dry innovative mechanical connections. Therefore, the seismic behavior of floor diaphragms and pinned beam-column connections in a multi-storey precast building was addressed experimentally. The results demonstrated that the proposed new beam-to-column connection system is a viable solution toward enhancing the response of precast RC frames subjected to seismic loads, in particular when the system is applied to all joints and quality measures are enforced in the execution of the joints. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:609 / 627
页数:19
相关论文
共 50 条
  • [21] The Effect of Stiffened Floor and Roof Diaphragms on the Experimental Seismic Response of a Full-Scale Unreinforced Stone Masonry Building
    Senaldi, Ilaria
    Magenes, Guido
    Penna, Andrea
    Galasco, Alessandro
    Rota, Maria
    JOURNAL OF EARTHQUAKE ENGINEERING, 2014, 18 (03) : 407 - 443
  • [22] Cyclic testing of a full-scale two-storey reinforced precast concrete wall-slab-wall structure
    Brunesi, E.
    Peloso, S.
    Pinho, R.
    Nascimbene, R.
    BULLETIN OF EARTHQUAKE ENGINEERING, 2018, 16 (11) : 5309 - 5339
  • [23] Cyclic testing of a full-scale two-storey reinforced precast concrete wall-slab-wall structure
    E. Brunesi
    S. Peloso
    R. Pinho
    R. Nascimbene
    Bulletin of Earthquake Engineering, 2018, 16 : 5309 - 5339
  • [24] Experimental behaviour of a full-scale timber-concrete composite floor with mechanical connectors
    Fragiacomo, Massimo
    MATERIALS AND STRUCTURES, 2012, 45 (11) : 1717 - 1735
  • [25] Experimental behaviour of a full-scale timber-concrete composite floor with mechanical connectors
    Massimo Fragiacomo
    Materials and Structures, 2012, 45 : 1717 - 1735
  • [26] Flexural behavior of precast insulated sandwich wall panels: Full-scale tests and design implications
    Hou, Hetao
    Ji, Kefan
    Wang, Wenhao
    Qu, Bing
    Fang, Mingji
    Qiu, Canxing
    ENGINEERING STRUCTURES, 2019, 180 : 750 - 761
  • [27] Effects of grouting defects on seismic behavior of full-scale precast reinforced concrete shear wall
    Cao, Dong
    Pan, Zuanfeng
    Zhen, Guanyu
    JOURNAL OF BUILDING ENGINEERING, 2023, 76
  • [28] Full-Scale Tests of Slender Concrete-Filled Tubes: Axial Behavior
    Perea, Tiziano
    Leon, Roberto T.
    Hajjar, Jerome F.
    Denavit, Mark D.
    JOURNAL OF STRUCTURAL ENGINEERING, 2013, 139 (07) : 1249 - 1262
  • [29] Full-Scale Tests of Slender Concrete-Filled Tubes: Interaction Behavior
    Perea, Tiziano
    Leon, Roberto T.
    Hajjar, Jerome F.
    Denavit, Mark D.
    JOURNAL OF STRUCTURAL ENGINEERING, 2014, 140 (09)
  • [30] Investigation on in-plane mechanical behavior of joint connections for discrete connected new-type precast concrete diaphragms
    Zhao, Wan
    Pang, Rui
    Liang, Shuting
    Zhu, Xiaojun
    MAGAZINE OF CONCRETE RESEARCH, 2022, 74 (21) : 1081 - 1096