Pseudodynamic tests on a full-scale 3-storey precast concrete building: Behavior of the mechanical connections and floor diaphragms

被引:107
|
作者
Bournas, Dionysios A. [1 ]
Negro, Paolo [2 ]
Molina, Francisco J. [2 ]
机构
[1] Univ Nottingham, Dep Civil Engn, Nottingham NG7 2RD, England
[2] Commiss European Communities, Joint Res Ctr, Inst Protect & Secur Citizen, European Lab Struct Assessment, I-21020 Ispra, VA, Italy
关键词
Precast concrete structures; Pseudodynamic tests; Safecast project; Beam-column joints; Diaphragm; Dry connections; Mechanical connections; Shear walls;
D O I
10.1016/j.engstruct.2013.05.046
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A full-scale three-storey precast building was tested under seismic conditions at the European Laboratory for Structural Assessment in the framework of the SAFECAST project. The unique research opportunity of testing a complete structural system was exploited to the maximum extent by subjecting the structure to a series of pseudodynamic (PsD) tests and by using four different structural layouts of the same mock-up, while 160 sensors were used to monitor the global and local response of each layout. Dry mechanical connections were adopted to realize the joints between: floor-to-floor, floor-to-beam, wall-to-structure; column (and wall)-to-foundation and beam-to-column. Particular emphasis was given to the seismic behavior of mechanical beam-column connections, as well as to the response of floor diaphragms. Thus, the in-plane rigidity of three pretopped diaphragms with or without openings was assessed. In addition, two types of beam-to-column connections were investigated experimentally, namely hinged beam-column connections by means of dowel bar and emulative beam-column joints by means of dry innovative mechanical connections. Therefore, the seismic behavior of floor diaphragms and pinned beam-column connections in a multi-storey precast building was addressed experimentally. The results demonstrated that the proposed new beam-to-column connection system is a viable solution toward enhancing the response of precast RC frames subjected to seismic loads, in particular when the system is applied to all joints and quality measures are enforced in the execution of the joints. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:609 / 627
页数:19
相关论文
共 50 条
  • [31] Full-scale shaking table test of a reinforced concrete precast building with horizontal concrete cladding panels and a numerical simulation
    Gams, Matija
    Stares, Gabrijela
    Isakovic, Tatjana
    JOURNAL OF BUILDING ENGINEERING, 2022, 55
  • [32] Performance of Exterior Precast Concrete Cladding Panels in NEES-TIPS/E∼Defense Tests on a Full-Scale 5-Story Building
    McMullin, Kurt M.
    Kamau-Devers, Kanotha
    STRUCTURES CONGRESS 2017: BUSINESS, PROFESSIONAL PRACTICE, EDUCATION, RESEARCH, AND DISASTER MANAGEMENT, 2017, : 209 - 219
  • [33] Optimization of Mechanical Performance of Full-Scale Precast Concrete Pipes with Varying Concrete Strengths and Reinforcement Using Factorial Design
    Abbas, Safeer
    INFRASTRUCTURES, 2025, 10 (02)
  • [34] Experimental study on flexural behavior of full-scale precast prestressed concrete double-tee members
    Xiong X.
    Ge Y.
    Yao G.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2022, 43 (02): : 127 - 136and172
  • [35] Seismic performance of a full-scale five-story masonry-infilled RC building subjected to substructured pseudodynamic tests
    Kallioras, Stylianos
    Pohoryles, Daniel A.
    Bournas, Dionysios
    Molina, Francisco Javier
    Pegon, Pierre
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2023, 52 (12): : 3649 - 3678
  • [36] Pseudo-Dynamic Tests on a Full-Scale Four-Storey Reinforced Concrete Frame Seismically Retrofitted with Reinforced Concrete Infilling
    Chrysostomou, Christis Zenon
    Poljansek, Martin
    Kyriakides, Nicholas
    Taucer, Fabio
    Molina, Francisco Javier
    STRUCTURAL ENGINEERING INTERNATIONAL, 2013, 23 (02) : 159 - 166
  • [37] Fire behaviour of continuous reinforced concrete slabs in a full-scale multi-storey steel-framed building
    Li, B.
    Dong, Y. -L.
    Zhang, D. -S.
    FIRE SAFETY JOURNAL, 2015, 71 : 226 - 237
  • [38] Full-scale tests of precast concrete beam-column connections with composite T-beams and cast-in-place columns subjected to cyclic loading
    Xue, Weichen
    Yang, Xinlei
    Hu, Xiang
    STRUCTURAL CONCRETE, 2020, 21 (01) : 169 - 183
  • [39] Full-scale tests on pile supported floor slabs-steel fibre concrete only or in a combination with steel
    Hedebratt, J.
    Silfwerbrand, J.
    ISISS 2005: Innovation & Sustainability of Structures, Vol 1-3, 2005, : 437 - 448