Dose effect of guidewire position in intravascular brachytherapy

被引:7
|
作者
Shih, R
Hsu, WL
Li, XA
机构
[1] Univ Maryland, Dept Radiat Oncol, Baltimore, MD 21201 USA
[2] Tri Serv Gen Hosp, Dept Radiat Oncol, Taipei, Taiwan
[3] Natl Def Med Coll, Taipei, Taiwan
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2002年 / 47卷 / 10期
关键词
D O I
10.1088/0031-9155/47/10/309
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
It has been reported that the dose effects of metallic guidewires are significant in intravascular brachytherapy (IVBT) using a beta source. The Purpose Of this work is to investigate the dependence of these dose effects on guidewire position. The EGS4 Monte Carlo codes were used to perform the dose calculations for the Sr-90 (NOVOSTE). P-32 (Guidant) and Ir-192 (BEST Ind.) sources with and without a guidewire in place. Guidewires were placed at various distances from the central axes of the Sources. Due to the attenuation by the guidewires, a dose reduction of up to 70% behind a guidewire was observed for the beta sources. while the dose perturbation was found to be negligible for the gamma source. The dose reduction for the beta sources was found to be dependent on the guidewire location. For example, the close reduction was 10% higher for a stainless steel guidewire located at 0.5 mm than that for the guidewire at 2 mm from the central axis of the source, The portion of the target volume affected (shadowed) dosimetrically by the guidewire was reduced when the guidewire was positioned farther away from the source. The shadow volume (in which the dose reduction occurs) can be reduced by up to 45% as the guidewire is moved away from the source axis from 0.5 mm to 2 mm. The dosimetric perturbations due to the presence of a metallic guidewire as well as their dependence on guidewire location should be considered in designing a new IVBT delivery device. in analysing the treatment efficacy. and/or in dose prescription for a beta source.
引用
收藏
页码:1733 / 1740
页数:8
相关论文
共 50 条
  • [21] Complications of intravascular brachytherapy
    Wallner, Kent
    Kearney, Kathleen E.
    Azzalini, Lorenzo
    Kim, Edward Y.
    Parvathaneni, Upendra
    Sandison, George
    Lombardi, William L.
    Don, Creighton
    Kim, Minsun
    BRACHYTHERAPY, 2025, 24 (01) : 103 - 109
  • [22] A dwell position verification method for high dose rate brachytherapy
    Liu, L
    Prasad, S
    Bassano, D
    Heavern, J
    Keshler, B
    Hahn, S
    MEDICAL PHYSICS, 2004, 31 (06) : 1854 - 1854
  • [23] Radiochromic film dosimetry of a high dose rate beta source for intravascular brachytherapy
    Duggan, DM
    Coffey, CW
    Lobdell, JL
    Schell, MC
    MEDICAL PHYSICS, 1999, 26 (11) : 2461 - 2464
  • [24] Recommended dose calculation formalism and consensus dosimetry parameters for intravascular brachytherapy dosimetry
    Nath, R
    Chiu-Tsao, S
    Schaart, D
    Soares, C
    MEDICAL PHYSICS, 2004, 31 (06) : 1744 - 1745
  • [25] Longitudinal dose profile at vessel wall and prescription depths for an intravascular brachytherapy system
    Wong, P
    Xu, X
    MEDICAL PHYSICS, 2004, 31 (06) : 1899 - 1899
  • [26] The effects of non-centred catheter and guidewire on the dose distribution around source in catheter-based intravascular brachytherapy with 90Sr/90Y beta source
    Demir, B
    Demir, M
    Ahmed, AS
    RADIATION MEASUREMENTS, 2006, 41 (03) : 317 - 322
  • [27] Effects of vessel geometry and catheter position on dose delivery in intracoronary brachytherapy
    Wahle, A
    Lopez, JJ
    Pennington, EC
    Meeks, SL
    Braddy, KC
    Fox, JM
    Brennan, TMH
    Buatti, JM
    Rossen, JD
    Sonka, M
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2003, 50 (11) : 1286 - 1295
  • [28] Changes in applicator position with fractionated high dose rate gynaecological brachytherapy
    Hoskin, PJ
    Cook, M
    Bouscale, D
    Cansdale, J
    RADIOTHERAPY AND ONCOLOGY, 1996, 40 (01) : 59 - 62
  • [29] Calculated dose distributions of beta-particle sources used for intravascular brachytherapy.
    Fox, T
    Soares, C
    Crocker, I
    Brooks, K
    Davis, L
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (02): : 344 - 344
  • [30] Dose distributions for 90Y intravascular brachytherapy sources used with balloon catheters
    Piessens, M
    Reynaert, N
    Potempa, J
    Thierens, H
    Wijns, W
    Verbeke, L
    MEDICAL PHYSICS, 2002, 29 (07) : 1562 - 1571