Dose effect of guidewire position in intravascular brachytherapy

被引:7
|
作者
Shih, R
Hsu, WL
Li, XA
机构
[1] Univ Maryland, Dept Radiat Oncol, Baltimore, MD 21201 USA
[2] Tri Serv Gen Hosp, Dept Radiat Oncol, Taipei, Taiwan
[3] Natl Def Med Coll, Taipei, Taiwan
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2002年 / 47卷 / 10期
关键词
D O I
10.1088/0031-9155/47/10/309
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
It has been reported that the dose effects of metallic guidewires are significant in intravascular brachytherapy (IVBT) using a beta source. The Purpose Of this work is to investigate the dependence of these dose effects on guidewire position. The EGS4 Monte Carlo codes were used to perform the dose calculations for the Sr-90 (NOVOSTE). P-32 (Guidant) and Ir-192 (BEST Ind.) sources with and without a guidewire in place. Guidewires were placed at various distances from the central axes of the Sources. Due to the attenuation by the guidewires, a dose reduction of up to 70% behind a guidewire was observed for the beta sources. while the dose perturbation was found to be negligible for the gamma source. The dose reduction for the beta sources was found to be dependent on the guidewire location. For example, the close reduction was 10% higher for a stainless steel guidewire located at 0.5 mm than that for the guidewire at 2 mm from the central axis of the source, The portion of the target volume affected (shadowed) dosimetrically by the guidewire was reduced when the guidewire was positioned farther away from the source. The shadow volume (in which the dose reduction occurs) can be reduced by up to 45% as the guidewire is moved away from the source axis from 0.5 mm to 2 mm. The dosimetric perturbations due to the presence of a metallic guidewire as well as their dependence on guidewire location should be considered in designing a new IVBT delivery device. in analysing the treatment efficacy. and/or in dose prescription for a beta source.
引用
收藏
页码:1733 / 1740
页数:8
相关论文
共 50 条
  • [31] Novel dose calculation and characterization of 32P intravascular brachytherapy stent source
    Sadeghi, M.
    Kiavar, O.
    Saidi, P.
    Fatehi, R.
    KERNTECHNIK, 2011, 76 (05) : 367 - 372
  • [32] The real-time dose measurement scintillating fiber array for intravascular Brachytherapy procedures
    Guèye, P
    Harmon, C
    Tynes, L
    Keppel, C
    Kieper, D
    Onumah, N
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1855 - 1859
  • [33] Dose effects of stents in intravascular brachytherapy for in-stent restenosis: A Monte Carlo calculation
    Li, XA
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 55 (03): : 842 - 848
  • [34] Standards for intravascular brachytherapy dosimetry
    Soares, CG
    CELLULAR AND MOLECULAR BIOLOGY, 2002, 48 (05) : 441 - 443
  • [35] Radioactive stents for intravascular brachytherapy
    Duggan, DM
    Coffey, CW
    Gonzalez, AL
    Janicki, C
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 1577 - 1580
  • [36] Quality management for intravascular brachytherapy
    Thomadsen, B
    Chakri, A
    MEDICAL PHYSICS, 2002, 29 (06) : 1334 - 1334
  • [37] Intravascular brachytherapy of the coronary arteries
    Fox, RA
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (04): : R1 - R30
  • [38] The integral doses in the Intravascular Brachytherapy
    Tao, L
    Rakfal, S
    Wu, A
    MEDICAL PHYSICS, 2003, 30 (06) : 1333 - 1333
  • [39] Intravascular brachytherapy physics: Introduction
    Amols, HI
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 1573 - 1576
  • [40] Position sensitive silicon detectors for real time dosimetry and quality assurance of intravascular brachytherapy sources
    Caccia, M
    Cappellini, C
    Alemi, M
    Bulgheroni, A
    Novario, R
    Conte, L
    Bianchi, C
    Sampietro, C
    Grigoriev, E
    Kucewicz, W
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S27 - S27