Dosimetric Evaluation of Intensity Modulated Radiotherapy and Three-Dimensional Conformal Radiotherapy Treatment Plans for Prostate Cancer

被引:1
|
作者
Adeneye, Samuel [1 ]
Akpochafor, Michael [1 ]
Habeebu, Muhammad [1 ]
Omojola, Akintayo [3 ]
Joseph, Adedayo [2 ]
Awhariado, John [1 ]
Durosinnmi-Etti, Abayomi [2 ]
Aweda, Moses [1 ]
机构
[1] Univ Lagos, Coll Med, Dept Radiat Biol Radiotherapy & Radiodiag, Lagos, Nigeria
[2] Lagos Univ, Dept Radiotherapy, Nigerian Sovereign Investment Author, Teaching Hosp, Lagos, Nigeria
[3] Fed Med Ctr Asaba, Med Phys Unit, Dept Radiol, Asaba, Nigeria
来源
关键词
Conformity index; homogeneity index; intensity modulated radiotherapy; prostate cancer; 3D-conformal radiotherapy; RADIATION; IMRT; ARC;
D O I
10.5505/tjo.2020.2437
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
OBJECTIVE We evaluated the homogeneity index and conformity index using intensity modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3D-CRT) treatment plans in prostate cancer. METHODS Twenty treatment plans for ten patients were created using 3D-CRT of four-fields with gantry angles of 0 degrees, 90 degrees, 180 degrees, and 270 degrees; and IMRT of five-fields with gantry angles of 0 degrees, 72 degrees, 144 degrees, 216 degrees, and 288 degrees on an Eclipse Treatment Planning System (version 15.6). The volume of reference isodose, target volume, maximum isodose in the target, reference isodose, dose at 95% of planning target volume (PTV), dose at 2%, 5%, and 98% of PTV, and prescribed dose were collected from the dose volume histogram of each plan. The conformity index and homogeneity index (HI) were then calculated. The doses of the organs at risk were also collected and evaluated. RESULTS The HI of the twenty patients who underwent the treatment plan with 3D-CRT was 1.088 +/- 0.03, which shows good homogeneity, but less homogeneity when compared with plans done with IMRT (1.072 +/- 0.02). CONCLUSION The use of IMRT treatment plan for prostate cancer proved to be superior over 3D-CRT in terms of conformity and homogeneity, as well as sparring dose to organ at risk.
引用
收藏
页码:104 / 111
页数:8
相关论文
共 50 条
  • [31] 3-dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: Dosimetric and radiobiologic analysis
    Bhardwaj, A. K.
    Kehwar, T. S.
    Chakarvarti, S. K.
    Oinam, A. S.
    Sharma, S. C.
    IRANIAN JOURNAL OF RADIATION RESEARCH, 2007, 5 (01): : 1 - 8
  • [32] Dosimetric comparison of postoperative whole pelvic radiotherapy for endometrial cancer using three-dimensional conformal radiotherapy, intensity-modulated radiotherapy, and helical tomotherapy
    Yang, Ruijie
    Xu, Shouping
    Jiang, Weijuan
    Wang, Junjie
    Xie, Chuanbin
    ACTA ONCOLOGICA, 2010, 49 (02) : 230 - 236
  • [33] Dosimetric Comparisons of Three-dimensional Conformal Radiotherapy, Intensity-Modulated Radiotherapy, and Helical Tomotherapy in Whole Abdominopelvic Radiotherapy for Gynecologic Malignancy
    Kim, Yong Bae
    Kim, Joo Ho
    Jeong, Kyung Keun
    Seong, Jinsil
    Suh, Chang Ok
    Kim, Gwi Eon
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2009, 8 (05) : 369 - 377
  • [34] Retrospective analysis of intensity-modulated radiotherapy and three-dimensional conformal radiotherapy of postoperative treatment for biliary tract cancer
    Lee, Hyo Chun
    Lee, Jong Hoon
    Lee, Sea-Won
    Lee, Joo Hwan
    Yu, Mina
    Jang, Hong Seok
    Kim, Sung Hwan
    RADIATION ONCOLOGY JOURNAL, 2019, 37 (04): : 279 - 285
  • [35] The Risk of Secondary Malignancies as An Evaluation Factor in the Comparison of Prostate Cancer Intensity Modulated Radiotherapy (IMRT) and Conformal Radiotherapy (CRT) Treatment Plans
    Komisopoulos, G.
    Buckey, C.
    Stathakis, S.
    Sakellaropoulos, G.
    Kardamakis, D.
    Nikoforidis, G.
    Papanikolaou, N.
    Mavroidis, P.
    MEDICAL PHYSICS, 2015, 42 (06) : 3507 - 3507
  • [36] A RADIOTHERAPY PLANNING STUDY OF RAPIDARC, INTENSITY MODULATED RADIOTHERAPY AND THREE-DIMENSIONAL CONFORMAL RADIOTHERAPY IN THE TREATMENT OF PEDIATRIC RETROPERITONEAL TUMORS
    Shaffer, R.
    Vollans, E.
    Vellani, R.
    Welsh, M.
    Moiseenko, V.
    Goddard, K.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S370 - S370
  • [37] Dosimetric correlation of acute and late toxicities in high-risk prostate cancer patients treated with three-dimensional conformal radiotherapy followed by intensity modulated radiotherapy boost
    Kapoor, Rakesh
    Bansal, Anshuma
    Kumar, Narendra
    Oinam, Arun S.
    INDIAN JOURNAL OF UROLOGY, 2016, 32 (03) : 210 - 215
  • [38] Incidence of late rectal and urinary toxicities after three-dimensional conformal radiotherapy and intensity-modulated radiotherapy for localized prostate cancer
    Zelefsky, Michael J.
    Levin, Emily J.
    Hunt, Margie
    Yamada, Yoshiya
    Shippy, Alison M.
    Jackson, Andrew
    Amols, Howard I.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (04): : 1124 - 1129
  • [39] Three-dimensional conformal versus intensity modulated radiotherapy in breast cancer treatment: is necessary a medical reversal?
    Alba Fiorentino
    Ruggero Ruggieri
    Niccolò Giaj-Levra
    Gianluisa Sicignano
    Gioacchino Di Paola
    Stefania Naccarato
    Sergio Fersino
    Rosario Mazzola
    Umberto Tebano
    Francesco Ricchetti
    Filippo Alongi
    La radiologia medica, 2017, 122 : 146 - 153
  • [40] Three-dimensional conformal versus intensity modulated radiotherapy in breast cancer treatment: is necessary a medical reversal?
    Fiorentino, Alba
    Ruggieri, Ruggero
    Giaj-Levra, Niccolo
    Sicignano, Gianluisa
    Di Paola, Gioacchino
    Naccarato, Stefania
    Fersino, Sergio
    Mazzola, Rosario
    Tebano, Umberto
    Ricchetti, Francesco
    Alongi, Filippo
    RADIOLOGIA MEDICA, 2017, 122 (02): : 146 - 153