Dosimetric correlation of acute and late toxicities in high-risk prostate cancer patients treated with three-dimensional conformal radiotherapy followed by intensity modulated radiotherapy boost

被引:4
|
作者
Kapoor, Rakesh [1 ]
Bansal, Anshuma [1 ]
Kumar, Narendra [1 ]
Oinam, Arun S. [1 ]
机构
[1] Postgrad Inst Med Educ & Res, Dept Radiotherapy, Sect 12, Chandigarh, India
关键词
Correlation; dosimetry; high risk; intensity modulated radiotherapy; prostate cancer; three-dimensional conformal radiotherapy; toxicities;
D O I
10.4103/0970-1591.185098
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Introduction: In prostate cancer, higher radiation doses are often related to higher local control rates. However, the clinical effect of these higher doses on normal tissue toxicities is generally overlooked. We dosimetrically analyze sequential intensity modulated radiotherapy (IMRT) plans in high-risk prostate cancer patients and correlate them with acute and late normal tissue toxicities. Materials and Methods: Twenty-five high-risk prostate cancer patients were planned with three-dimensional conformal radiotherapy to a dose of 50 Gy delivered in 25 fractions in 5 weeks, followed by seven-field IMRT boost, to a dose of 24 Gy delivered in 12 fractions in 2.5 weeks, along with hormonal therapy. Acute and late toxicities were analyzed using Radiation Therapy Oncology Group toxicity criteria. Student's t-test was used for correlating doses received by normal tissues with toxicity grade. Five-year disease-free survival (DFS) and biochemical relapse-free survival (RFS) were evaluated using Kaplan-Meier analysis. Results: Median follow-up of patients was 65 months. Of 25 patients, two developed acute Grade 2 rectal toxicity. Only 1 patient developed acute Grade 2 bladder toxicity. Late Grade 2 and 3 rectal toxicity was seen in 2 and 1 patient, respectively. Late Grade 2 and 3 bladder toxicity was seen in 1 patient each. Grade 2 or more acute rectal toxicity correlated significantly with rectal volume receiving >70 Gy (P = 0.04). The 5-year DFS and biochemical RFS was 70.2% and 79.2%, respectively. One patient failed locally and seven failed at distant sites. Conclusion: Sequential IMRT with a dose of 74 Gy and maximum androgen blockade is well tolerated in high-risk patients in Indian setup with adequate control rates.
引用
收藏
页码:210 / 215
页数:6
相关论文
共 50 条
  • [1] A dosimetric evaluation of intensity modulated radiotherapy and three-dimensional conformal radiotherapy for prostate cancer in Ghana
    Kyei, Kofi Adesi
    Daniels, Joseph
    Adom, Ameyaw Kwame
    Odonkor, Philip
    Nyantakyi, Andrew Yaw
    Adjabu, Dorothy Ekua
    ECANCERMEDICALSCIENCE, 2024, 18
  • [2] Dosimetric Evaluation of Intensity Modulated Radiotherapy and Three-Dimensional Conformal Radiotherapy Treatment Plans for Prostate Cancer
    Adeneye, Samuel
    Akpochafor, Michael
    Habeebu, Muhammad
    Omojola, Akintayo
    Joseph, Adedayo
    Awhariado, John
    Durosinnmi-Etti, Abayomi
    Aweda, Moses
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2021, 36 (01): : 104 - 111
  • [3] Incidence of late rectal and urinary toxicities after three-dimensional conformal radiotherapy and intensity-modulated radiotherapy for localized prostate cancer
    Zelefsky, Michael J.
    Levin, Emily J.
    Hunt, Margie
    Yamada, Yoshiya
    Shippy, Alison M.
    Jackson, Andrew
    Amols, Howard I.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (04): : 1124 - 1129
  • [4] Dosimetric Comparison of Three-Dimensional Conformal Radiotherapy and Intensity Modulated Radiotherapy for Paediatric Neuroblastoma
    Jiang, M.
    PEDIATRIC BLOOD & CANCER, 2016, 63 : S196 - S196
  • [5] Dosimetric effect of Elekta Beam Modulator micromultileaf in three-dimensional conformal radiotherapy and intensity-modulated radiotherapy for prostate cancer
    Carosi, Alessandra
    Ingrosso, Gianluca
    Ponti, Elisabetta
    Tolu, Barbara
    Murgia, Alessandra
    di Cristino, Daniela
    Santoni, Riccardo
    MEDICAL DOSIMETRY, 2014, 39 (02) : 180 - 184
  • [6] A dosimetric comparison of intensity modulated radiotherapy versus three-dimensional conformal radiotherapy for esophageal carcinoma
    Jiang, Z.
    Zhou, L.
    Jiang, G.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S268 - S268
  • [7] Dosimetric comparison of three dimensional conformal radiotherapy and intensity modulated radiotherapy in high grade gliomas
    Sarkar, Biplab
    Goswami, Jyotirup
    Basu, Ayan
    Sriramprasath, S.
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2011, 17 (02) : 75 - 84
  • [8] CORRELATION BETWEEN ACUTE AND LATE TOXICITY IN 973 PROSTATE CANCER PATIENTS TREATED WITH THREE-DIMENSIONAL CONFORMAL EXTERNAL BEAM RADIOTHERAPY
    Jereczek-Fossa, Barbara A.
    Zerini, Dario
    Fodor, Cristiana
    Santoro, Luigi
    Serafini, Flavia
    Cambria, Raffaella
    Vavassori, Andrea
    Cattani, Federica
    Garibaldi, Cristina
    Gherardi, Federica
    Ferrari, Annamaria
    Rocco, Bernardo
    Scardino, Epifanio
    de Cobelli, Ottavio
    Orecchia, Roberto
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (01): : 26 - 34
  • [9] Dosimetric analysis of intensity-modulated radiotherapy and three-dimensional conformal radiotherapy for chest wall irradiation in breast cancer patients
    Kausar, Mehlam
    Gurjar, Om Prakash
    Bagdare, Priyusha
    Gupta, Krishna Lal
    Bhandari, Virendra
    Naik, Ayush
    Nag, Pulkit
    Kancherla, Jeetendra
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2016, 15 (01) : 30 - 37
  • [10] A Comparison of Gastrointestinal Toxicities between Intensity-Modulated Radiotherapy and Three-Dimensional Conformal Radiotherapy for Pancreatic Cancer
    Lee, Kyong Joo
    Yoon, Hong In
    Chung, Moon Jae
    Park, Jeong Youp
    Bang, Seungmin
    Park, Seung-woo
    Seong, Jin Sil
    Song, Si Young
    GUT AND LIVER, 2016, 10 (02) : 303 - 309