Radiation protection for an intraoperative X-ray source compared to C-arm fluoroscopy

被引:14
|
作者
Schneider, Frank [1 ]
Clausen, Sven [1 ]
Jahnke, Anika [1 ]
Steil, Volker [1 ]
Bludau, Frederic [2 ]
Suetterlin, Marc [3 ]
Obertacke, Udo [2 ]
Wenz, Frederik [1 ]
机构
[1] Heidelberg Univ, Univ Med Ctr Mannheim, Dept Radiat Oncol, D-68167 Mannheim, Germany
[2] Heidelberg Univ, Univ Med Ctr Mannheim, Dept Trauma Surg, D-68167 Mannheim, Germany
[3] Heidelberg Univ, Univ Med Ctr Mannheim, Dept Obstet & Gynaecol, D-68167 Mannheim, Germany
来源
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK | 2014年 / 24卷 / 03期
关键词
intraoperative radiotherapy; Intrabeam; radiation protection; SOCIETY CONSENSUS GUIDELINES; AMERICAN BRACHYTHERAPY; BREAST-CANCER; INTERSTITIAL RADIOSURGERY; RADIOTHERAPY-TARGIT; KYPHO-IORT; KYPHOPLASTY; DEVICE; DOSIMETRY;
D O I
10.1016/j.zemedi.2013.10.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Intraoperative radiotherapy (IORT) using the INTRABEAM (R) system promises a flexible use regarding radiation protection compared to other approaches such as electron treatment or HDR brachytherapy with Ir-192 or Co-60. In this study we compared dose rate measurements of breast- and Kypho-IORT with C-arm fluoroscopy which is needed to estimate radiation protection areas. Materials and Methods: C-arm fluoroscopy, breast- and Kypho-IORTs were performed using phantoms (silicon breast or bucket of water). Dose rates were measured at the phantom's surface, at 30 cm, 100 cm and 200 cm distance. Those measurements were confirmed during 10 Kypho-IORT and 10 breast-IORT patient treatments. Results: The measured dose rates were in the same magnitude for all three paradigms and ranges from 20 mu Sv/h during a simulated breast-IORT at two meter distance up to 64 mSv/h directly at the surface of a simulated Kypho-IORT. Those measurements result in a circle of controlled area (yearly doses >6 mSv) for each paradigm of about 4 m +/- 2 m. Discussion/Conclusions: All three paradigms show comparable dose rates which implies that the radiation protection is straight forward and confirms the flexible use of the INTRABEAM (R) system.
引用
收藏
页码:243 / 251
页数:9
相关论文
共 50 条
  • [1] Virtual fluoroscopy for intraoperative C-arm positioning and radiation dose reduction
    De Silva, Tharindu
    Punnoose, Joshua
    Uneri, Ali
    Mahesh, Mahadevappa
    Goerres, Joseph
    Jacobson, Matthew
    Ketcha, Michael D.
    Manbachi, Amir
    Vogt, Sebastian
    Kleinszig, Gerhard
    Khanna, Akhil Jay
    Wolinksy, Jean-Paul
    Siewerdsen, Jeffrey H.
    Osgood, Greg
    [J]. JOURNAL OF MEDICAL IMAGING, 2018, 5 (01)
  • [2] Analysis of radiation risk to patients from intraoperative use of the mobile X-ray system (C-arm)
    Lee, Yang-Sub
    Lee, Hae-Kag
    Cho, Jae-Hwan
    Kim, Ham-Gyum
    [J]. JOURNAL OF RESEARCH IN MEDICAL SCIENCES, 2015, 20 (01): : 7 - 12
  • [3] Utility of Intraoperative C-Arm Fluoroscopy for Frontal Sinusotomy
    Lee, Seung-Sin
    [J]. EWHA MEDICAL JOURNAL, 2009, 32 (02): : 61 - 64
  • [4] Calibration Method of Projectional Geometry for X-ray C-arm Fluoroscopy Using Sinogram Data
    Lee, Donggi
    Kim, Sungmin
    [J]. APPLIED SCIENCES-BASEL, 2022, 12 (15):
  • [5] C-ARM FLUOROSCOPY
    COHEN, MD
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (03) : 646 - 647
  • [6] Intraoperative assessment of hindfoot alignment using C-arm fluoroscopy
    Park, Young Uk
    Lee, Jong Wha
    Chung, Jun Young
    Choi, Wan-Sun
    Kim, Taehun
    Seo, Young Wook
    [J]. JOURNAL OF ORTHOPAEDIC SCIENCE, 2024, 29 (05) : 1248 - 1254
  • [7] Survey of terminology used for the intraoperative direction of C-arm fluoroscopy
    Pally, Elliott
    Kreder, Hans J.
    [J]. CANADIAN JOURNAL OF SURGERY, 2013, 56 (02) : 109 - 112
  • [8] Assessment of Radiation Protection in Hand-Shielding Products With Mini C-Arm Fluoroscopy
    Cantlon, Matthew B.
    Ilyas, Asif M.
    [J]. HAND-AMERICAN ASSOCIATION FOR HAND SURGERY, 2021, 16 (04): : 505 - 510
  • [9] X-ray Source for Intraoperative Radiation Therapy
    Dmitriev, A. S.
    Timofeev, G. A.
    Potrakhov, N. N.
    Potrakhov, E. N.
    Guk, K. K.
    Gryaznov, A. Yu
    Kholopova, E. D.
    [J]. 5TH INTERNATIONAL CONFERENCE ON X-RAY, ELECTROVACUUM AND BIOMEDICAL TECHNIQUE, 2019, 2089
  • [10] Measurements of Surgeons' Exposure to Ionizing Radiation Dose During Intraoperative Use of C-Arm Fluoroscopy
    Lee, Kisung
    Lee, Kyoung Min
    Park, Moon Seok
    Lee, Boram
    Kwon, Dae Gyu
    Chung, Chin Youb
    [J]. SPINE, 2012, 37 (14) : 1240 - 1244