Radiation protection for an intraoperative X-ray source compared to C-arm fluoroscopy

被引:14
|
作者
Schneider, Frank [1 ]
Clausen, Sven [1 ]
Jahnke, Anika [1 ]
Steil, Volker [1 ]
Bludau, Frederic [2 ]
Suetterlin, Marc [3 ]
Obertacke, Udo [2 ]
Wenz, Frederik [1 ]
机构
[1] Heidelberg Univ, Univ Med Ctr Mannheim, Dept Radiat Oncol, D-68167 Mannheim, Germany
[2] Heidelberg Univ, Univ Med Ctr Mannheim, Dept Trauma Surg, D-68167 Mannheim, Germany
[3] Heidelberg Univ, Univ Med Ctr Mannheim, Dept Obstet & Gynaecol, D-68167 Mannheim, Germany
来源
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK | 2014年 / 24卷 / 03期
关键词
intraoperative radiotherapy; Intrabeam; radiation protection; SOCIETY CONSENSUS GUIDELINES; AMERICAN BRACHYTHERAPY; BREAST-CANCER; INTERSTITIAL RADIOSURGERY; RADIOTHERAPY-TARGIT; KYPHO-IORT; KYPHOPLASTY; DEVICE; DOSIMETRY;
D O I
10.1016/j.zemedi.2013.10.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Intraoperative radiotherapy (IORT) using the INTRABEAM (R) system promises a flexible use regarding radiation protection compared to other approaches such as electron treatment or HDR brachytherapy with Ir-192 or Co-60. In this study we compared dose rate measurements of breast- and Kypho-IORT with C-arm fluoroscopy which is needed to estimate radiation protection areas. Materials and Methods: C-arm fluoroscopy, breast- and Kypho-IORTs were performed using phantoms (silicon breast or bucket of water). Dose rates were measured at the phantom's surface, at 30 cm, 100 cm and 200 cm distance. Those measurements were confirmed during 10 Kypho-IORT and 10 breast-IORT patient treatments. Results: The measured dose rates were in the same magnitude for all three paradigms and ranges from 20 mu Sv/h during a simulated breast-IORT at two meter distance up to 64 mSv/h directly at the surface of a simulated Kypho-IORT. Those measurements result in a circle of controlled area (yearly doses >6 mSv) for each paradigm of about 4 m +/- 2 m. Discussion/Conclusions: All three paradigms show comparable dose rates which implies that the radiation protection is straight forward and confirms the flexible use of the INTRABEAM (R) system.
引用
收藏
页码:243 / 251
页数:9
相关论文
共 50 条
  • [41] C-arm fluoroscopy in orthopaedic surgical practice
    Ojodu I.
    Ogunsemoyin A.
    Hopp S.
    Pohlemann T.
    Ige O.
    Akinola O.
    European Journal of Orthopaedic Surgery & Traumatology, 2018, 28 (8) : 1563 - 1568
  • [42] Laser Targeting With C-Arm Fluoroscopy: Effect on Image Acquisition and Radiation Exposure
    Shuler, Franklin D.
    Daigre, Justin L.
    Danh Pham
    Kish, Vincent L.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2013, 27 (05) : E97 - E102
  • [43] Surgical outcomes of intraoperative O-arm versus C-arm fluoroscopy in occipitocervical fixation: a retrospective analysis
    Wada, Keiji
    Mori, Shunichi
    Shimamoto, Shuji
    Inoue, Tomohisa
    Tamaki, Ryo
    Okazaki, Ken
    BRITISH JOURNAL OF NEUROSURGERY, 2023,
  • [44] Radiation protection for an intra-operative X-ray source
    Schneider, F.
    Clausen, S.
    Klabes, A.
    Steil, V
    Bludau, F.
    Suetterlin, M.
    Obertacke, U.
    Wenz, F.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2012, 188 : 171 - 171
  • [45] Intraoperative C-Arm Radiation Affecting Factors and Reduction by an Intervention Program
    Bar-On, Elhanan
    Weigl, Daniel Martin
    Becker, Tali
    Katz, Kalman
    Konen, Osnat
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2010, 30 (04) : 320 - 323
  • [46] Radiation protection education in the use of mobile C-arm for the nurses
    Henner, Anja
    ACTA RADIOLOGICA, 2013, 54 (04) : 6 - 6
  • [47] Comparison of operator radiation exposure between C-arm and O-arm fluoroscopy for orthopaedic surgery
    Park, Moon Seok
    Lee, Kyoung Min
    Lee, Boram
    Min, Eunki
    Kim, Youhyun
    Jeon, Sungchae
    Huh, Young
    Lee, Kisung
    RADIATION PROTECTION DOSIMETRY, 2012, 148 (04) : 431 - 438
  • [48] Achieving super-resolution X-ray imaging with mobile C-arm devices
    Bodensteiner, C.
    Darolti, C.
    Schweikard, A.
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2009, 5 (03): : 243 - 256
  • [49] C-arm X-ray image mosaic using home-made ruler
    Chen, Diansheng
    Fan, Xing
    Hu, Lei
    Gaojishu Tongxin/Chinese High Technology Letters, 2006, 16 (10): : 1030 - 1033
  • [50] The Dose Rate Measurements of C-arm Fluoroscopic X-ray Systems with and without Apron
    Tuncel, Nina
    1ST INTERNATIONAL CONFERENCE ON RADIATIONS AND APPLICATIONS (ICRA-2017), 2018, 1994