Grey interrelated evaluation of indoor air quality in buildings

被引:0
|
作者
Wang, HQ [1 ]
Shi, SL [1 ]
机构
[1] Xiangtan Polytech Univ, Dept Resources Engn, Xiangtan 411201, Hunan, Peoples R China
关键词
modelling; 'Grey' method; interrelated degree;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, an analytical method for evaluating indoor air quality (IAQ) based on published values of prescribed upper limits for indoor air pollutants is presented. The method uses a 'grey' interrelated mathematical model developed from the 'grey interrelated theory'. The model has been applied to actual measurements taken in office buildings in Shanghai. The analytical method provides a simpler and more accurate way of evaluating IAQ than other models and it provides a new theoretical base for such evaluations. Copyright (C) 2000 S. Karger AG, Basel.
引用
收藏
页码:304 / 308
页数:5
相关论文
共 50 条
  • [1] Grey assessment of indoor air quality
    Zhu, CH
    Li, NP
    Wen, W
    [J]. PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 81 - 88
  • [2] Grey model of indoor air quality
    Zhu, C
    Li, N
    [J]. INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 2807 - 2812
  • [3] INDOOR AIR QUALITY OF THE OFFICE BUILDINGS
    Senitkova, Ingrid
    Tomcik, Tomas
    [J]. CESB 10: CENTRAL EUROPE TOWARDS SUSTAINABLE BUILDING - FROM THEORY TO PRACTICE, 2010, : 517 - 520
  • [4] Indoor air quality - buildings design
    Senitkova, Ingrid Juhasova
    [J]. 8TH INTERNATIONAL SCIENTIFIC CONFERENCE BUILDING DEFECTS (BUILDING DEFECTS 2016), 2016, 93
  • [5] Indoor air quality for residential buildings
    Sherman, M
    [J]. ASHRAE JOURNAL, 1999, 41 (05) : 26 - 30
  • [6] Measurement and evaluation of indoor air quality in naturally ventilated residential buildings
    Yin, Haiguo
    Liu, Chunxue
    Zhang, Leiming
    Li, Angui
    Ma, Zhenjun
    [J]. INDOOR AND BUILT ENVIRONMENT, 2019, 28 (10) : 1307 - 1323
  • [7] GREY EVALUATION MODEL OF INDOOR AIR QUALITY USING A COMBINATION WEIGHTING METHOD
    Zhang, Xutao
    Wang, Songling
    Wang, Jiangjiang
    Shi, Guohua
    [J]. FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 952 - 959
  • [8] Evaluation of Indoor Air Quality and Health Related Parameters in Office Buildings with or without Indoor Plants
    Kim, Ho-Hyun
    Lee, Jae-Young
    Yang, Ji-Yeon
    Kim, Kwang-Jin
    Lee, Yong-Jin
    Shin, Dong-Chun
    Lim, Young-Wook
    [J]. JOURNAL OF THE JAPANESE SOCIETY FOR HORTICULTURAL SCIENCE, 2011, 80 (01): : 96 - 102
  • [9] Ventilation and indoor air quality in office buildings
    Pan, YQ
    Long, WD
    Fan, CY
    [J]. INTERNATIONAL SYMPOSIUM ON AIR CONDITIONING IN HIGH RISE BUILDINGS '2000, PROCEEDINGS, 2000, 2000 (03): : 225 - 229
  • [10] Microbiological indoor air quality in healthy buildings
    Sessa, R
    Di Pietro, M
    Schiavoni, G
    Santino, I
    Altieri, A
    Pinelli, S
    Del Piano, M
    [J]. MICROBIOLOGICA, 2002, 25 (01): : 51 - 56