Grey assessment of indoor air quality

被引:0
|
作者
Zhu, CH [1 ]
Li, NP [1 ]
Wen, W [1 ]
机构
[1] Hunan Univ, Coll Civil Engn, Changsha 410082, Hunan, Peoples R China
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Indoor air quality (IAQ) is affected by several factors and the level of indoor air quality is a fuzzy idea, thus how to assess indoor air quality according to these single indexes is an important problem that it is time to solve. The assessment method should express the integrative influence of these factors on indoor air quality. Based on the analysis of grey incidence, which is an important part of grey system theory, this paper assesses indoor air quality by the abundant information provided by grey incidence matrix. According to the analysis and comparison with other methods, it is clear that the grey assessment is an ideal method of assessing concerned with several parameters because the procedure is simple and the outcome is credible.
引用
收藏
页码:81 / 88
页数:8
相关论文
共 50 条
  • [1] Indoor Air Quality Assessment Based ON Grey Classification Method
    Zhang Furen
    Deng Panpan
    Xu Pai
    [J]. 2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 3910 - 3913
  • [2] Grey model of indoor air quality
    Zhu, C
    Li, N
    [J]. INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 2807 - 2812
  • [3] Uncertainty in indoor air quality and grey system method
    Zhu, Chihui
    Li, Nianping
    Re, Di
    Guan, Jun
    [J]. BUILDING AND ENVIRONMENT, 2007, 42 (04) : 1711 - 1717
  • [4] Grey interrelated evaluation of indoor air quality in buildings
    Wang, HQ
    Shi, SL
    [J]. INDOOR AND BUILT ENVIRONMENT, 1999, 8 (05) : 304 - 308
  • [5] INDOOR MATERIALS AND AIR QUALITY ASSESSMENT
    Senitkova, Ingrid
    [J]. GEOCONFERENCE ON NANO, BIO AND GREEN - TECHNOLOGIES FOR A SUSTAINABLE FUTURE, VOL II (SGEM 2014), 2014, : 207 - 212
  • [6] Indoor Air Quality Modeling and Assessment
    Bittel, C.
    Dieker, B.
    Hartman, J.
    Walbridge, K.
    Dougherty, R. L.
    [J]. ASHRAE TRANSACTIONS 2018, VOL 124, PT 2, 2018, 124 : 61 - 78
  • [7] Apply grey relating method to evaluate indoor air quality
    Han, J
    Zhang, JW
    Zhang, GQ
    [J]. BUILT ENVIRONMENT AND PUBLIC HEALTH, PROCEEDINGS, 2004, : 183 - 186
  • [8] Indoor air quality of new hotels: Grey theory approach
    Chan, Wilco
    Lee, Shuncheng
    Chan, Jazz
    Chen, Youming
    Mak, Barry
    Zheng, Cong
    Guo, Xingguo
    [J]. FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 745 - 750
  • [9] Study on Grey Clustering Model of Indoor Air Quality Indicators
    Zhu, Chihui
    Li, Nianping
    [J]. 10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 2815 - 2822
  • [10] Modeling, assessment, and control of indoor air quality
    Yang, Xudong
    Zhang, Yinping
    [J]. BUILDING AND ENVIRONMENT, 2008, 43 (03) : 237 - 237