GREY EVALUATION MODEL OF INDOOR AIR QUALITY USING A COMBINATION WEIGHTING METHOD

被引:0
|
作者
Zhang, Xutao [1 ]
Wang, Songling [1 ]
Wang, Jiangjiang [1 ]
Shi, Guohua [1 ]
机构
[1] N China Elect Power Univ, Sch Energy & Power Engn, Baoding, Peoples R China
关键词
Indoor Air Quality; Grey Evaluation Model; Evaluation Criteria; The Weights;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Indoor air quality (IAQ) is effected by many factors, such as temperature, humidity, air contaminants. The indoor air pollution can be an important risk factor for human health that is greatly paid attention. This paper provides a grey evaluation model for indoor air contaminants. In the grey relation analysis the weights is vital to the result. To obtain a credible result, the optimal weighting method is adopted that combines both the subjectivity of decision-maker and the objectivity of numerical data. As an example, the IAQ of four buildings are compared and evaluated. The assessment results show that this grey evaluation model can provide a reliable evaluation method for IAQ.
引用
收藏
页码:952 / 959
页数:8
相关论文
共 50 条
  • [1] Grey model of indoor air quality
    Zhu, C
    Li, N
    [J]. INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 2807 - 2812
  • [2] Grey interrelated evaluation of indoor air quality in buildings
    Wang, HQ
    Shi, SL
    [J]. INDOOR AND BUILT ENVIRONMENT, 1999, 8 (05) : 304 - 308
  • [3] Uncertainty in indoor air quality and grey system method
    Zhu, Chihui
    Li, Nianping
    Re, Di
    Guan, Jun
    [J]. BUILDING AND ENVIRONMENT, 2007, 42 (04) : 1711 - 1717
  • [4] Development of Weighting Scheme for Indoor Air Quality Model Using a Multi-Attribute Decision Making Method
    Piasecki, Michal
    Kostyrko, Krystyna
    [J]. ENERGIES, 2020, 13 (12)
  • [5] Apply grey relating method to evaluate indoor air quality
    Han, J
    Zhang, JW
    Zhang, GQ
    [J]. BUILT ENVIRONMENT AND PUBLIC HEALTH, PROCEEDINGS, 2004, : 183 - 186
  • [6] Indoor Air Quality Assessment Based ON Grey Classification Method
    Zhang Furen
    Deng Panpan
    Xu Pai
    [J]. 2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 3910 - 3913
  • [7] Study on Grey Clustering Model of Indoor Air Quality Indicators
    Zhu, Chihui
    Li, Nianping
    [J]. 10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 2815 - 2822
  • [8] Grey assessment of indoor air quality
    Zhu, CH
    Li, NP
    Wen, W
    [J]. PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 81 - 88
  • [9] Weighting analysis by using grey method
    Huang, Yi-Fung
    Wen, Kun-Li
    [J]. JOURNAL OF DISCRETE MATHEMATICAL SCIENCES & CRYPTOGRAPHY, 2008, 11 (01): : 33 - 58
  • [10] Comparative Study on Indoor Air Quality Evaluation Method
    Leng, Xingyang
    Jiang, Ping
    [J]. SUSTAINABLE ENVIRONMENT AND TRANSPORTATION, PTS 1-4, 2012, 178-181 : 267 - 271