μ-dDIHEN: a new micro-flow liquid sample introduction system for direct injection nebulization in ICP-MS

被引:12
|
作者
Louvat, Pascale [1 ]
Tharaud, Mickael [1 ]
Buisson, Matthieu [1 ]
Rollion-Bard, Claire [1 ]
Benedetti, Marc F. [1 ]
机构
[1] Univ Paris, CNRS, Inst Phys Globe Paris, F-75005 Paris, France
关键词
HIGH-EFFICIENCY NEBULIZER; PLASMA-MASS SPECTROMETRY; ORGANIC/HYDRO-ORGANIC MATRICES; OPTICAL-EMISSION SPECTROMETRY; BIOLOGICAL SAMPLES; CHROMATOGRAPHY; ELEMENTS; BORON; PRODUCTS; SEAWATER;
D O I
10.1039/c9ja00146h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The mu-dDIHEN allows direct nebulization of small samples into the plasma at a flow rate down to 5 mu L min(-1). It is composed of a demountable direct injection high efficiency nebulizer (d-DIHEN), a flow injection analysis (FIA) valve and a gas displacement pump (GDP) connected to a mu-mass-flow meter delivering very stable liquid flow. The system was successfully tested with sample loops of 10 and 50 mu L and for liquid flow rates between 5 and 50 mu L min(-1) on two different inductively coupled plasma mass spectrometry (ICP-MS) instruments, a sector-field-ICP-MS (SF-ICP-MS) and a multi-collector-ICP-MS (MC-ICP-MS), and for three different applications: boron isotopic ratio measurement of geological samples, multi-element analyses of natural water samples and gold nanoparticle characterization by single particle ICPMS (spICP-MS). Signal sensitivity was increasing with the liquid uptake rate of the mu-dDIHEN (and the GDP gas flow rate), but stopped increasing above 30 mu L min(-1), due to bad spray quality and poor ionization under extra-wet conditions. We successfully measured boron isotopic ratios (delta B-11) for reference material solutions with B concentrations between 10 and 200 mu g L-1; the reproducibility of the measurements depending on both the B concentration of the sample and the uptake rate: B-10 signals below 20-30 mV (with 10(11) ohms amplifiers) gave 2SD reproducibility >= 0.5 parts per thousand (n = 5). The best measurement conditions were not necessarily with the lowest uptake rate but rather at 25 mu L min(-1), allowing for higher signals. We also tested transient versus continuous measurement modes for a series of natural samples (with 10 and 50 mu L sample loops). The two modes gave fully comparable results but the transient mode allows triplicate delta B-11 measurements and is recommended for very small samples (<= 100 mu L and B content of a few ng). For multi-element analyses by SF-ICP-MS, the limits of quantification (LOQs) of the majority of the trace and ultra-trace elements were lower (up to 15 times) with the mu-dDIHEN than with a concentric nebulizer and spray chamber, due to the much lower sample volume needed. Lastly, the mu-dDIHEN is highly promising for nanoparticle (NP) characterization by spICPMS. The first measurements for gold NPs of 40 nm certified size led to a transport efficiency of 85%.
引用
收藏
页码:1553 / 1563
页数:11
相关论文
共 50 条
  • [1] ICP-MS method for Pu and Np isotopes in population monitoring by a micro-flow injection sample introduction system
    Shi, Youqing
    Dai, Xiongxin
    Li, Chunsheng
    Collins, Roxanne
    Kramer-Tremblay, Sheila
    Riopel, Remi
    Broome, Carrie
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (09) : 1708 - 1713
  • [2] The direct analysis of fuel ethanol by ICP-MS using a flow injection system coupled to an ultrasonic nebulizer for sample introduction
    Saint'Pierre, Tatiana D.
    Tormen, Luciano
    Frescura, Vera L. A.
    Curtius, Adilson J.
    Journal of Analytical Atomic Spectrometry, 2006, 21 (11): : 1340 - 1344
  • [3] The direct analysis of fuel ethanol by ICP-MS using a flow injection system coupled to an ultrasonic nebulizer for sample introduction
    Saint'Pierre, Tatiana D.
    Tormen, Luciano
    Frescura, Vera L. A.
    Curtius, Adilson J.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2006, 21 (11) : 1340 - 1344
  • [4] A convenient sample introduction system for ICP, ICP-MS, and AA
    McLaughlin, Roger
    Cheese, Paula
    Ding, Min
    Ptolemy, Adam
    Conn, April
    Brindle, Ian
    AMERICAN LABORATORY, 2006, 38 (18) : 13 - +
  • [6] ICP-MS WITH AN OSCILLATING CAPILLARY NEBULIZER FOR MICRO-FLOW LIQUID-CHROMATOGRAPHY OF SE DRUG METABOLITES
    BROWNER, RF
    WANG, LQ
    MAY, SW
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1994, 208 : 148 - ANYL
  • [7] Performance characteristics of a low volume spray chamber with a micro-flow nebulizer for ICP-MS
    Cairns, WRL
    Barbante, C
    Capodaglio, G
    Cescon, P
    Gambaro, A
    Eastgate, A
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (02) : 286 - 291
  • [8] A highly efficient sample introduction system for interfacing micro. uidic chips with ICP-MS
    Pearson, Gareth
    Greenway, Gillian
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2007, 22 (06) : 657 - 662
  • [9] Sample introduction systems for the analysis of liquid microsamples by ICP-AES and ICP-MS
    Todoli, Jose L.
    Mermet, Jean M.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2006, 61 (03) : 239 - 283
  • [10] High performance concentric nebulizer for low-flow rate liquid sample introduction to ICP-MS
    Inagaki, Kazumi
    Fujii, Shin-ichiro
    Takatsu, Akiko
    Chiba, Koichi
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2011, 26 (03) : 623 - 630