Radon exhalation rate in building materials using plastic track detectors

被引:10
|
作者
Amrani, D [1 ]
Cherouati, DE [1 ]
机构
[1] Ctr Radioprotect & Surete, Lab Dosimetrie, Algiers, Algeria
关键词
Cellulose; Radon; Building Material; Reliable Method; Track Detector;
D O I
10.1007/BF02345552
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The radon flux emitted from building material samples and from the surface of building materials could be determined using a simple and reliable method. This method was based on the use of cellulose nitrate films (LR-115 II). The samples and the detectors were placed in a closed can of known dimensions. Tracks due to alpha-particles of radon that migrate from the building material into the air space in the chamber were registered on the LR-115 film. The detectors were chemically etched in 2.5N NaOH solution at 60+/-1 degrees C for 115 minutes. Exhalation rates of various building material samples and of building surfaces of various building components were determined. The results obtained by this technique could be used to establish a database for average radon exhalation rates for all available building materials and walls or floors.
引用
收藏
页码:269 / 271
页数:3
相关论文
共 50 条
  • [41] A study of radon emitted from building materials using solid state nuclear track detectors
    Amin, Rafat M.
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2015, 8 (04) : 516 - 522
  • [42] Radon diffusion studies in some building materials using solid state nuclear track detectors
    Singh, S
    Kumar, J
    Singh, B
    Singh, J
    RADIATION MEASUREMENTS, 1999, 30 (04) : 461 - 464
  • [43] URANIUM AND RADON ESTIMATION BY PLASTIC TRACK DETECTORS
    SURI, PS
    SINGH, S
    VIRK, HS
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 1981, 19 (11) : 1131 - 1133
  • [44] Measurement of Radon exhalation rate using Solid State Nuclear Track Detector
    Singh, Lalit Mohan
    Singh, K. Y.
    Mahur, Ajay
    Kumar, Dinesh
    Gupta, Devesh
    ADVANCES IN BASIC SCIENCES (ICABS 2019), 2019, 2142
  • [45] The study of indoor radon in the urban dwellings using plastic track detectors
    Khan, M. Shakir
    Zubair, M.
    Verma, Deepak
    Naqvi, A. H.
    Azam, Ameer
    Bhardwaj, M. K.
    ENVIRONMENTAL EARTH SCIENCES, 2011, 63 (02) : 279 - 282
  • [46] The study of indoor radon in the urban dwellings using plastic track detectors
    M. Shakir Khan
    M. Zubair
    Deepak Verma
    A. H. Naqvi
    Ameer Azam
    M. K. Bhardwaj
    Environmental Earth Sciences, 2011, 63 : 279 - 282
  • [47] Radon dosimetry in typical Indian dwellings using plastic track detectors
    Kant, K
    Upadhyay, SB
    Sharma, GS
    Chakarvart, SK
    INDOOR AND BUILT ENVIRONMENT, 2006, 15 (02) : 187 - 191
  • [48] Study of radon exhalation rates from coal using solid state nuclear track detectors
    Pranjal P. Gogoi
    Debajyoti Barooah
    Journal of Radioanalytical and Nuclear Chemistry, 2022, 331 : 1959 - 1965
  • [49] Study of radon exhalation rates from coal using solid state nuclear track detectors
    Gogoi, Pranjal P.
    Barooah, Debajyoti
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2022, 331 (04) : 1959 - 1965
  • [50] Radon and thoron exhalation rate from building materials: experimental evaluations and theoretical models
    Magnoni, Mauro
    Chiaberto, Enrico
    Serena, Elena
    EUROPEAN PHYSICAL JOURNAL PLUS, 2024, 139 (01):