The study of indoor radon in the urban dwellings using plastic track detectors

被引:0
|
作者
M. Shakir Khan
M. Zubair
Deepak Verma
A. H. Naqvi
Ameer Azam
M. K. Bhardwaj
机构
[1] Aligarh Muslim University,Department of Applied Physics, Z. H. College of Engineering and Technology
来源
关键词
Radon and its progeny levels; LR-115 type II plastic track detectors; Effective dose; Life time fatality risk;
D O I
暂无
中图分类号
学科分类号
摘要
Radon and its progeny have been recognized as one of the major contributors to the natural radiation and health hazards in the human dwellings. Even lung cancer is expected if it is present in enhanced levels beyond maximum permissible limit. This paper reports the measurements of indoor radon and its progeny in the urban dwellings of the Etah district of Uttar Pradesh province in Northern India using the cellulose nitrate (LR-115 type-II) plastic track detectors. It is found that the values of radon concentration vary from 3.52 to 248.64 Bq m−3 with a standard deviation of 69.19. The values of radon progeny concentration vary from 0.38 to 26.88 mWL with a standard deviation of 7.48. The effective dose has been calculated and found to vary from 0.05 to 3.76 mSv year−1 with a standard deviation of 1.05. The lifetime fatality risk is found to vary from 0.04 × 10−4 to 2.90 × 10−4. The results have been compared with the results reported in the rural areas of the same district.
引用
下载
收藏
页码:279 / 282
页数:3
相关论文
共 50 条
  • [1] The study of indoor radon in the urban dwellings using plastic track detectors
    Khan, M. Shakir
    Zubair, M.
    Verma, Deepak
    Naqvi, A. H.
    Azam, Ameer
    Bhardwaj, M. K.
    ENVIRONMENTAL EARTH SCIENCES, 2011, 63 (02) : 279 - 282
  • [2] Measurement of indoor radon and thoron in the dwellings of Faizabad city using plastic track detectors
    Verma, Deepak
    Khan, M. Shakir
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2013, 51 (04) : 219 - 222
  • [3] Radon dosimetry in typical Indian dwellings using plastic track detectors
    Kant, K
    Upadhyay, SB
    Sharma, GS
    Chakarvart, SK
    INDOOR AND BUILT ENVIRONMENT, 2006, 15 (02) : 187 - 191
  • [4] INDOOR RADON CONCENTRATION MEASUREMENTS IN SOME SPANISH HOUSES AND DWELLINGS WITH PLASTIC NUCLEAR TRACK DETECTORS
    BAIXERAS, C
    GARCIA, I
    FERNANDEZ, F
    DOMINGO, C
    VIDALQUADRAS, A
    PIESCH, E
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1991, 19 (1-4): : 279 - 282
  • [5] A STUDY OF INDOOR RADON LEVELS IN RURAL DWELLINGS OF EZINE (CANAKKALE, TURKEY) USING SOLID-STATE NUCLEAR TRACK DETECTORS
    Orgun, Y.
    Altinsoy, N.
    Sahin, S. Y.
    Ataksor, B.
    Celebi, N.
    RADIATION PROTECTION DOSIMETRY, 2008, 131 (03) : 379 - 384
  • [6] Indoor radon measurements in dwellings of Kulu area, Himachal Pradesh, using solid state nuclear track detectors
    Singh, S
    Malhotra, R
    Kumar, J
    Singh, L
    RADIATION MEASUREMENTS, 2001, 34 (1-6) : 505 - 508
  • [7] Estimation of indoor radon and thoron in dwellings of Palakkad, Kerala, India using solid state nuclear track detectors
    Ramsiya, M.
    Joseph, Antony
    Jojo, P. J.
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2017, 10 (03) : 269 - 272
  • [8] ASSESSEMENT OF INDOOR RADON, THORON AND THEIR PROGENY IN DWELLINGS OF BAREILLY CITY OF NORTHERN INDIA USING TRACK ETCH DETECTORS
    Verma, Deepak
    Khan, M. Shakir
    ROMANIAN JOURNAL OF PHYSICS, 2014, 59 (1-2): : 172 - 182
  • [9] RADON DOSIMETRY USING PLASTIC NUCLEAR TRACK DETECTORS
    FRANK, AL
    BENTON, EV
    NUCLEAR TRACK DETECTION, 1977, 1 (3-4): : 149 - 179
  • [10] Measurement methodology for indoor radon using passive track detectors
    Espinosa, G.
    Gammage, R.B.
    Applied Radiation and Isotopes, 1993, 44 (04): : 719 - 723