INDOOR RADON CONCENTRATION MEASUREMENTS IN SOME SPANISH HOUSES AND DWELLINGS WITH PLASTIC NUCLEAR TRACK DETECTORS

被引:0
|
作者
BAIXERAS, C [1 ]
GARCIA, I [1 ]
FERNANDEZ, F [1 ]
DOMINGO, C [1 ]
VIDALQUADRAS, A [1 ]
PIESCH, E [1 ]
机构
[1] FORSCHUNGSZENTRUM JULICH, DIV HLTH PHYS, W-7500 KARLSRUHE 1, GERMANY
来源
关键词
MAKROFOL; ELECTROCHEMICAL ETCHING; ALPHA TRACKS; DOSIMETER FOR RADON; CALIBRATION FACTOR; RADON CONCENTRATION;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A passive dosemeter, based on Makrofol ED track detectors covered with aluminized Mylar, enclosed in the Karlsruhe diffussion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a Am-241 source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the NRPB Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have, also, been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented.
引用
收藏
页码:279 / 282
页数:4
相关论文
共 50 条
  • [1] The study of indoor radon in the urban dwellings using plastic track detectors
    M. Shakir Khan
    M. Zubair
    Deepak Verma
    A. H. Naqvi
    Ameer Azam
    M. K. Bhardwaj
    Environmental Earth Sciences, 2011, 63 : 279 - 282
  • [2] The study of indoor radon in the urban dwellings using plastic track detectors
    Khan, M. Shakir
    Zubair, M.
    Verma, Deepak
    Naqvi, A. H.
    Azam, Ameer
    Bhardwaj, M. K.
    ENVIRONMENTAL EARTH SCIENCES, 2011, 63 (02) : 279 - 282
  • [3] Measurement of indoor radon and thoron in the dwellings of Faizabad city using plastic track detectors
    Verma, Deepak
    Khan, M. Shakir
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2013, 51 (04) : 219 - 222
  • [4] Indoor radon measurements in dwellings of Kulu area, Himachal Pradesh, using solid state nuclear track detectors
    Singh, S
    Malhotra, R
    Kumar, J
    Singh, L
    RADIATION MEASUREMENTS, 2001, 34 (1-6) : 505 - 508
  • [5] Indoor radon concentration measurements in some dwellings of the Penisola Sorrentina, South Italy
    Quarto, Maria
    Pugliese, Mariagabriella
    Loffredo, Filomena
    Roca, Vincenzo
    RADIATION PROTECTION DOSIMETRY, 2013, 156 (02) : 207 - 212
  • [6] Radon dosimetry in typical Indian dwellings using plastic track detectors
    Kant, K
    Upadhyay, SB
    Sharma, GS
    Chakarvart, SK
    INDOOR AND BUILT ENVIRONMENT, 2006, 15 (02) : 187 - 191
  • [7] INDOOR RADON MEASUREMENTS WITH TRACK-ETCH DETECTORS
    OSWALD, RA
    ALTER, HW
    GINGRICH, JE
    HEALTH PHYSICS, 1982, 43 (01): : 122 - 122
  • [8] Indoor and soil radon measurements in Swaziland by track detectors
    Farid, SM
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 1997, 34 (01) : 29 - 36
  • [9] Indoor and soil radon measurements in Swaziland by track detectors
    Farid, S.M.
    Journal of Environmental Radioactivity, 34 (01):
  • [10] MEASUREMENTS OF RADON IN DWELLINGS WITH CR-39 TRACK DETECTORS.
    Majborn, B.
    Nuclear tracks, 1985, 12 (1-6): : 763 - 766