INDOOR RADON CONCENTRATION MEASUREMENTS IN SOME SPANISH HOUSES AND DWELLINGS WITH PLASTIC NUCLEAR TRACK DETECTORS

被引:0
|
作者
BAIXERAS, C [1 ]
GARCIA, I [1 ]
FERNANDEZ, F [1 ]
DOMINGO, C [1 ]
VIDALQUADRAS, A [1 ]
PIESCH, E [1 ]
机构
[1] FORSCHUNGSZENTRUM JULICH, DIV HLTH PHYS, W-7500 KARLSRUHE 1, GERMANY
来源
关键词
MAKROFOL; ELECTROCHEMICAL ETCHING; ALPHA TRACKS; DOSIMETER FOR RADON; CALIBRATION FACTOR; RADON CONCENTRATION;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A passive dosemeter, based on Makrofol ED track detectors covered with aluminized Mylar, enclosed in the Karlsruhe diffussion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a Am-241 source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the NRPB Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have, also, been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented.
引用
收藏
页码:279 / 282
页数:4
相关论文
共 50 条
  • [21] A STUDY OF INDOOR RADON LEVELS IN RURAL DWELLINGS OF EZINE (CANAKKALE, TURKEY) USING SOLID-STATE NUCLEAR TRACK DETECTORS
    Orgun, Y.
    Altinsoy, N.
    Sahin, S. Y.
    Ataksor, B.
    Celebi, N.
    RADIATION PROTECTION DOSIMETRY, 2008, 131 (03) : 379 - 384
  • [22] RADON MEASUREMENTS IN DWELLINGS IN RADIOACTIVE AREAS IN HIMACHAL-PRADESH, INDIA, USING LR-115 PLASTIC TRACK DETECTORS
    KUMAR, J
    MALHOTRA, R
    SINGH, J
    SINGH, S
    NUCLEAR GEOPHYSICS, 1994, 8 (06): : 573 - 576
  • [23] INDOOR RADON MEASUREMENTS WITH KODAK TRACK FILM - SOME RESULTS
    JONSSON, G
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1986, 12 (1-6): : 759 - 762
  • [24] INDOOR RADON CONCENTRATION AND RISK ASSESSMENT IN SOME DWELLINGS OF OBUASI, MINING TOWN
    Opoku-Ntim, Irene
    Andam, Aba Bentil
    Roca, Vicenzo
    Fletcher, J. J.
    Akiti, T. T.
    RADIATION PROTECTION DOSIMETRY, 2020, 188 (01) : 30 - 37
  • [25] CALIBRATION OF THE POLITRACK® SYSTEM BASED ON CR39 SOLID-STATE NUCLEAR TRACK DETECTORS FOR PASSIVE INDOOR RADON CONCENTRATION MEASUREMENTS
    Kropat, G.
    Baechler, S.
    Bailat, C.
    Barazza, F.
    Bochud, F.
    Damet, J.
    Meyer, N.
    Gruson, M. Palacios
    Butterweck, G.
    RADIATION PROTECTION DOSIMETRY, 2015, 167 (1-3) : 302 - 305
  • [26] INDOOR RADON MEASUREMENT METHODOLOGY BY SOLID-STATE NUCLEAR TRACK DETECTORS
    ESPINOSA, G
    RAMOS, S
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1992, 161 (02): : 307 - 312
  • [27] Radium concentration and radon exhalation measurements using LR-115 type II plastic track detectors
    Azam, A
    Naqvi, AH
    Srivastava, DS
    NUCLEAR GEOPHYSICS, 1995, 9 (06): : 653 - 657
  • [28] Measurement of indoor radon-thoron concentration and radon soil gas in some North Indian dwellings
    Kumar, Amit
    Chauhan, R. P.
    JOURNAL OF GEOCHEMICAL EXPLORATION, 2014, 143 : 155 - 162
  • [29] Assessment of Indoor Radon Levels in Some Parts of North India, Using Solid State Nuclear Track Detectors
    Shikha, Deep
    Singh, Tejinder Pal
    Pal, Mohinder
    ADVANCES IN BASIC SCIENCES (ICABS 2019), 2019, 2142
  • [30] Indoor radon concentration and gamma dose in Hungarian dwellings
    Nikl, I
    IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 2, 1996, : B122 - B124