Radon exhalation rate in building materials using plastic track detectors

被引:10
|
作者
Amrani, D [1 ]
Cherouati, DE [1 ]
机构
[1] Ctr Radioprotect & Surete, Lab Dosimetrie, Algiers, Algeria
关键词
Cellulose; Radon; Building Material; Reliable Method; Track Detector;
D O I
10.1007/BF02345552
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The radon flux emitted from building material samples and from the surface of building materials could be determined using a simple and reliable method. This method was based on the use of cellulose nitrate films (LR-115 II). The samples and the detectors were placed in a closed can of known dimensions. Tracks due to alpha-particles of radon that migrate from the building material into the air space in the chamber were registered on the LR-115 film. The detectors were chemically etched in 2.5N NaOH solution at 60+/-1 degrees C for 115 minutes. Exhalation rates of various building material samples and of building surfaces of various building components were determined. The results obtained by this technique could be used to establish a database for average radon exhalation rates for all available building materials and walls or floors.
引用
收藏
页码:269 / 271
页数:3
相关论文
共 50 条
  • [21] Accurate measurement of the radon exhalation rate of building materials using the closed chamber method
    Zhang, Lei
    Lei, Xing
    Guo, Qiuju
    Wang, Shanqiang
    Ma, Xinhua
    Shi, Zhilan
    JOURNAL OF RADIOLOGICAL PROTECTION, 2012, 32 (03) : 315 - 323
  • [22] Radon exhalation rate in south-east Sicily building materials
    D. Morelli
    R. Catalano
    R. Filincieri
    G. Immé
    G. Mangano
    The European Physical Journal Special Topics, 2015, 224 : 605 - 610
  • [23] Radon exhalation rate in south-east Sicily building materials
    Morelli, D.
    Catalano, R.
    Filincieri, R.
    Imme, G.
    Mangano, G.
    EUROPEAN PHYSICAL JOURNAL-SPECIAL TOPICS, 2015, 224 (04): : 605 - 610
  • [24] Measurement of radon exhalation rate in various building materials and soil samples
    Bala, Pankaj
    Kumar, Vinod
    Mehra, Rohit
    JOURNAL OF EARTH SYSTEM SCIENCE, 2017, 126 (02)
  • [25] Building materials radon exhalation rate: ERRICCA intercomparison exercise results
    Petropoulos, NP
    Anagnostakis, MJ
    Simopoulos, SE
    SCIENCE OF THE TOTAL ENVIRONMENT, 2001, 272 (1-3) : 109 - 118
  • [26] Measurement of radon exhalation rate in various building materials and soil samples
    Pankaj Bala
    Vinod Kumar
    Rohit Mehra
    Journal of Earth System Science, 2017, 126
  • [27] Phosphogypsum recycling in the building materials industry: assessment of the radon exhalation rate
    Campos, M. P.
    Costa, L. J. P.
    Nisti, M. B.
    Mazzilli, B. P.
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2017, 172 : 232 - 236
  • [28] MEASUREMENT OF RADON EXHALATION RATE FROM SOME BUILDING-MATERIALS
    KHAN, AJ
    PRASAD, R
    TYAGI, RK
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1992, 20 (04): : 609 - 610
  • [29] Study of radium and radon exhalation rate in some solid samples using solid state nuclear track detectors
    Singh, B. P.
    Pandit, B.
    Bhardwaj, V. N.
    Singh, Paramjit
    Kumar, Rajesh
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2010, 48 (07) : 493 - 495
  • [30] Study of Radium and Radon Exhalation Rate in Some Sand Samples Using Solid State Nuclear Track Detectors
    Mohamed, Amal
    Alsheddi, Tarfa. H.
    Almansour, Shaffa.
    ARAB JOURNAL OF NUCLEAR SCIENCES AND APPLICATIONS, 2015, 48 (04): : 100 - 104