An objective comparison of four digital intra-oral radiographic systems: sensitometric properties and resolution

被引:14
|
作者
Araki, K [1 ]
Endo, A [1 ]
Okano, T [1 ]
机构
[1] Showa Univ, Sch Dent, Dept Oral Radiol, Ohta Ku, Tokyo 1458515, Japan
关键词
digital radiography; dental; radiography; technology; radiologic;
D O I
10.1038/sj.dmfr.4600504
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To compare the sensitometric properties and resolution of four digital intra-oral radiographic systems. Methods: Three CCD-based systems were evaluated, RVG-4 (Trophy Radiologic, Paris, France) CDR (Schick Technologies Inc, Long Island, NY, USA) and Dixel (Morita, Kyoto, Japan) and a photostimulable phosphor system (Digora, Soredex-Orion, Helsinki, Finland). The sensitometric properties were determined by measuring the gray levels at increasing exposures without making ally gray-scale adjustments. MTF was measured using images of a 10 mu m width slit inclined to the long and short axes of the detectors. Results: The CCD-based systems showed a linear relationship between exposure and gray level although there were some differences in sensitivity. In RVG-4, the gray level saturated at a lower exposure. Digora showed a logarithmic relationship at uniform exposure. However, there was a linear relationship when it was exposed below the calibration dose. The MTF was highest with RVG-4 and the lowest with the Digora. Conclusions: Each system has its own specific properties; RVG-4 has the highest resolution with the narrowest latitude: whereas Digora has the wider latitude but the lowest resolution.
引用
收藏
页码:76 / 80
页数:5
相关论文
共 50 条
  • [31] Effect of display monitor devices on intra-oral radiographic caries diagnosis
    Araki, Kazuyuki
    Fujikura, Mamiko
    Sano, Tsukasa
    CLINICAL ORAL INVESTIGATIONS, 2015, 19 (08) : 1875 - 1879
  • [32] Comparison of three methods of intra-oral antisepsis.
    Barros, VMR
    Ito, IY
    Azevedo, RVP
    Morello, D
    Rosateli, PA
    JOURNAL OF DENTAL RESEARCH, 1996, 75 (05) : 1115 - 1115
  • [33] Application of Intra-Oral Dental Scanners in the Digital Workflow of Implantology
    van der Meer, Wicher J.
    Andriessen, Frank S.
    Wismeijer, Daniel
    Ren, Yijin
    PLOS ONE, 2012, 7 (08):
  • [34] Comparison of imaging properties of several digital radiographic systems
    Amendolia, SR
    Bottigli, U
    Ceccopieri, A
    Delogu, P
    Dipasquale, G
    Fantacci, ME
    Marchi, A
    Marzulli, VM
    Oliva, P
    Rosso, V
    Stefanini, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 466 (01): : 95 - 98
  • [35] Comparison of three intra-oral storage phosphor systems using subjective image quality
    Kitagawa, H
    Farman, AG
    Scheetz, JP
    Brown, WP
    Lewis, J
    Benefiel, M
    Kuroyanagi, K
    DENTOMAXILLOFACIAL RADIOLOGY, 2000, 29 (05) : 272 - 276
  • [36] COMPARISON OF INTRA-ORAL LONG-CONE PARALLELING RADIOGRAPHIC SURVEYS AND ORTHOPANTOMOGRAPHS WITH SPECIAL REFERENCE TO THE BONE HEIGHT
    ADRIAENS, PA
    DEBOEVER, J
    VANDEVELDE, F
    JOURNAL OF ORAL REHABILITATION, 1982, 9 (04) : 355 - 365
  • [37] EFFECT OF RADIOGRAPHIC TECHNIQUE UPON PREDICTION OF TOOTH LENGTH IN INTRA-ORAL RADIOGRAPHY
    BHAKDINARONK, A
    MANSONHING, LR
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1981, 51 (01): : 100 - 107
  • [38] Testing the erosive properties of drinks by intra-oral appliances
    Gordon, PH
    Rugg-Gunn, AJ
    McCabe, JF
    Stephenson, G
    JOURNAL OF DENTAL RESEARCH, 2001, 80 (04) : 1145 - 1145
  • [39] DENSITOMETRIC EVALUATION OF INTRA-ORAL RADIOGRAPHIC FILM-PROCESSING SOLUTION COMBINATIONS
    SWART, TJP
    SEELIGER, JE
    JOURNAL OF DENTAL RESEARCH, 1989, 68 (04) : 724 - 724
  • [40] Comparison of visual shade determination and an intra-oral dental colourimeter
    Yilmaz, B.
    Karaagaclioglu, L.
    JOURNAL OF ORAL REHABILITATION, 2008, 35 (10) : 789 - 794