An objective comparison of four digital intra-oral radiographic systems: sensitometric properties and resolution

被引:14
|
作者
Araki, K [1 ]
Endo, A [1 ]
Okano, T [1 ]
机构
[1] Showa Univ, Sch Dent, Dept Oral Radiol, Ohta Ku, Tokyo 1458515, Japan
关键词
digital radiography; dental; radiography; technology; radiologic;
D O I
10.1038/sj.dmfr.4600504
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To compare the sensitometric properties and resolution of four digital intra-oral radiographic systems. Methods: Three CCD-based systems were evaluated, RVG-4 (Trophy Radiologic, Paris, France) CDR (Schick Technologies Inc, Long Island, NY, USA) and Dixel (Morita, Kyoto, Japan) and a photostimulable phosphor system (Digora, Soredex-Orion, Helsinki, Finland). The sensitometric properties were determined by measuring the gray levels at increasing exposures without making ally gray-scale adjustments. MTF was measured using images of a 10 mu m width slit inclined to the long and short axes of the detectors. Results: The CCD-based systems showed a linear relationship between exposure and gray level although there were some differences in sensitivity. In RVG-4, the gray level saturated at a lower exposure. Digora showed a logarithmic relationship at uniform exposure. However, there was a linear relationship when it was exposed below the calibration dose. The MTF was highest with RVG-4 and the lowest with the Digora. Conclusions: Each system has its own specific properties; RVG-4 has the highest resolution with the narrowest latitude: whereas Digora has the wider latitude but the lowest resolution.
引用
收藏
页码:76 / 80
页数:5
相关论文
共 50 条
  • [21] Evaluation of intra-oral radiographic film quality at the Oral Health Centre - UWC
    Crombie, K
    Parker, ME
    JOURNAL OF DENTAL RESEARCH, 1996, 75 (05) : 1307 - 1307
  • [22] An intra-oral comparison of stannous fluoride dentifrices
    Hogan, MM
    Wefel, JS
    Donly, KJ
    JOURNAL OF DENTAL RESEARCH, 1996, 75 : 1406 - 1406
  • [23] A Comparison of Human Raters and an Intra-oral Spectrophotometer
    Browning, W. D.
    Chan, D. C.
    Blalock, J. S.
    Brackett, M. G.
    OPERATIVE DENTISTRY, 2009, 34 (03) : 337 - 343
  • [24] Dependency of dose response of five charge-coupled device-based digital intra-oral radiographic systems on tube voltage
    Nishikawa, K
    Shibuya, H
    Wakoh, M
    Kuoryanagi, K
    DENTOMAXILLOFACIAL RADIOLOGY, 1999, 28 (06) : 364 - 367
  • [25] Efficacy of digital intra-oral radiography in clinical dentistry
    Versteeg, CH
    Sanderink, GCH
    vanderStelt, PF
    JOURNAL OF DENTISTRY, 1997, 25 (3-4) : 215 - 224
  • [26] MTF of digital radiography using intra-oral sensor
    Araki, K
    Hyodo, R
    Endo, A
    Harada, Y
    Okano, T
    CAR '98 - COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1998, 1165 : 937 - 937
  • [27] A COMPARISON OF INTRA-ORAL AND EXTRA-ORAL RADIOLOGICAL TECHNOLOGY
    AKER, F
    SEROWSKI, A
    BAILEY, GL
    MILITARY MEDICINE, 1981, 146 (11) : 803 - 806
  • [28] Effect of display monitor devices on intra-oral radiographic caries diagnosis
    Kazuyuki Araki
    Mamiko Fujikura
    Tsukasa Sano
    Clinical Oral Investigations, 2015, 19 : 1875 - 1879
  • [29] A Standardized Approach to Extra-Oral and Intra-Oral Digital Photography
    Ong, Jun Ming Darrell
    Crasto, Gazelle Jean
    Anwar, Erica Jade
    Brooke, Rachel
    Kang, Philip
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2022, (185):
  • [30] IMAGING PROPERTIES OF INTRA-ORAL DENTAL XERORADIOGRAPHY
    GRATT, BM
    WHITE, SC
    SICKLES, EA
    JEROMIN, LS
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1979, 99 (05): : 805 - 809