Calculation of a pencil beam kernel from measured photon beam data

被引:68
|
作者
Storchi, PRM [1 ]
van Battum, LJ [1 ]
Woudstra, E [1 ]
机构
[1] Univ Rotterdam Hosp, Dr Daniel Den Hoed Canc Ctr, NL-3008 AE Rotterdam, Netherlands
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1999年 / 44卷 / 12期
关键词
D O I
10.1088/0031-9155/44/12/305
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Usually, pencil beam kernels for photon beam calculations are obtained by Monte Carlo calculations. In this paper, we present a method to derive a pencil beam kernel from measured beam data, i.e. central axis depth doses, phantom scatter factors and off-axis ratios. These data are usually available in a radiotherapy planning system. The differences from other similar works are: (a) the central part of the pencil beam is derived from the measured penumbra of large fields and (b) the dependence of the primary photon fluence on the depth caused by beam hardening in the phantom is taken into account. The calculated pencil beam will evidently be influenced by the methods and instruments used for measurement of the basic data set. This is of particular importance for an ac curate prediction of the absorbed dose delivered by small fields. Comparisons with measurements show that the accuracy of the calculated dose distributions fits well in a 2% error interval in the open part of the field, and in a 2 mm isodose shift in the penumbra region.
引用
收藏
页码:2917 / 2928
页数:12
相关论文
共 50 条
  • [1] A PENCIL BEAM MODEL FOR PHOTON DOSE CALCULATION
    AHNESJO, A
    SAXNER, M
    TREPP, A
    MEDICAL PHYSICS, 1992, 19 (02) : 263 - 273
  • [2] Photon pencil kernel parameterisation based on beam quality index
    Nyholm, Tufve
    Olofsson, Jorgen
    Ahnesjo, Anders
    Karlsson, Mikael
    RADIOTHERAPY AND ONCOLOGY, 2006, 78 (03) : 347 - 351
  • [3] Calculation and Verification of a Planar Pencil Beam Kernel Through the Hankel Transform of Measured OARs for a Radiosurgery System with Cones
    Vargas Verdesoto, Milton X.
    Alvarez Romero, Jose T.
    ELEVENTH MEXICAN SYMPOSIUM ON MEDICAL PHYSICS, 2010, 1310 : 150 - +
  • [4] Calculation of the absorbed dose distribution due to irregularly shaped photon beams using pencil beam kernels derived from basic beam data
    Storchi, P
    Woudstra, E
    PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (04): : 637 - 656
  • [5] Intensity modulated dose calculation with an improved experimental pencil-beam kernel
    Diego Azcona, Juan
    Burguete, Javier
    MEDICAL PHYSICS, 2010, 37 (09) : 4634 - 4642
  • [6] Modelling lateral beam quality variations in pencil kernel based photon dose calculations
    Nyholm, T.
    Olofsson, J.
    Ahnesjo, A.
    Karlsson, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (16): : 4111 - 4118
  • [7] A PENCIL BEAM ALGORITHM FOR HELIUM ION BEAM DOSE CALCULATION
    Fuchs, H.
    Stroebele, J.
    Schreiner, T.
    Georg, D.
    RADIOTHERAPY AND ONCOLOGY, 2012, 102 : S39 - S40
  • [8] Simplified Pencil Beam Kernel For Unfiltered Energies
    Erturk, M.
    Kocar, C.
    Tombakoglu, M.
    Gurdalli, S.
    MEDICAL PHYSICS, 2015, 42 (06) : 3497 - 3497
  • [9] Application of measured pencil beam parameters for electron beam model evaluation
    Higgins, PD
    Gerbi, BJ
    Khan, FM
    MEDICAL PHYSICS, 2003, 30 (04) : 514 - 520
  • [10] Deflection Calculation for Beam-type Structures from Measured Strain Data
    Flajs, Zeljko
    Veg, Emil
    Gubeljak, Nenad
    Sinikovic, Goran
    TEHNICKI VJESNIK-TECHNICAL GAZETTE, 2020, 27 (02): : 665 - 670